Three-dimensional composition of the photoreceptor cone layers in healthy eyes using adaptive-optics optical coherence tomography (AO-OCT).


Journal

PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081

Informations de publication

Date de publication:
2021
Historique:
received: 15 09 2020
accepted: 25 12 2020
entrez: 7 1 2021
pubmed: 8 1 2021
medline: 14 5 2021
Statut: epublish

Résumé

To assess the signal composition of cone photoreceptors three-dimensionally in healthy retinas using adaptive optics optical coherence tomography (AO-OCT). Study population. Twenty healthy eyes of ten subjects (age 23 to 67). Procedures. After routine ophthalmological assessments, eyes were examined using AO-OCT. Three-dimensional volumes were acquired at 2.5° and 6.5° foveal eccentricity in four main meridians (superior, nasal, inferior, temporal). Cone densities and signal compositions were investigated in four different planes: the cone inner segment outer segment junction (IS/OS), the cone outer segment combined with the IS/OS (ISOS+), the cone outer segment tips (COST) and full en-face plane (FEF) combining signals from all mentioned cone layers. Additionally, reliability of a simple semi-automated approach for assessment of cone density was tested. Main outcome measures. Cone density of IS/OS, IS/OS+, COST and FEF. Qualitative depiction and composition of each cone layer. Inter-rater agreement of cone density measurements. Mean overall cone density at all eccentricities was highest at the FEF plane (21.160/mm2), followed by COST (20.450/mm2), IS/OS+ (19.920/mm2) and IS/OS (19.530/mm2). The different meridians and eccentricities had a significant impact on cone density, with lower eccentricity resulting in higher cone densities (p≤.001), which were highest at the nasal, then temporal, then inferior and then superior meridian. Depiction of the cone mosaic differed between all 4 layers regarding signal size and packing density. Therefore, different cone layers showed evident but not complete signal overlap. Using the semi-automated technique for counting of cone signals achieved high inter-rater reliability (ICC > .99). In healthy individuals qualitative and quantitative changes in cone signals are found not only in different eccentricities and meridians, but also within different photoreceptor layers. The variation between cone planes has to be considered when assessing the integrity of cone photoreceptors in healthy and diseased eyes using adaptive optics technology.

Identifiants

pubmed: 33412568
doi: 10.1371/journal.pone.0245293
pii: PONE-D-20-28955
pmc: PMC7790532
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e0245293

Déclaration de conflit d'intérêts

The authors have declared that no competing interests exist.

Références

Am J Ophthalmol. 2020 Jun;214:72-85
pubmed: 31883465
Retina. 2019 Mar;39(3):465-472
pubmed: 29360686
Invest Ophthalmol Vis Sci. 2016 Apr;57(4):1604-11
pubmed: 27050879
Biomed Opt Express. 2017 Apr 19;8(5):2536-2562
pubmed: 28663890
Int J Ophthalmol. 2017 Nov 18;10(11):1751-1758
pubmed: 29181321
Eye (Lond). 2011 Mar;25(3):321-30
pubmed: 21390066
Vision Res. 2017 Mar;132:34-44
pubmed: 27353225
Biomed Opt Express. 2011 Mar 01;2(4):748-63
pubmed: 21483600
Biomed Opt Express. 2016 Oct 13;7(11):4554-4568
pubmed: 27895995
Opt Express. 2005 Jun 13;13(12):4792-811
pubmed: 19495398
Opt Express. 2006 May 15;14(10):4380-94
pubmed: 19096730
Biomed Opt Express. 2016 Dec 12;8(1):207-222
pubmed: 28101412
Invest Ophthalmol Vis Sci. 2019 Mar 1;60(4):1144-1155
pubmed: 30901772
Invest Ophthalmol Vis Sci. 2014 Oct 16;55(12):7904-18
pubmed: 25324288
Br J Ophthalmol. 2018 Jan;102(1):146-152
pubmed: 29051326
Biomed Opt Express. 2016 Apr 11;7(5):1783-96
pubmed: 27231621
Invest Ophthalmol Vis Sci. 2011 Sep 21;52(10):7376-84
pubmed: 21724911
J Opt Soc Am A Opt Image Sci Vis. 1997 Nov;14(11):2884-92
pubmed: 9379246
Retina. 2019 Nov;39(11):2099-2106
pubmed: 30157112
Curr Eye Res. 2013 Jul;38(7):709-21
pubmed: 23621343
J Opt Soc Am A Opt Image Sci Vis. 2007 May;24(5):1373-83
pubmed: 17429483
Biomed Opt Express. 2014 Jan 10;5(2):439-56
pubmed: 24575339
Vision Res. 2011 Jul 1;51(13):1379-96
pubmed: 21596053
Am J Ophthalmol. 2015 Aug;160(2):290-300.e1
pubmed: 25935100
Opt Express. 2010 Jun 21;18(13):13935-44
pubmed: 20588526
Ocul Immunol Inflamm. 2017 Oct;25(5):610-620
pubmed: 28362542
Eye (Lond). 2016 Aug;30(8):1135-43
pubmed: 27229708
J Comp Neurol. 1990 Feb 22;292(4):497-523
pubmed: 2324310
Retina. 2012 Sep;32(8):1492-9
pubmed: 22481478
PLoS One. 2017 Jan 9;12(1):e0169926
pubmed: 28068435
Biomed Opt Express. 2010 Dec 15;2(1):100-12
pubmed: 21326640
PLoS One. 2016 Apr 08;11(4):e0152788
pubmed: 27057752
Biomed Opt Express. 2015 Aug 17;6(9):3378-404
pubmed: 26417509
Ophthalmology. 2010 Sep;117(9):1815-24
pubmed: 20472291
Biomed Opt Express. 2013 Nov 26;4(12):3007-29
pubmed: 24409397
Invest Ophthalmol Vis Sci. 2016 Jul 1;57(9):OCT51-68
pubmed: 27409507
Prog Retin Eye Res. 2019 Jan;68:1-30
pubmed: 30165239
Invest Ophthalmol Vis Sci. 2017 Sep 1;58(11):4559-4568
pubmed: 28877320
Invest Ophthalmol Vis Sci. 2016 Jul 1;57(8):3853-63
pubmed: 27447086
Exp Eye Res. 2013 Mar;108:1-9
pubmed: 23276813
Ophthalmic Physiol Opt. 2013 Jul;33(4):516-26
pubmed: 23550537
Opt Express. 2010 Mar 1;18(5):5257-70
pubmed: 20389538
Retina. 2018 Jan;38(1):137-147
pubmed: 28099315
Invest Ophthalmol Vis Sci. 1993 Nov;34(12):3278-96
pubmed: 8225863
Sensors (Basel). 2012 Dec 27;13(1):334-66
pubmed: 23271600
Retina. 2018 Jan;38(1):39-48
pubmed: 28166161

Auteurs

Adrian Reumueller (A)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Lorenz Wassermann (L)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Matthias Salas (M)

Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.

Markus Schranz (M)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Valentin Hacker (V)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Georgios Mylonas (G)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Stefan Sacu (S)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Wolfgang Drexler (W)

Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.

Michael Pircher (M)

Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.

Ursula Schmidt-Erfurth (U)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Andreas Pollreisz (A)

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH