Cementless ceramic-on-ceramic total hip arthroplasty in post-traumatic osteoarthritis after acetabular fracture: long-term results.
Acetabular fracture
Ceramic bearing
Long term
Modular neck
Total hip replacement
Journal
Archives of orthopaedic and trauma surgery
ISSN: 1434-3916
Titre abrégé: Arch Orthop Trauma Surg
Pays: Germany
ID NLM: 9011043
Informations de publication
Date de publication:
Apr 2021
Apr 2021
Historique:
received:
07
05
2020
accepted:
06
12
2020
pubmed:
9
1
2021
medline:
22
6
2021
entrez:
8
1
2021
Statut:
ppublish
Résumé
Total hip arthroplasty (THA) is the standard procedure for post-traumatic osteoarthritis (OA) of the hip after acetabular fracture. However, it is not as simple as a primary THA, challenging the surgeon with anatomical deformity and intra and postoperative complications. In the current literature, there is a lack of studies reporting long-term results. May ceramic-on-ceramic (CoC) bearings provide good clinical and radiological outcomes at a long-term follow-up in patients undergoing THA following acetabular fracture? We retrospectively analyzed 68 patients (mean age 47 years [range 22-75)] who underwent cementless modular neck stem THA, all implants CoC bearings (50 previously operatively treated and 18 non-operatively treated) after a specific CT study protocol at our Institute since 2000-2008. Clinical outcomes, prosthetic components' osseointegration, survival rate, and reasons for revision were analyzed. Minimum clinical and radiological follow-up was 10 years. HHS improved significantly after surgery from 37.6 ± 14.1 to 88.4 ± 11.6. 8 revision surgeries were performed, none for infection: we reported 2 stem aseptic loosening, 2 periprosthetic femoral fractures and 4 modular neck fractures. One implant noise (third-generation ceramic coupling) was described. Cup osseointegration was present (according to Moore the presence of at least 3 radiological criteria defines an effective osseointegration) in 67 patients (98.5%). After a 10 years follow-up, survival rate resulted 88.4%, sensibly higher than most of results reported in the current literature. The high survival rate may be related to CoC: no osteolysis and no infections were reported. Also acetabular cup loosening incidence was sensibly lower (1.47%) among loosening rate described by other authors. Clinical and radiological outcomes were decent, probably due to modular prosthesis design. Modular necks are a solution which can help achieving a proper functional reconstruction of the hip (offset, center of rotation), but should be avoided in young and overweight patients because of the high risk of fracture. CoC bearings in THAs in post-traumatic OA after acetabular fracture showed good results despite the fact that specific ceramic-related issues have to be considered.
Identifiants
pubmed: 33417021
doi: 10.1007/s00402-020-03711-0
pii: 10.1007/s00402-020-03711-0
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
683-691Références
Bellabarba C, Berger RA, Bentley CD et al (2001) Cementless acetabular reconstruction after acetabular fracture. J Bone Joint Surg Am 83(6):868–876. https://doi.org/10.2106/00004623-200106000-00008
doi: 10.2106/00004623-200106000-00008
pubmed: 11407795
Mauffrey C, Hao J, Cuellar DO 3rd et al (2014) The epidemiology and injury patterns of acetabular fractures: are the USA and China comparable? ClinOrthopRelat Res 472:3332–3337. https://doi.org/10.1007/s11999-014-3462-8
doi: 10.1007/s11999-014-3462-8
Makridis KG, Obakponovwe O, Bobak P, Giannoudis PV (2014) Total hip arthroplasty after acetabular fracture: incidence of complications, reoperation rates and functional outcomes: evidence today. J Arthroplasty 29:1983–1990. https://doi.org/10.1016/j.arth.2014.06.001
doi: 10.1016/j.arth.2014.06.001
pubmed: 25034883
Matta JM, Ferguson TA (2005) Total hip replacement after acetabular fracture. Orthopedics 28:959–960
doi: 10.3928/0147-7447-20050901-23
Tannast M, Najibi S, Matta JM (2012) Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures. J Bone Joint Surg Am 94:1559–1567. https://doi.org/10.2106/JBJS.K.00444
doi: 10.2106/JBJS.K.00444
pubmed: 22992846
Weber M, Berry DJ, Harmsen WS (1998) Total hip arthroplasty after operative treatment of an acetabular fracture. J Bone Joint Surg Am 80:1295–1305
doi: 10.2106/00004623-199809000-00008
Busse J, Gasteiger W, Tönnis D (1972) A new method for roentgenologic evaluation of the hip joint–the hip factor. Arch OrthopUnfallchir 72:1–9. https://doi.org/10.1007/BF00415854
doi: 10.1007/BF00415854
Letournel E (1980) Acetabulum fractures: classification and management. Clin Orthop Relat Res. https://doi.org/10.1097/00003086-198009000-00012
doi: 10.1097/00003086-198009000-00012
pubmed: 7418327
Toni A, Traina F, De Fine M et al (2008) Anterolateral soft tissue sparing approach to the hip. Surgical technique. La Chirurgiadegliorgani di movimento 92:23–27. https://doi.org/10.1007/s12306-008-0040-9
doi: 10.1007/s12306-008-0040-9
Toni A, Traina F, Viceconti M (2003) Computer-assisted tridimensional preoperative planning in hip revision surgery. ChirOrganiMov 88:273–280
Traina F, De Fine M, Biondi F et al (2009) The influence of the centre of rotation on implant survival using a modular stem hip prosthesis. IntOrthop 33:1513–1518. https://doi.org/10.1007/s00264-008-0710-0
doi: 10.1007/s00264-008-0710-0
Ollivier M, Parratte S, Galland A et al (2015) Are titanium-on-titanium TiAl6V4 modular necks safe in total hip arthroplasty for non-overweight patients? Results of a prospective series at a minimum follow-up of 7 years. Eur J OrthopSurgTraumatol: OrthopTraumatol 25:1147–1152. https://doi.org/10.1007/s00590-015-1665-7
doi: 10.1007/s00590-015-1665-7
Montalti M, Castagnini F, Giardina F et al (2018) Cementless total hip arthroplasty in Crowe III and IV dysplasia: high hip center and modular necks. J Arthroplast 33:1813–1819. https://doi.org/10.1016/j.arth.2018.01.041
doi: 10.1016/j.arth.2018.01.041
Moore MS, McAuley JP, Young AM, Engh CA Sr (2006) Radiographic signs of osseointegration in porous-coated acetabular components. ClinOrthopRelat Res 444:176–183. https://doi.org/10.1097/01.blo.0000201149.14078.50
doi: 10.1097/01.blo.0000201149.14078.50
Lewinnek GE, Lewis JL, Tarr R et al (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220
doi: 10.2106/00004623-197860020-00014
Manjunath KS, Soruban V, Gopalakrishna KG (2015) Evaluation of radiological methods of assessing cup anteversion in total hip replacement. Eur J OrthopSurgTraumatol: OrthopTraumatol 25:1285–1292. https://doi.org/10.1007/s00590-015-1702-6
doi: 10.1007/s00590-015-1702-6
Lecerf G, Fessy MH, Philippot R et al (2009) Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. OrthopTraumatol, Surg Res 95:210–219. https://doi.org/10.1016/j.otsr.2009.03.010
doi: 10.1016/j.otsr.2009.03.010
Min B-W, Song K-S, Bae K-C et al (2008) The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplast 23:418–423. https://doi.org/10.1016/j.arth.2007.04.002
doi: 10.1016/j.arth.2007.04.002
Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. https://doi.org/10.1097/00003086-199008000-00022
doi: 10.1097/00003086-199008000-00022
pubmed: 2245564
DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. https://doi.org/10.1097/00003086-197906000-00002
doi: 10.1097/00003086-197906000-00002
pubmed: 991504
Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. https://doi.org/10.1097/00003086-197906000-00002
doi: 10.1097/00003086-197906000-00002
pubmed: 477100
Zhang Q, Goodman SB, Maloney WJ, Huddleston JI 3rd (2016) Can a conical implant successfully address complex anatomy in primary THA? Radiographs and hip scores at early followup. ClinOrthopRelat Res 474:459–464. https://doi.org/10.1007/s11999-015-4480-x
doi: 10.1007/s11999-015-4480-x
Toni A, Traina F, Stea S et al (2006) Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. https://doi.org/10.2106/JBJS.F.00587
doi: 10.2106/JBJS.F.00587
pubmed: 17142435
Callaghan JJ, Salvati EA, Pellicci PM et al (1985) Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am 67:1074–1085
doi: 10.2106/00004623-198567070-00011
Attenello J, Chan S, Naito K et al (2019) Early perioperative complication rates and subsidence with the Tribute
doi: 10.1016/j.jor.2019.01.002
pubmed: 30723362
pmcid: 6354216
Morison Z, Moojen DJ, Nauth A et al (2016) Total hip arthroplasty after acetabular fracture is associated with lower survivorship and more complications. ClinOrthopRelat Res 474:392–398. https://doi.org/10.1007/s11999-015-4509-1
doi: 10.1007/s11999-015-4509-1
Ranawat A, Zelken J, Helfet D, Buly R (2009) Total hip arthroplasty for posttraumatic arthritis after acetabular fracture. J Arthroplast 24:759–767. https://doi.org/10.1016/j.arth.2008.04.004
doi: 10.1016/j.arth.2008.04.004
Yuan BJ, Lewallen DG, Hanssen AD (2015) Porous metal acetabular components have a low rate of mechanical failure in THA after operatively treated acetabular fracture. ClinOrthopRelat Res 473:536–542. https://doi.org/10.1007/s11999-014-3852-y
doi: 10.1007/s11999-014-3852-y
Madanat R, Laaksonen I, Graves SE et al (2018) Ceramic bearings for total hip arthroplasty are associated with a reduced risk of revision for infection. Hip Int 28:222–226. https://doi.org/10.1177/1120700018776464
doi: 10.1177/1120700018776464
pubmed: 30165763
Traina F, Bordini B, De Fine M, Toni A (2011) Patient weight more than body mass index influences total hip arthroplasty long term survival. HIP International 21:694–699. https://doi.org/10.5301/HIP.2011.8879
doi: 10.5301/HIP.2011.8879
pubmed: 22144336
Skendzel JG, Blaha JD, Urquhart AG (2011) Total hip arthroplasty modular neck failure. J Arthroplast 26(338):e1-4. https://doi.org/10.1016/j.arth.2010.03.011
doi: 10.1016/j.arth.2010.03.011
Graves SE, de Steiger R, Davidson D et al (2017) The use of femoral stems with exchangeable necks in primary total hip arthroplasty increases the rate of revision. Bone Joint J 99-B(6):766–773. https://doi.org/10.1302/0301-620X.99B6.38020
doi: 10.1302/0301-620X.99B6.38020
pubmed: 28566395
von Roth P, Abdel MP, Harmsen WS, Berry DJ (2015) Total hip arthroplasty after operatively treated acetabular fracture: a concise follow-up, at a mean of twenty years, of a previous report. J Bone Joint Surg Am 97:288–291. https://doi.org/10.2106/JBJS.N.00871
doi: 10.2106/JBJS.N.00871
Massin P, Lopes R, Masson B et al (2014) Does Biolox Delta ceramic reduce the rate of component fractures in total hip replacement? OrthopTraumatol, Surg Res 100:S317–S321. https://doi.org/10.1016/j.otsr.2014.05.010
doi: 10.1016/j.otsr.2014.05.010
Hamilton WG, McAuley JP, Blumenfeld TJ et al (2015) Midterm results of delta ceramic-on-ceramic total hip arthroplasty. J Arthroplast 30:110–115. https://doi.org/10.1016/j.arth.2015.02.047
doi: 10.1016/j.arth.2015.02.047