High-Resolution Cone-Beam Computed Tomography is a Fast and Promising Technique to Quantify Bone Microstructure and Mechanics of the Distal Radius.


Journal

Calcified tissue international
ISSN: 1432-0827
Titre abrégé: Calcif Tissue Int
Pays: United States
ID NLM: 7905481

Informations de publication

Date de publication:
03 2021
Historique:
received: 05 05 2020
accepted: 27 10 2020
pubmed: 17 1 2021
medline: 30 7 2021
entrez: 16 1 2021
Statut: ppublish

Résumé

Obtaining high-resolution scans of bones and joints for clinical applications is challenging. HR-pQCT is considered the best technology to acquire high-resolution images of the peripheral skeleton in vivo, but a breakthrough for widespread clinical applications is still lacking. Recently, we showed on trapezia that CBCT is a promising alternative providing a larger FOV at a shorter scanning time. The goals of this study were to evaluate the accuracy of CBCT in quantifying trabecular bone microstructural and predicted mechanical parameters of the distal radius, the most often investigated skeletal site with HR-pQCT, and to compare it with HR-pQCT. Nineteen radii were scanned with four scanners: (1) HR-pQCT (XtremeCT, Scanco Medical AG, @ (voxel size) 82 μm), (2) HR-pQCT (XtremeCT-II, Scanco, @60.7 μm), (3) CBCT (NewTom 5G, Cefla, @75 μm) reconstructed and segmented using in-house developed software and (4) microCT (VivaCT40, Scanco, @19 μm-gold standard). The following parameters were evaluated: predicted stiffness, strength, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The overall accuracy of CBCT with in-house optimized algorithms in quantifying bone microstructural parameters was comparable (R

Identifiants

pubmed: 33452889
doi: 10.1007/s00223-020-00773-5
pii: 10.1007/s00223-020-00773-5
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

314-323

Références

Peacock M, Turner CH, Econs MJ, Foroud T (2002) Genetics of osteoporosis. Endocr Rev 23:303–326. https://doi.org/10.1007/s10354-005-0249-2
doi: 10.1007/s10354-005-0249-2 pubmed: 12050122
Hernlund E, Svedbom A, Ivergård M et al (2013) Osteoporosis in the European Union: medical management, epidemiology and economic burden: a report prepared in collaboration with the International Osteoporosis Foundation (IOF) and the European Federation of Pharmaceutical Industry Associations (EFPIA). Arch Osteoporos. https://doi.org/10.1007/s11657-013-0136-1
doi: 10.1007/s11657-013-0136-1 pubmed: 24113838 pmcid: 3880492
Blake GM, Fogelman I (2007) The role of DXA bone density scans in the diagnosis and treatment of osteoporosis. Postgrad Med J 83:509–517. https://doi.org/10.1136/pgmj.2007.057505
doi: 10.1136/pgmj.2007.057505 pubmed: 17675543 pmcid: 2600106
Kanis JA, Johnell O, Oden A et al (2008) FRAX
doi: 10.1007/s00198-007-0543-5 pubmed: 18292978 pmcid: 2267485
Sanders KM, Nicholson GC, Watts JJ et al (2006) Half the burden of fragility fractures in the community occur in women without osteoporosis. When is fracture prevention cost-effective? Bone 38:694–700. https://doi.org/10.1016/j.bone.2005.06.004
doi: 10.1016/j.bone.2005.06.004 pubmed: 16507356
Schuit SCE, Van Der Klift M, Weel AEAM et al (2004) Fracture incidence and association with bone mineral density in elderly men and women: the Rotterdam Study. Bone 34:195–202. https://doi.org/10.1016/j.bone.2003.10.001
doi: 10.1016/j.bone.2003.10.001 pubmed: 14751578
Müller R, Hildebrand T, Rüegsegger P (1994) Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone. Phys Med Biol 39:145–164. https://doi.org/10.1088/0031-9155/39/1/009
doi: 10.1088/0031-9155/39/1/009 pubmed: 7651993
De Cock J, Mermuys K, Goubau J et al (2012) Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique. Skeletal Radiol 41:93–96. https://doi.org/10.1007/s00256-011-1198-z
doi: 10.1007/s00256-011-1198-z pubmed: 21603872
Mys K, Stockmans F, Vereecke E, van Lenthe GH (2018) Quantification of bone microstructure in the wrist using cone-beam computed tomography. Bone 114:206–214. https://doi.org/10.1016/j.bone.2018.06.006
doi: 10.1016/j.bone.2018.06.006 pubmed: 29909060
Mys K, Varga P, Gueorguiev B et al (2018) A comparative analysis between cone-beam computed tomography and high-resolution peripheral computed tomography for the quantification of bone microstructure in the wrist. J Bone Miner Res 34(5):867–874
doi: 10.1002/jbmr.3673
Elizabeth JS, Biver E, Burt L et al (2019) Cortical and trabecular bone microarchitecture predicts incident fracture independently of DXA bone minderal density and FRAX in older women and men: the Bone Microarchitecture International Consortium (BoMIC). Lancet 7:34–43. https://doi.org/10.1016/S2213-8587(18)30308-5.Cortical
doi: 10.1016/S2213-8587(18)30308-5.Cortical
Mys K, Varga P, Gueorguiev B et al (2019) Correlation between cone-beam computed tomography and high-resolution peripheral computed tomography for assessment of wrist bone microstructure. J Bone Miner Res 34:867–874. https://doi.org/10.1002/jbmr.3673
doi: 10.1002/jbmr.3673 pubmed: 30912861
MacNeil JA, Boyd SK (2007) Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys 29:1096–1105. https://doi.org/10.1016/j.medengphy.2006.11.002
doi: 10.1016/j.medengphy.2006.11.002 pubmed: 17229586
Buie HR, Campbell GM, Klinck RJ et al (2007) Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone 41:505–515. https://doi.org/10.1016/j.bone.2007.07.007
doi: 10.1016/j.bone.2007.07.007 pubmed: 17693147
Flaig C (2012) A highly scalable memory efficient multigrid solver for micro-finite element analyses. ETH Zurich
Pistoia W, van Rietbergen B, Lochmüller E-M et al (2002) Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. Bone 30:842–848
doi: 10.1016/S8756-3282(02)00736-6
Kothari M, Keaveny TM, Lin JC et al (1998) Impact of spatial resolution on the prediction of trabecular architecture parameters. Bone 22:437–443. https://doi.org/10.1016/S8756-3282(98)00031-3
doi: 10.1016/S8756-3282(98)00031-3 pubmed: 9600776
de Charry C, Boutroy S, Ellouz R et al (2016) Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone. Osteoporos Int 27:3073–3082. https://doi.org/10.1007/s00198-016-3609-4
doi: 10.1007/s00198-016-3609-4 pubmed: 27121345
Klintström E, Klintström B, Moreno R et al (2016) Predicting trabecular bone stiffness from clinical cone-beam CT and HR-pQCT data; an in vitro study using finite element analysis. PLoS ONE 11:1–19. https://doi.org/10.1371/journal.pone.0161101
doi: 10.1371/journal.pone.0161101
Klintström E, Klintström B, Pahr D et al (2018) Direct estimation of trabecular bone stiffness using cone-beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 126:72–82. https://doi.org/10.1016/j.oooo.2018.03.014
doi: 10.1016/j.oooo.2018.03.014 pubmed: 29735401
Verhulp E, Van RB, Müller R, Huiskes R (2008) Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations. J Biomech 41:1479–1485. https://doi.org/10.1016/j.jbiomech.2008.02.032
doi: 10.1016/j.jbiomech.2008.02.032 pubmed: 18423473
Macneil JA, Boyd SK (2008) Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method. Bone 42:1203–1213. https://doi.org/10.1016/j.bone.2008.01.017
doi: 10.1016/j.bone.2008.01.017 pubmed: 18358799
Graeff C, Marin F, Petto H et al (2013) High resolution quantitative computed tomography-based assessment of trabecular microstructure and strength estimates by finite-element analysis of the spine, but not DXA, reflects vertebral fracture status in men with glucocorticoid-induced osteoporosis. Bone 52:568–577. https://doi.org/10.1016/j.bone.2012.10.036
doi: 10.1016/j.bone.2012.10.036 pubmed: 23149277

Auteurs

Karen Mys (K)

Biomechanics Section, Mechanical Engineering, KU Leuven, Leuven, Belgium. Karen.Mys@aofoundation.org.
AO Research Institute Davos, Davos, Switzerland. Karen.Mys@aofoundation.org.

Peter Varga (P)

AO Research Institute Davos, Davos, Switzerland.

Filip Stockmans (F)

Muscles & Movement, Department of Development and Regeneration, KU Leuven Campus Kulak, Kortrijk, Belgium.

Boyko Gueorguiev (B)

AO Research Institute Davos, Davos, Switzerland.

Verena Neumann (V)

AO Research Institute Davos, Davos, Switzerland.

Olivier Vanovermeire (O)

Department of Radiology, AZ Groeninge, Kortrijk, Belgium.

Caroline E Wyers (CE)

Department of Internal Medicine, VieCuri Medical Center, Venlo, The Netherlands.
NUTRIM School for Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands.

Joop P W van den Bergh (JPW)

Department of Internal Medicine, VieCuri Medical Center, Venlo, The Netherlands.
NUTRIM School for Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands.
Rheumatology, Department of Internal Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.

G Harry van Lenthe (GH)

Biomechanics Section, Mechanical Engineering, KU Leuven, Leuven, Belgium.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH