Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass.


Journal

Medicine
ISSN: 1536-5964
Titre abrégé: Medicine (Baltimore)
Pays: United States
ID NLM: 2985248R

Informations de publication

Date de publication:
15 Jan 2021
Historique:
received: 06 07 2020
accepted: 11 12 2020
entrez: 20 1 2021
pubmed: 21 1 2021
medline: 27 1 2021
Statut: ppublish

Résumé

There is a growing need for tissue collection for immunostaining and genetic testing. Recently, several fine-needle biopsy needles are commercially available for endoscopic ultrasound-guided tissue acquisition.This prospective historical controlled study evaluates a 20G core biopsy needle with a forward bevel for solid pancreatic masses larger than 15 mm in diameter. The primary endpoint was the accuracy of histological diagnosis. The secondary endpoints included technical success rate, sample adequacy for histology, cytological diagnostic accuracy, and adverse events.Seventy consecutive patients were enrolled between January and October 2017. We achieved technical success in all cases regardless of the puncture sites or the endosonographer's experience. The final diagnoses were neoplasms in 67 patients (95.7%; pancreatic cancer in 65 patients, neuroendocrine neoplasm in 1, and malignant lymphoma in 1) and benign lesions in 3 patients (4.3%; autoimmune pancreatitis in 2 patients and mass-forming pancreatitis in 1). The obtained specimens were adequate for histological evaluation in all cases and the histological accuracy was 91.4% (95% confidence interval, 82.3-96.8%, P < .05) with the sensitivity and specificity of 91.0% and 100%, respectively. The cytological diagnostic accuracy was 95.7% and all patients were accurately diagnosed by combining cytological and histological examinations. As for adverse events, an asymptomatic needle fracture occurred in 1 case (1.4%).This 20G core biopsy needle with a forward bevel showed a high accuracy of histological diagnosis for solid pancreatic masses.

Identifiants

pubmed: 33466194
doi: 10.1097/MD.0000000000024193
pii: 00005792-202101150-00077
pmc: PMC7808531
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e24193

Informations de copyright

Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.

Déclaration de conflit d'intérêts

TS has received honoraria from Boston Scientific Japan, Cook Medical Japan and Century Medical Inc. NS has received honoraria from Boston Scientific Japan and Cook Medical Japan. Remaining authors authors have no conflicts of interest to disclose.

Références

Vilmann P, Hancke S, Henriksen FW, et al. Endosonographically-guided fine needle aspiration biopsy of malignant lesions in the upper gastrointestinal tract. Endoscopy 1993;25:523–7.
Dumonceau JM, Deprez PH, Jenssen C, et al. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline – Updated January 2017. Endoscopy 2017;49:695–714.
Voss M, Hammel P, Molas G, et al. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses. Gut 2000;46:244–9.
Fritscher-Ravens A, Izbicki JR, Sriram PV, et al. Endosonography-guided, fine-needle aspiration cytology extending the indication for organ-preserving pancreatic surgery. Am J Gastroenterol 2000;95:2255–60.
Harewood GC, Wiersema MJ. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses. Am J Gastroenterol 2002;97:1386–91.
Ryozawa S, Kitoh H, Gondo T, et al. Usefulness of endoscopic ultrasound-guided fine-needle aspiration biopsy for the diagnosis of pancreatic cancer. J Gastroenterol 2005;40:907–11.
Iwashita T, Yasuda I, Doi S, et al. Use of samples from endoscopic ultrasound-guided 19-gauge fine-needle aspiration in diagnosis of autoimmune pancreatitis. Clin Gastroenterol Hepatol 2012;10:316–22.
Kanno A, Ishida K, Hamada S, et al. Diagnosis of autoimmune pancreatitis by EUS-FNA by using a 22-gauge needle based on the International Consensus Diagnostic Criteria. Gastrointest Endosc 2012;76:594–602.
Bhatia V, Varadarajulu S. Endoscopic ultrasonography-guided tissue acquisition: how to achieve excellence. Dig Endosc 2017;29:417–30.
Lee YN, Moon JH, Kim HK, et al. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy 2014;46:1056–62.
Lee BS, Cho CM, Jung MK, et al. Comparison of histologic core portions acquired from a core biopsy needle and a conventional needle in solid mass lesions: a prospective randomized trial. Gut Liver 2017;11:559–66.
Sterlacci W, Sioulas AD, Veits L, et al. 22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses. World J Gastroenterol 2016;22:8820–30.
Cotton PB, Eisen GM, Aabakken L, et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010;71:446–54.
Sasaki T, Kanata R, Sasahira N. Needle fracture during endoscopic ultrasound-guided fine needle aspiration using a needle with a side hole. Endosc Int Open 2018;6:E553–7.
Armellini E, Manfrin E, Trisolini E, et al. Histologic retrieval rate of a newly designed side-bevelled 20G needle for EUS-guided tissue acquisition of solid pancreatic lesions. United Eur Gastroenterol J 2019;7:96–104.
van Riet PA, Larghi A, Attili F, et al. A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS-fine-needle biopsy device. Gastrointest Endosc 2019;89:329–39.
Karsenti D, Tharsis G, Zeitoun JD, et al. Comparison of 20-gauge Procore ® and 22-gauge Acquire ® needles for EUS-FNB of solid pancreatic masses: an observational study. Scand J Gastroenterol 2019;54:499–505.
Iglesias-Garcia J, Poley JW, Larghi A, et al. Feasibility and yield of a new EUS histology needle: Results from a multicenter, pooled, cohort study. Gastrointest Endosc 2011;73:1189–96.
Song TJ, Kim JH, Lee SS, et al. The prospective randomized, controlled trial of endoscopic ultrasound-guided fine-needle aspiration using 22G and 19G aspiration needles for solid pancreatic or peripancreatic masses. Am J Gastroenterol 2010;105:1739–45.
Itoi T, Itokawa F, Sofuni A, et al. Evaluation of 19-gauge endoscopic ultrasonography aspiration needles using various echoendoscopes. Endosc Int Open 2013;1:24–30.
Lee JK, Lee KT, Choi ER, et al. A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses. Scand J Gastroenterol 2013;48:752–7.
Sakamoto H, Kitano M, Komaki T, et al. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses. J Gastroenterol Hepatol 2009;24:384–90.
Adler DG, Witt B, Chadwick B, et al. Pathologic evaluation of a new endoscopic ultrasound needle designed to obtain core tissue samples: a pilot study. Endosc Ultrasound 2016;5:178–83.
Kandel P, Tranesh G, Nassar A, et al. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study. Gastrointest Endosc 2016;84:1034–9.
Bang JY, Hebert-Magee S, Hasan MK, et al. Endoscopic ultrasonography-guided biopsy using a Franseen needle design: initial assessment. Dig Endosc 2017;29:338–46.
Adler DG, Muthusamy VR, Ehrlich DS, et al. A multicenter evaluation of a new EUS core biopsy needle: experience in 200 patients. Endosc Ultrasound 2019;8:99–104.

Auteurs

Ryo Kanata (R)

Department of Hepato-Biliary-Pancreatic Medicine.

Takashi Sasaki (T)

Department of Hepato-Biliary-Pancreatic Medicine.

Masato Matsuyama (M)

Department of Hepato-Biliary-Pancreatic Medicine.

Kazunaga Ishigaki (K)

Department of Hepato-Biliary-Pancreatic Medicine.

Ikuhiro Yamada (I)

Department of Hepato-Biliary-Pancreatic Medicine.

Masato Ozaka (M)

Department of Hepato-Biliary-Pancreatic Medicine.

Koichi Takano (K)

Department of Hepato-Biliary-Pancreatic Medicine.

Yutaka Takazawa (Y)

Department of Clinicopathology Center.

Naoki Ishizuka (N)

Department of Clinical Trial Planning and Management, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.

Naoki Sasahira (N)

Department of Hepato-Biliary-Pancreatic Medicine.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH