Intraoperative Computed Tomography-Assisted Spinal Navigation in Dorsal Cervical Instrumentation: A Prospective Study on Accuracy Regarding Different Pathologies and Screw Types.

Accuracy Cervical pedicle screws Cervical spine Intraoperative computed tomography Lateral mass screws Navigated instrumentation

Journal

World neurosurgery
ISSN: 1878-8769
Titre abrégé: World Neurosurg
Pays: United States
ID NLM: 101528275

Informations de publication

Date de publication:
05 2021
Historique:
received: 03 12 2020
revised: 01 02 2021
accepted: 02 02 2021
pubmed: 13 2 2021
medline: 6 8 2021
entrez: 12 2 2021
Statut: ppublish

Résumé

Intraoperative computed tomography (iCT) navigated dorsal instrumentation has been successfully introduced as a new clinical standard. The proximity of vital anatomic structures makes cervical spine instrumentation an especially delicate task. Therefore, navigated approaches might prove to be beneficial. In this study, the accuracy of conventional instrumentation was compared with iCT navigated dorsal cervical spine instrumentation with focus on cervical pedicle screws (CPSs) versus lateral mass screws (LMSs) and pathologies. We analyzed a prospective consecutive series of patients undergoing cervical dorsal instrumentation with iCT and spinal navigation and retrospectively analyzed a cohort that received conventional cervical instrumentation with C-arm fluoroscopy (control group). Accuracy was assessed with a modified Gertzbein-Robbins classification. Underlying pathologies were taken into account regarding accuracy in different entities. Fifty-nine patients were treated using iCT (357 screws: 238 CPSs, 119 LMSs), and 98 patients underwent conventional instrumentation (632 screws: 69 CPSs, 563 LMSs). We achieved an initial accuracy of 93.28% (n = 220 screws) in the iCT group and 80.9% (n = 511 screws) in the control group (P < 0.001). Significant differences were found regarding the accuracy of CPS placement in cases of degenerative disorders (iCT vs. control; 94% vs. 63%; P < 0.001) and trauma (iCT vs. control; 88% vs. 72%; P < 0.05). iCT yielded favorable precision rates in regard to LMS placement (iCT vs. control; 94.2% vs. 82%; P < 0.05). Accuracy of iCT navigated instrumentation was significantly higher than conventional instrumentation. An overall tendency toward the use of CPSs with iCT navigation is evident, increasing the mechanical properties of the construct. iCT appears to be especially beneficial in elective surgery cases of degenerative spinal disorders.

Sections du résumé

BACKGROUND
Intraoperative computed tomography (iCT) navigated dorsal instrumentation has been successfully introduced as a new clinical standard. The proximity of vital anatomic structures makes cervical spine instrumentation an especially delicate task. Therefore, navigated approaches might prove to be beneficial. In this study, the accuracy of conventional instrumentation was compared with iCT navigated dorsal cervical spine instrumentation with focus on cervical pedicle screws (CPSs) versus lateral mass screws (LMSs) and pathologies.
METHODS
We analyzed a prospective consecutive series of patients undergoing cervical dorsal instrumentation with iCT and spinal navigation and retrospectively analyzed a cohort that received conventional cervical instrumentation with C-arm fluoroscopy (control group). Accuracy was assessed with a modified Gertzbein-Robbins classification. Underlying pathologies were taken into account regarding accuracy in different entities.
RESULTS
Fifty-nine patients were treated using iCT (357 screws: 238 CPSs, 119 LMSs), and 98 patients underwent conventional instrumentation (632 screws: 69 CPSs, 563 LMSs). We achieved an initial accuracy of 93.28% (n = 220 screws) in the iCT group and 80.9% (n = 511 screws) in the control group (P < 0.001). Significant differences were found regarding the accuracy of CPS placement in cases of degenerative disorders (iCT vs. control; 94% vs. 63%; P < 0.001) and trauma (iCT vs. control; 88% vs. 72%; P < 0.05). iCT yielded favorable precision rates in regard to LMS placement (iCT vs. control; 94.2% vs. 82%; P < 0.05).
CONCLUSIONS
Accuracy of iCT navigated instrumentation was significantly higher than conventional instrumentation. An overall tendency toward the use of CPSs with iCT navigation is evident, increasing the mechanical properties of the construct. iCT appears to be especially beneficial in elective surgery cases of degenerative spinal disorders.

Identifiants

pubmed: 33578024
pii: S1878-8750(21)00195-9
doi: 10.1016/j.wneu.2021.02.014
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e378-e385

Informations de copyright

Copyright © 2021 Elsevier Inc. All rights reserved.

Auteurs

Ulf Bertram (U)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany. Electronic address: ubertram@ukaachen.de.

Tobias Philip Schmidt (TP)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.

Hans Clusmann (H)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.

Walid Albanna (W)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.

Christian Herren (C)

Department of Orthopedic Trauma and Reconstructive Surgery, RWTH Aachen University, Aachen, Germany.

Alexander Riabikin (A)

Department of Neuroradiology, RWTH Aachen University, Aachen, Germany.

Christian A Mueller (CA)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.

Christian Blume (C)

Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH