3D-Printed Flexible Penile Model Simulator for Plaque Incision and Graft for Peyronie's Disease.

Corpora Cavernosa Graft Penile Curvature Peyronie's Disease Surgery Training Urologic Surgical Procedures

Journal

Sexual medicine
ISSN: 2050-1161
Titre abrégé: Sex Med
Pays: England
ID NLM: 101631053

Informations de publication

Date de publication:
Apr 2021
Historique:
received: 14 11 2020
revised: 21 12 2020
accepted: 28 12 2020
pubmed: 16 2 2021
medline: 16 2 2021
entrez: 15 2 2021
Statut: ppublish

Résumé

Plaque incision and graft (PIG) is suggested for the treatment of significant Peyronie's disease (PD), but most surgeons perform very few PIG surgeries annually, and the number of PD cases requiring PIG is inadequate to maintain the necessary skills and completely master the procedure. To develop and validate a new 3D-printed model of a curved penis and graft to simulate PIG surgery. This is the first PIG surgical training simulator described in the medical literature. A 3D-printed model of the corpora cavernosa with a 60-degree curvature and an associated urethra was created using a flexible filament of thermoplastic polyurethane. Twenty-two urologists from Brazil were recruited to perform simulated surgery on the 3D model. The participants included 12 senior-level and 10 trainee-level urologists. Evaluation of the device was based on a 15-item questionnaire using a 5-point Likert-type scale for each item. Each participant performed one simulated surgery with the 3D-printed model. All participants agreed that the simulation should be implemented into training programs. Participants ranked all content validity components ≥4.41 and all face validity components ≥3.83. The mean usability score was 4.25, and the overall experience scores were 4.75 (senior) and 5.0 (trainee). Senior and trainee urologists evaluated this first reported simulated PIG training model for penile curvature correction as an acceptable tool for training and maintaining necessary PIG skills. This model may improve PIG training and surgeon skill, thereby improving patient safety and outcomes. A Miranda. 3D-Printed Flexible Penile Model Simulator for Plaque Incision and Graft for Peyronie's Disease. Sex Med 2021;9:100318.

Identifiants

pubmed: 33588369
pii: S2050-1161(20)30206-3
doi: 10.1016/j.esxm.2020.100318
pmc: PMC8072177
pii:
doi:

Types de publication

Journal Article

Langues

eng

Pagination

100318

Informations de copyright

Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.

Références

Int J Impot Res. 2013 May;25(3):109-12
pubmed: 23344164
J Sex Med. 2016 Jun;13(6):905-23
pubmed: 27215686
Sex Med. 2016 Jun;4(2):e73-82
pubmed: 26796855
J Urol. 2004 Jun;171(6 Pt 1):2350-3
pubmed: 15126819
J Sex Med. 2020 Nov;17(11):2299-2306
pubmed: 32948488
J Sex Med. 2018 Apr;15(4):568-575
pubmed: 29550462
Eur Urol. 2012 Sep;62(3):543-52
pubmed: 22658761
Andrology. 2015 Mar;3(2):260-4
pubmed: 25331235
Int J Impot Res. 2020 May;32(3):261-263
pubmed: 31649337
Sex Med Rev. 2019 Jan;7(1):156-166
pubmed: 30301708
J Urol. 2015 Sep;194(3):745-53
pubmed: 26066402

Auteurs

Alexandre Miranda (A)

Reconstructive Urology and Andrology Section, Department of Urology, Ipanema Federal, Rio de Janeiro, Brazil. Electronic address: contato@alexandremiranda.com.br.

Classifications MeSH