Saliva as a testing specimen with or without pooling for SARS-CoV-2 detection by multiplex RT-PCR test.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2021
2021
Historique:
received:
23
11
2020
accepted:
01
02
2021
entrez:
23
2
2021
pubmed:
24
2
2021
medline:
4
3
2021
Statut:
epublish
Résumé
Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patients. Here we report the performance of QuantiVirus™ SARS-CoV-2 test using saliva as the testing specimens with or without pooling. Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical performance studies were performed with the QuantiVirus™ SARS-CoV-2 test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 test were also obtained and analyzed. Additionally, testing of pooled saliva samples was evaluated. The LOD for the QuantiVirus™ SARS-CoV-2 test was confirmed to be 100-200 copies/mL. The clinical performance studies using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus™ SARS CoV-2 test had 80% concordance rate and no significant difference (p = 0.13) between paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from local communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples (1:6 pooling) for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%). The studies demonstrated that the QuantiVirus™ SARS-CoV-2 test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™ SARS-CoV-2 test offers a highly desirable testing platform during the ongoing COVID-19 pandemic.
Sections du résumé
BACKGROUND
Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patients. Here we report the performance of QuantiVirus™ SARS-CoV-2 test using saliva as the testing specimens with or without pooling.
METHODS
Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical performance studies were performed with the QuantiVirus™ SARS-CoV-2 test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 test were also obtained and analyzed. Additionally, testing of pooled saliva samples was evaluated.
RESULTS
The LOD for the QuantiVirus™ SARS-CoV-2 test was confirmed to be 100-200 copies/mL. The clinical performance studies using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus™ SARS CoV-2 test had 80% concordance rate and no significant difference (p = 0.13) between paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from local communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples (1:6 pooling) for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%).
CONCLUSION
The studies demonstrated that the QuantiVirus™ SARS-CoV-2 test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™ SARS-CoV-2 test offers a highly desirable testing platform during the ongoing COVID-19 pandemic.
Identifiants
pubmed: 33621263
doi: 10.1371/journal.pone.0243183
pii: PONE-D-20-36825
pmc: PMC7901781
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0243183Déclaration de conflit d'intérêts
This commercial affiliation (to Diacarta Inc) does not alter our adherence to PLOS ONE policies on sharing data and materials.
Références
Lancet. 2020 Feb 15;395(10223):514-523
pubmed: 31986261
Cureus. 2020 Apr 17;12(4):e7708
pubmed: 32313785
N Engl J Med. 2020 Mar 26;382(13):1199-1207
pubmed: 31995857
N Engl J Med. 2020 Feb 20;382(8):727-733
pubmed: 31978945
J Clin Virol. 2020 Sep;130:104567
pubmed: 32750665
J Clin Microbiol. 2020 Oct 21;58(11):
pubmed: 32817233
Nature. 2020 May;581(7809):465-469
pubmed: 32235945
J Infect Dis. 2020 Aug 17;222(6):899-902
pubmed: 32594170
J Med Virol. 2021 Jan;93(1):533-536
pubmed: 32621616
Int J Oral Sci. 2020 Apr 17;12(1):11
pubmed: 32300101
Nat Med. 2020 May;26(5):672-675
pubmed: 32296168
Diagn Microbiol Infect Dis. 2021 Jan 23;100(1):115324
pubmed: 33529938
Infect Dis Poverty. 2020 Jul 22;9(1):100
pubmed: 32698862
Clin Infect Dis. 2020 Jul 28;71(15):841-843
pubmed: 32047895
Cell Prolif. 2020 Dec;53(12):e12923
pubmed: 33073910
Lancet. 2020 Feb 15;395(10223):507-513
pubmed: 32007143
J Clin Microbiol. 2020 Aug 24;58(9):
pubmed: 32636214