Accuracy of visual on-site evaluation (Vose) In predicting the adequacy of Eus-guided fine needle biopsy: A single center prospective study.
Accuracy
Endoscopic ultrasound fine needle biopsy
Save passes
visual evaluation of specimen
Journal
Pancreatology : official journal of the International Association of Pancreatology (IAP) ... [et al.]
ISSN: 1424-3911
Titre abrégé: Pancreatology
Pays: Switzerland
ID NLM: 100966936
Informations de publication
Date de publication:
Jan 2021
Jan 2021
Historique:
received:
01
08
2020
revised:
26
09
2020
accepted:
14
12
2020
pubmed:
29
12
2020
medline:
21
10
2021
entrez:
28
12
2020
Statut:
ppublish
Résumé
Endoscopic ultrasound is the standard procedure for the diagnosis of pancreatic lesions and new needles have been developed to improve tissue acquisition (FNB). Rapid onset evaluation (ROSE) decreases the number of needle passes but is not always available. We introduced an easy and rapid method of direct classification of EUS-FNB sample namely Visual on-site evaluation (VOSE). To assess the accuracy of VOSE in predicting the histological adequacy of specimens. To evaluate the diagnostic power of FNB and the rate of core tissue obtained. Prospective single center study on patients with pancreatic lesions that underwent EUS-FNB. VOSE parameters were presence of blood, macroscopic visible core (MVC), number, color and length of specimen. The association between VOSE tool and histological adequacy was assessed. Fisher's exact test and Student's t-test used to compare categorical and continuous variables. Logistic regression analysis was used to assess association between variables. 99 patients (58.6% male; mean age 68.4 ± 10) enrolled, including 102 lesions. Total number of passes was 358 with median number of 4 (range, 2-4). The 92.7% of samples were adequate and it was higher with the 22-G needle than with 25G (96.5% vs 89.2% p 0.01). VOSE "red-mixed specimen" was associated with a higher probability of histological adequacy (OR 2.39 95% CI 1.03-5.42 p = 0.04). The VOSE tool "red-mixed specimen" can be used to predict the histological adequacy and guide the number of needle passes. Overall, FNB provides a high rate of adequate and diagnostic specimen and high rate of core tissue especially with the 22G needle.
Identifiants
pubmed: 33358086
pii: S1424-3903(20)30871-1
doi: 10.1016/j.pan.2020.12.011
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
312-317Informations de copyright
Copyright © 2020 IAP and EPC. Published by Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest All authors have no conflict of interest.