Improving MiniHip femoral prosthesis positioning using a cross-laser projection system in total hip arthroplasty by an anterolateral supine approach.

MiniHip anterolateral supine approach hip arthroplasty minimally invasive surgery patient-specific short stem

Journal

The international journal of medical robotics + computer assisted surgery : MRCAS
ISSN: 1478-596X
Titre abrégé: Int J Med Robot
Pays: England
ID NLM: 101250764

Informations de publication

Date de publication:
Apr 2021
Historique:
received: 06 08 2020
revised: 20 11 2020
accepted: 21 12 2020
pubmed: 29 12 2020
medline: 21 7 2021
entrez: 28 12 2020
Statut: ppublish

Résumé

The authors developed a cross-laser projection system (CLP) to place a femoral neck-sparing short stem using the minimally invasive anterolateral supine approach in total hip arthroplasty. This study aimed to verify the utility of CLP. Thirty joints were assessed with the MiniHip (Corin). The authors compared femoral component implantation with a patient-specific femoral osteotomy guide (PSG) for the femoral neck-cut (PSG group), with the CLP attached to the rasp handle to irradiate the cross-laser to the target of PSG (CLP group), and without PSG or CLP (control group). In the CLP group, the positional deviation of anteversion, anterior/posterior tilt and varus/valgus placement of the stem postoperatively were 1.8° ± 0.2°, 2.0° ± 2.0° and 2.0° ± 0.1°, respectively. The positional deviation of anteversion (p < 0.001) and anterior/posterior tilt (p = 0.036) were significantly smaller than those in the other groups. CLP improves the accuracy of MiniHip femoral prosthesis placement.

Sections du résumé

BACKGROUND BACKGROUND
The authors developed a cross-laser projection system (CLP) to place a femoral neck-sparing short stem using the minimally invasive anterolateral supine approach in total hip arthroplasty. This study aimed to verify the utility of CLP.
METHODS METHODS
Thirty joints were assessed with the MiniHip (Corin). The authors compared femoral component implantation with a patient-specific femoral osteotomy guide (PSG) for the femoral neck-cut (PSG group), with the CLP attached to the rasp handle to irradiate the cross-laser to the target of PSG (CLP group), and without PSG or CLP (control group).
RESULTS RESULTS
In the CLP group, the positional deviation of anteversion, anterior/posterior tilt and varus/valgus placement of the stem postoperatively were 1.8° ± 0.2°, 2.0° ± 2.0° and 2.0° ± 0.1°, respectively. The positional deviation of anteversion (p < 0.001) and anterior/posterior tilt (p = 0.036) were significantly smaller than those in the other groups.
CONCLUSIONS CONCLUSIONS
CLP improves the accuracy of MiniHip femoral prosthesis placement.

Identifiants

pubmed: 33369069
doi: 10.1002/rcs.2214
pmc: PMC7988605
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e2214

Informations de copyright

© 2021 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons Ltd.

Références

Expert Rev Med Devices. 2009 Sep;6(5):507-14
pubmed: 19751123
Hip Int. 2018 Nov;28(6):636-641
pubmed: 29716401
Int J Med Robot. 2013 Jun;9(2):223-9
pubmed: 23460526
Clin Orthop Relat Res. 2010 Apr;468(4):1088-95
pubmed: 19629605
Int Orthop. 2015 Dec;39(12):2315-21
pubmed: 25787684
Orthopedics. 2017 Mar 1;40(2):e374-e377
pubmed: 27841929
Clin Orthop Relat Res. 2004 Dec;(429):248-55
pubmed: 15577495
Int Orthop. 2013 Jun;37(6):1063-8
pubmed: 23512603
Musculoskelet Surg. 2015 Apr;99(1):11-8
pubmed: 25304253
Int Orthop. 2019 Aug;43(8):1807-1814
pubmed: 30135983
J Arthroplasty. 2013 Oct;28(9):1648-53
pubmed: 23602234
J Arthroplasty. 2014 Mar;29(3):590-5
pubmed: 24034907
Knee. 2019 Dec;26(6):1421-1428
pubmed: 31519328
Orthopedics. 2015 Mar;38(3 Suppl):S6-13
pubmed: 25826635
J Arthroplasty. 2014 Sep;29(9):1709-12
pubmed: 24961893
J Arthroplasty. 2013 Dec;28(10):1806-10
pubmed: 23523215
Ann Transl Med. 2016 Apr;4(7):126
pubmed: 27162776
Clin Orthop Relat Res. 2011 Feb;469(2):423-8
pubmed: 20852974
Acta Orthop. 2009 Oct;80(5):538-44
pubmed: 19916685
Clin Orthop Surg. 2013 Mar;5(1):1-9
pubmed: 23467021
Int Orthop. 2007 Aug;31 Suppl 1:S7-11
pubmed: 17668206
Int J Med Robot. 2017 Sep;13(3):
pubmed: 28480999
J Orthop. 2018 Mar 17;15(2):379-383
pubmed: 29881158
J Orthop. 2014 Sep 11;11(4):166-9
pubmed: 25561750
J Arthroplasty. 2013 Apr;28(4):631-6
pubmed: 23498350
J Bone Joint Surg Am. 2011 Mar 2;93(5):500-9
pubmed: 21368083
Comput Aided Surg. 2013;18(5-6):187-94
pubmed: 23862732
J Arthroplasty. 2011 Aug;26(5):674-9
pubmed: 20870379
Bone Joint J. 2019 May;101-B(5):502-511
pubmed: 31037973

Auteurs

Hideki Fujii (H)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Tetsuo Hayama (T)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Toshiomi Abe (T)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Motoi Takahashi (M)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Yohei Matsushita (Y)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Ryuichi Sato (R)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Takuya Otani (T)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Mitsuru Saito (M)

Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH