The bleeding risk after endoscopic ultrasound-guided puncture of pancreatic masses.
Bleeding
adverse events
endoscopic ultrasound
fine needle aspiration
fine needle biopsy
Journal
Scandinavian journal of gastroenterology
ISSN: 1502-7708
Titre abrégé: Scand J Gastroenterol
Pays: England
ID NLM: 0060105
Informations de publication
Date de publication:
Feb 2021
Feb 2021
Historique:
pubmed:
24
12
2020
medline:
19
8
2021
entrez:
23
12
2020
Statut:
ppublish
Résumé
Although EUS-fine-needle aspiration (FNA) is considered to be safe, there are limited studies on adverse events of fine-needle biopsy (FNB). To compare the bleeding rate of EUS-FNA and EUS-FNB of solid and cystic pancreatic masses. Our retrospective study included EUS-FNA/FNB of solid and cystic pancreatic masses performed between 02/2017-03/2019 in Klinikum Klagenfurt and 11/2018-03/2019 in University Hospital St. Pölten, Austria. Minor bleeding was defined as an event with a duration of more than 1 min, no need for intervention, large coagulum on the puncture site, or decrease in hemoglobin ≥1.5 g/dL (but <2 g/dL). Major bleeding was defined as a reduction in hemoglobin level ≥2 g/dL, need for red cell transfusions, or interventional hemostasis. About 202 patients were biopsied in that period (141 solid, 61cystic pancreatic masses). FNA needle was used in 54.6% of cases with solid pancreatic masses and 73.7% of cysts. Bleeding with hemodynamic instability was not observed in our cohort. In pancreatic cysts, minor bleeding was observed in 8.2% of cases and was associated with the use of FNB needles and lower platelet count. In solid tumors, one major bleeding (0.7%) from a duodenal vessel occurred and was immediately treated with hemoclip. In this group, minor bleeding was observed in 15.6% of cases. Overall, the bleeding rate correlates with the use of FNB needles. Use of EUS-FNB needles increases the rate of minor bleeding for both solid and cystic pancreatic tumors, while major bleeding is a rare occurrence, irrespective of the needle type.
Sections du résumé
BACKGROUND
BACKGROUND
Although EUS-fine-needle aspiration (FNA) is considered to be safe, there are limited studies on adverse events of fine-needle biopsy (FNB).
AIM
OBJECTIVE
To compare the bleeding rate of EUS-FNA and EUS-FNB of solid and cystic pancreatic masses.
METHODS
METHODS
Our retrospective study included EUS-FNA/FNB of solid and cystic pancreatic masses performed between 02/2017-03/2019 in Klinikum Klagenfurt and 11/2018-03/2019 in University Hospital St. Pölten, Austria. Minor bleeding was defined as an event with a duration of more than 1 min, no need for intervention, large coagulum on the puncture site, or decrease in hemoglobin ≥1.5 g/dL (but <2 g/dL). Major bleeding was defined as a reduction in hemoglobin level ≥2 g/dL, need for red cell transfusions, or interventional hemostasis.
RESULTS
RESULTS
About 202 patients were biopsied in that period (141 solid, 61cystic pancreatic masses). FNA needle was used in 54.6% of cases with solid pancreatic masses and 73.7% of cysts. Bleeding with hemodynamic instability was not observed in our cohort. In pancreatic cysts, minor bleeding was observed in 8.2% of cases and was associated with the use of FNB needles and lower platelet count. In solid tumors, one major bleeding (0.7%) from a duodenal vessel occurred and was immediately treated with hemoclip. In this group, minor bleeding was observed in 15.6% of cases. Overall, the bleeding rate correlates with the use of FNB needles.
CONCLUSION
CONCLUSIONS
Use of EUS-FNB needles increases the rate of minor bleeding for both solid and cystic pancreatic tumors, while major bleeding is a rare occurrence, irrespective of the needle type.
Identifiants
pubmed: 33355007
doi: 10.1080/00365521.2020.1863458
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM