Target registration error reduction for percutaneous abdominal intervention.

3rd order registration circuits Breathing motion compensation Deformation field Elastic body spline Reduction of target registration error

Journal

Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
ISSN: 1879-0771
Titre abrégé: Comput Med Imaging Graph
Pays: United States
ID NLM: 8806104

Informations de publication

Date de publication:
01 2021
Historique:
received: 23 06 2020
revised: 10 11 2020
accepted: 29 11 2020
pubmed: 30 12 2020
medline: 26 10 2021
entrez: 29 12 2020
Statut: ppublish

Résumé

A real-time methodology that finds spatio-temporal correspondence between the positions of the target point in the pre-treatment 3DCT image and during the procedure was proposed. It based on minimizing the target registration error in III tier registration circuits. Particle Swarm Optimization and Differential Evaluation were used to find optimal values of Elastic Body Spline parameters in the generation of abdominal deformation field. Different transformation classes have been tested: rigid, affine, Thin Plate Spline, Elastic Body Spline. The lowest TRE was obtained for the swarm optimization algorithm - differential evolution for the rigid and affine version: 3.47 and 3.73 mm, respectively.

Identifiants

pubmed: 33373971
pii: S0895-6111(20)30134-8
doi: 10.1016/j.compmedimag.2020.101839
pii:
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

101839

Informations de copyright

Copyright © 2020 Elsevier Ltd. All rights reserved.

Auteurs

Mateusz Bas (M)

Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta, 41-800, Zabrze, Poland.

Krzysztof Król (K)

Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta, 41-800, Zabrze, Poland.

Dominik Spinczyk (D)

Silesian University of Technology, Faculty of Biomedical Engineering, 40 Roosevelta, 41-800, Zabrze, Poland. Electronic address: dspinczyk@polsl.pl.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH