Hemodialysis taping styles and their effect on reducing the chance of venous needle dislodgement.

VND dialysis hemodialysis vascular access venous needle dislodgement

Journal

Seminars in dialysis
ISSN: 1525-139X
Titre abrégé: Semin Dial
Pays: United States
ID NLM: 8911629

Informations de publication

Date de publication:
05 2021
Historique:
pubmed: 19 12 2020
medline: 29 10 2021
entrez: 18 12 2020
Statut: ppublish

Résumé

Vascular access complications are common among hemodialysis patients, although most are not immediately life-threatening. However, inconsistent taping techniques and incompatible detection mechanisms may lead to venous needle dislodgement (VND), which can lead to catastrophic blood loss. Taping technique does not always meet the recommended best practice and there may be no available protocol for new staff. Three commonly used taping patterns (the Chevron, butterfly, and overlapping styles) were tested in a mechanical engineering laboratory to determine the forces that each method was capable of withstanding. While all taping styles were confirmed to have an adhesive force stronger than the inherent force from the venous jet flow of blood, the overlapping style was found to have limited capability beyond this minimum criterion. Both the butterfly and Chevron styles demonstrated excellent holding capability, with elongation of dislodgement particularly noted for the butterfly style, and slightly stronger hold noted for the Chevron style. The Chevron style may be better suited to lateral movements from all directions, due to the taping direction. We recommend that either the Chevron or butterfly style is used for dialysis needle taping, with the butterfly better suited to home dialysis (where monitors may be used) and the Chevron better suited for in-care patients who may present erratic movements. The overlapping style is not recommended for use.

Identifiants

pubmed: 33336846
doi: 10.1111/sdi.12944
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

218-223

Informations de copyright

© 2020 Wiley Periodicals LLC.

Références

Levin A, Tonelli M, Bonventre J, et al. Global kidney health 2017 and beyond: a roadmap for closing gaps in care, research, and policy. Lancet. 2017;390:1888.
Liyanage T, Ninomiya T, Jha V, et al. Worldwide access to treatment for end-stage kidney disease: a systematic review. Lancet. 2015;385:1975.
United States Renal Data System. Healthy People 2020,Medicare expenditures,dialysis providers,end-stage renal disease,international comparisons,mortality",palliative care,pediatric ESRD,transplantation. United States Annu Data Rep. 2015;2:227-238.
Axley B, Speranza-Reid J, Williams H. Venous needle dislodgement in patients on hemodialysis. Nephrol. Nurs. J.. 2012;39.
Lee A, Penn K, Hand C, et al. Taping of dialysis needles and securing of lines for patients on haemodialysis-a quality project. Renal Soc Aust J. 2016;12:82.
Jose MD, Marshall MR, Read G, et al. Fatal dialysis vascular access haemorrhage. Am J Kidney Dis. 2017;70:570.
Kear T, Ulrich B. Patient safety and patient safety culture in nephrology nurse practice settings: Issues, solutions, and best practices. Nephrol Nurs J. 2015;42:113.
Ribitsch W, Schilcher G, Hafner-Giessauf H, et al. Prevalence of detectable venous pressure drops expected with venous needle dislodgement. In: Seminars in Dialysis. Winston-Salem: Wiley Online Library. 2014, vol. 27, pp. 507-511.
Garrick R, Morey R. Dialysis facility safety: processes and opportunities. In: Seminars in Dialysis. Winston-Salem: Wiley Online Library. 2015, vol. 28, pp. 514-524.
Hawley CM, Jeffries J, Nearhos J, Van Eps C. Complications of home hemodialysis. Hemodial Int. 2008;12:S21.
Huang P-T, Wu J-X, Li C-M, Lin C-H, IET Science. Integration of wireless flexible sensor and virtual internal impedance model for blood leakage detection during haemodialysis. Meas Technol. 2018;12:617.
Ou Y-K, Wu M-J, Ciou W-S, Du Y-C. A clinical trial of the effect of a blood leakage detection device for patients during hemodialysis. Int J Environ Res Public Health. 2019;16:2388.
Wu J-X, Huang P-T, Li C-M, Lin C-H. 13 Bidirectional hetero-associative memory network with flexible sensors and cloud computing for blood leakage detection in intravenous and dialysis therapy. IEEE Trans Emerg Top Comput Intell. 2018;2:298.
Saha M, Allon M. Diagnosis, treatment, and prevention of hemodialysis emergencies. Clin J Am Soc Nephrol. 2017;12:357.
Van Waeleghem J-P, Chamney M, Lindley EJ, Pancírová J. Venous needle dislodgement: how to minimise the risks. J Renal Care. 2008;34:163.

Auteurs

Dominic Y F Chan (DYF)

School of Mechanical & Manufacturing Engineering, University of New South Wales, Sydney, NSW, Australia.

Scott Dobson (S)

Clinical Nurse Specialist, Renal Dialysis Unit, Shoalhaven District Memorial Hospital, Nowra, NSW, Australia.

Tracie Barber (T)

School of Mechanical & Manufacturing Engineering, University of New South Wales, Sydney, NSW, Australia.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH