Continuous Glucose and Heart Rate Monitoring in Young People with Type 1 Diabetes: An Exploratory Study about Perspectives in Nocturnal Hypoglycemia Detection.

flash glucose monitoring heart rate variability nocturnal hypoglycemia type 1 diabetes

Journal

Metabolites
ISSN: 2218-1989
Titre abrégé: Metabolites
Pays: Switzerland
ID NLM: 101578790

Informations de publication

Date de publication:
24 Dec 2020
Historique:
received: 24 11 2020
revised: 21 12 2020
accepted: 22 12 2020
entrez: 30 12 2020
pubmed: 31 12 2020
medline: 31 12 2020
Statut: epublish

Résumé

A combination of information from blood glucose (BG) and heart rate (HR) measurements has been proposed to investigate the HR changes related to nocturnal hypoglycemia (NH) episodes in pediatric subjects with type 1 diabetes (T1D), examining whether they could improve hypoglycemia prediction. We enrolled seventeen children and adolescents with T1D, monitored on average for 194 days. BG was detected by flash glucose monitoring devices, and HR was measured by wrist-worn fitness trackers. For each subject, we compared HR values recorded in the hour before NH episodes (before-hypoglycemia) with HR values recorded during sleep intervals without hypoglycemia (no-hypoglycemia). Furthermore, we investigated the behavior after the end of NH. Nine participants (53%) experienced at least three NH. Among these nine subjects, six (67%) showed a statistically significant difference between the before-hypoglycemia HR distribution and the no-hypoglycemia HR distribution. In all these six cases, the before-hypoglycemia HR median value was higher than the no-hypoglycemia HR median value. In almost all cases, HR values after the end of hypoglycemia remained higher compared to no-hypoglycemia sleep intervals. This exploratory study support that HR modifications occur during NH in T1D subjects. The identification of specific HR patterns can be helpful to improve NH detection and prevent fatal events.

Identifiants

pubmed: 33374113
pii: metabo11010005
doi: 10.3390/metabo11010005
pmc: PMC7824609
pii:
doi:

Types de publication

Journal Article

Langues

eng

Références

Diabetes Care. 2010 Feb;33(2):434-41
pubmed: 20103559
Arch Dis Child. 1969 Jun;44(235):291-303
pubmed: 5785179
Diabetes Metab. 2018 Sep;44(4):313-319
pubmed: 29602622
Diabetes Obes Metab. 1999 May;1(3):151-8
pubmed: 11220293
Endocrinol Metab Clin North Am. 2010 Sep;39(3):641-54
pubmed: 20723825
Arch Dis Child. 1970 Feb;45(239):13-23
pubmed: 5440182
Curr Med Res Opin. 2016 Sep;32(9):1479-86
pubmed: 26959277
Diabetes. 2013 Oct;62(10):3570-81
pubmed: 23835337
Europace. 2008 Jul;10(7):860-7
pubmed: 18534966
Curr Diab Rep. 2013 Oct;13(5):669-78
pubmed: 23912765
Physiol Meas. 2019 Sep 03;40(8):085004
pubmed: 31357185
Sensors (Basel). 2020 Mar 19;20(6):
pubmed: 32204318
Diabet Med. 1999 Sep;16(9):782-5
pubmed: 10510957
Diabet Med. 2017 Jan;34(1):56-63
pubmed: 26996105
Comput Methods Programs Biomed. 2015 Oct;121(3):175-88
pubmed: 26120073
Horm Res Paediatr. 2018;89(3):189-199
pubmed: 29587254
Diabetes Technol Ther. 2017 Feb;19(2):91-95
pubmed: 28118049
Curr Diab Rep. 2016 Sep;16(9):88
pubmed: 27515311
Diabet Med. 1999 Aug;16(8):623-5
pubmed: 10477205
Int J Clin Pract Suppl. 2002 Jul;(129):27-32
pubmed: 12166602
Endocrinol Metab Clin North Am. 2018 Mar;47(1):65-79
pubmed: 29407057
QJM. 2009 Sep;102(9):603-7
pubmed: 19574471
Diabetes Res Clin Pract. 2019 Nov;157:107875
pubmed: 31586660
Diabetes Care. 2005 Oct;28(10):2384-7
pubmed: 16186267
Diabetes Res Clin Pract. 2019 Nov;157:107842
pubmed: 31518658
J Diabetes Sci Technol. 2019 Nov;13(6):1044-1053
pubmed: 31595784
Diabetes Technol Ther. 2016 Jun;18(6):366-76
pubmed: 27258123
Issues Compr Pediatr Nurs. 2013;36(1-2):98-119
pubmed: 23597278
Diabetologia. 2009 Jan;52(1):42-5
pubmed: 18972096
J Diabetes Complications. 2014 Sep-Oct;28(5):585-7
pubmed: 24972763
Diabetes Ther. 2018 Apr;9(2):449-492
pubmed: 29508275
Diabet Med. 1997 Jan;14(1):82-5
pubmed: 9017359
Int J Cardiol. 2010 Jan 7;138(1):91-3
pubmed: 18676043
Pediatr Diabetes. 2008 Oct;9(5):504-7
pubmed: 18503499
Pediatr Diabetes. 2019 Aug;20(5):494-509
pubmed: 30932298
J Diabetes Sci Technol. 2019 Nov;13(6):1178-1179
pubmed: 31364406
Diabet Med. 1999 Aug;16(8):626-31
pubmed: 10477206
Acta Diabetol. 2015 Aug;52(4):801-7
pubmed: 25585594
Acta Diabetol. 2017 Mar;54(3):251-256
pubmed: 27933514
Sensors (Basel). 2019 Dec 24;20(1):
pubmed: 31878195
Diabet Med. 2018 Jan;35(1):112-120
pubmed: 29111600
Diabetes Care. 2019 Apr;42(4):689-692
pubmed: 30877089

Auteurs

Valeria Calcaterra (V)

Pediatric and Adolescent Unit, Department of Internal Medicine, University of Pavia, 27100 Pavia, Italy.
Pediatric Unit, Department of Pediatrics, Children's Hospital "V. Buzzi", 20157 Milano, Italy.

Pietro Bosoni (P)

Department of Electrical, Computer and Biomedical Engineering, University of Pavia, 27100 Pavia, Italy.

Lucia Sacchi (L)

Department of Electrical, Computer and Biomedical Engineering, University of Pavia, 27100 Pavia, Italy.

Gian Vincenzo Zuccotti (GV)

Pediatric Unit, Department of Pediatrics, Children's Hospital "V. Buzzi", 20157 Milano, Italy.
Department of Biomedical and Clinical Sciences "L. Sacco", University of Milan, 20157 Milano, Italy.

Savina Mannarino (S)

Pediatric Cardiology Unit, Department of Pediatrics, Children's Hospital "V. Buzzi", 20157 Milano, Italy.

Riccardo Bellazzi (R)

Department of Electrical, Computer and Biomedical Engineering, University of Pavia, 27100 Pavia, Italy.

Cristiana Larizza (C)

Department of Electrical, Computer and Biomedical Engineering, University of Pavia, 27100 Pavia, Italy.

Classifications MeSH