Development and first biomechanical validation of a score to predict bone implant interface stability based on clinical qCT scans.
Journal
Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288
Informations de publication
Date de publication:
08 02 2021
08 02 2021
Historique:
received:
14
09
2020
accepted:
22
01
2021
entrez:
9
2
2021
pubmed:
10
2
2021
medline:
16
11
2021
Statut:
epublish
Résumé
Sufficient implant anchoring in osteoporotic bone is one major challenge in trauma and orthopedic surgery. In these cases, preoperative planning of osteosynthesis is becoming increasingly important. This study presents the development and first biomechanical validation of a bone-implant-anchorage score based on clinical routine quantitative computer tomography (qCT) scans. 10 pairs of fresh frozen femora (mean age 77.4 years) underwent clinical qCT scans after placing 3 referential screws (for matching with the second scan). Afterwards, three 4.5 mm cortical screws (DePuy Synthes, Zuchwil, Switzerland) were placed in each distal femur in the dia-metaphyseal transition followed by the second CT scan. The femur was segmented using thresholding and its outer shape was visualized as a surface model. A 3D model of the cortex screw in STL format was used to model the screw surface precisely. For each femur, the 3 cortex screw models were exactly positioned at the locations previously determined using the second CT scan. The BMD value was calculated at the center of each triangle as an interpolation from the measured values at the three vertices (triangle corners) in the CT. Scores are based on the sum of all the triangles' areas multiplied by their BMD values. Four different scores were calculated. A screw pull-out test was performed until loss of resistance. A quadratic model adequately describes the relation between all the scores and pull-out values. The square of the best score explains just fewer than 70% of the total variance of the pull-out values and the standardized residual which were approximately normally distributed. In addition, there was a significant correlation between this score and the peak pull-out force (p < 0.001). The coefficient of determination was 0.82. The presented score has the potential to improve preoperative planning by adding the mechanical to the anatomical dimension when planning screw placement.
Identifiants
pubmed: 33558603
doi: 10.1038/s41598-021-82788-y
pii: 10.1038/s41598-021-82788-y
pmc: PMC7870929
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Validation Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
3273Références
Injury. 2013 Oct;44(10):1327-32
pubmed: 23769470
Injury. 2014 Jun;45(6):988-94
pubmed: 24507831
Unfallchirurg. 2019 Oct;122(10):755-761
pubmed: 31428807
World J Orthop. 2020 Jan 18;11(1):57-67
pubmed: 31966970
BMC Musculoskelet Disord. 2018 Oct 15;19(1):374
pubmed: 30322393
J Orthop Surg Res. 2019 Apr 29;14(1):115
pubmed: 31036029
Unfallchirurg. 2015 Sep;118(9):765-71
pubmed: 26271219
Acta Biomed. 2014 Aug 20;85(2):144-51
pubmed: 25245650
J Orthop Res. 2017 Jul;35(7):1485-1493
pubmed: 27564231
Clin Biomech (Bristol, Avon). 2012 Jan;27(1):71-6
pubmed: 21824697
Spine J. 2020 Apr;20(4):621-628
pubmed: 31669611
J Trauma Acute Care Surg. 2012 Feb;72(2):E54-9
pubmed: 22439233
J Orthop Res. 2015 Jul;33(7):988-92
pubmed: 25676391
Arch Osteoporos. 2011;6:59-155
pubmed: 22886101
Injury. 2016 Jun;47 Suppl 2:S27-32
pubmed: 27338223
Injury. 2018 Aug;49(8):1436-1444
pubmed: 29724590
Injury. 2016 Jun;47 Suppl 2:S3-S10
pubmed: 27338224
Injury. 2013 Jun;44(6):808-12
pubmed: 23000049
Clin Biomech (Bristol, Avon). 2010 Jul;25(6):576-81
pubmed: 20385434
Medicine (Baltimore). 2014 Nov;93(23):e166
pubmed: 25415673
J Bone Joint Surg Am. 2018 Jun 6;100(11):936-941
pubmed: 29870444