An experimental validation of partial discharge localization using electromagnetic time reversal.
Journal
Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288
Informations de publication
Date de publication:
08 Jan 2021
08 Jan 2021
Historique:
received:
30
04
2020
accepted:
18
12
2020
entrez:
9
1
2021
pubmed:
10
1
2021
medline:
10
1
2021
Statut:
epublish
Résumé
The localization of partial discharge (PD) sources is of importance for the monitoring and maintenance of power transformers. Time difference of arrival (TDoA) based methods are widely adopted in the literature for the localization of PDs. Recently, time reversal (TR) was suggested as an efficient means to locate PD sources. As opposed to TDoA, which needs at least 4 sensors, TR is able to locate PD sources in power transformers with only one sensor. Moreover, it needs neither line-of-sight wave propagation from the PD sources to the sensor nor time synchronization. In this study, we present for the first time an experimental demonstration of the ability of the TR process to locate PD sources. A typical TR process includes three steps: (1) recording the PD-emitted field by a sensor, (2) time reversing and back injecting the signal into the medium, (3) using a proper criterion to obtain the focusing point which corresponds to the location of the PD source. In this work, we present a laboratory setup in which steps one and two are performed experimentally, both in the frequency and in the time domain. The obtained peak electric field value is used as a criterion in the third step. It is found that the accuracy of the proposed method is better than 2.5 cm in a transformer tank model with dimensions 73 × 73 × 103 cm
Identifiants
pubmed: 33420279
doi: 10.1038/s41598-020-80660-z
pii: 10.1038/s41598-020-80660-z
pmc: PMC7794480
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
220Références
Phys Rev Lett. 2004 Dec 10;93(24):243904
pubmed: 15697814
Phys Rev Lett. 2004 May 14;92(19):193904
pubmed: 15169405
Sci Rep. 2018 Nov 30;8(1):17486
pubmed: 30504787
Sci Rep. 2018 Feb 8;8(1):2685
pubmed: 29422535
IEEE Trans Ultrason Ferroelectr Freq Control. 1992;39(5):567-78
pubmed: 18267668
Sci Rep. 2019 Nov 22;9(1):17372
pubmed: 31758075
Sensors (Basel). 2020 Mar 05;20(5):
pubmed: 32150914
Nat Rev Neurol. 2012 Sep;8(9):498-507
pubmed: 22868868
Sci Rep. 2017 Aug 7;7(1):7472
pubmed: 28785020
Phys Rev Lett. 2003 Jan 10;90(1):014301
pubmed: 12570617
Science. 2007 Feb 23;315(5815):1120-2
pubmed: 17322059
Opt Lett. 2007 Nov 1;32(21):3107-9
pubmed: 17975612
J Acoust Soc Am. 2003 Mar;113(3):1533-43
pubmed: 12656388