Ventricular tachycardia burden reduction after substrate ablation: Predictors of recurrence.
Arrhythmic burden reduction
Implantable cardioverter-defibrillator shock prevention
Ventricular tachycardia ablation
Ventricular tachycardia recurrence predictors
Ventricular tachycardia storm
Ventricular tachycardia substrate ablation
Journal
Heart rhythm
ISSN: 1556-3871
Titre abrégé: Heart Rhythm
Pays: United States
ID NLM: 101200317
Informations de publication
Date de publication:
06 2021
06 2021
Historique:
received:
24
11
2020
revised:
14
02
2021
accepted:
19
02
2021
pubmed:
28
2
2021
medline:
11
1
2022
entrez:
27
2
2021
Statut:
ppublish
Résumé
Substrate-based ventricular tachycardia (VT) ablation is a first-line treatment in patients with structural cardiac disease and sustained VT refractory to medical therapy. Despite technological improvements and increased knowledge of VT substrate, recurrence still is frequent. Published data are lacking on the possible reduction in VT burden after ablation despite recurrence. The purpose of this study was to assess VT burden reduction during long-term follow-up after substrate ablation and identify predictors of VT recurrence. We analyzed 234 consecutive VT ablation procedures in 207 patients (age 63 ± 14.9 years; 92% male; ischemic heart disease in 65%) who underwent substrate ablation in a single center from 2013 to 2018. After follow-up of 3.14 ± 1.8 years, the VT recurrence rate was 41.4%. Overall, a 99.6% reduction in VT burden (median VT episodes per year: preprocedural 3.546 [1.347-13.951] vs postprocedural 0.001 [0-0.689]; P = .001) and a 96.3% decrease in implantable cardioverter-defibrillator (ICD) shocks (preprocedural 1.145 [0.118-4.467] vs postprocedural 0.042 [0-0.111] per year; P = .017) were observed. In the subgroup of patients who experienced VT recurrences, VT burden decreased by 69.2% (median VT episodes per year: preprocedural 2.876 [1.105-8.801] vs postprocedural 0.882 [0.505-2.283]; P <.001). Multivariable analysis showed persistence of late potentials (67% vs 19%; hazard ratio 3.18 [2.18-6.65]; P <.001) and lower left ventricular ejection fraction (EF) (30 [25-40] vs 39 [30-50]; P = .022) as predictors of VT recurrence. Despite a high recurrence rate during long-term follow-up, substrate-based VT ablation is related to a large reduction in VT burden and a decrease in ICD therapies. Lower EF and persistence of late potentials are predictors of recurrence.
Sections du résumé
BACKGROUND
Substrate-based ventricular tachycardia (VT) ablation is a first-line treatment in patients with structural cardiac disease and sustained VT refractory to medical therapy. Despite technological improvements and increased knowledge of VT substrate, recurrence still is frequent. Published data are lacking on the possible reduction in VT burden after ablation despite recurrence.
OBJECTIVE
The purpose of this study was to assess VT burden reduction during long-term follow-up after substrate ablation and identify predictors of VT recurrence.
METHODS
We analyzed 234 consecutive VT ablation procedures in 207 patients (age 63 ± 14.9 years; 92% male; ischemic heart disease in 65%) who underwent substrate ablation in a single center from 2013 to 2018.
RESULTS
After follow-up of 3.14 ± 1.8 years, the VT recurrence rate was 41.4%. Overall, a 99.6% reduction in VT burden (median VT episodes per year: preprocedural 3.546 [1.347-13.951] vs postprocedural 0.001 [0-0.689]; P = .001) and a 96.3% decrease in implantable cardioverter-defibrillator (ICD) shocks (preprocedural 1.145 [0.118-4.467] vs postprocedural 0.042 [0-0.111] per year; P = .017) were observed. In the subgroup of patients who experienced VT recurrences, VT burden decreased by 69.2% (median VT episodes per year: preprocedural 2.876 [1.105-8.801] vs postprocedural 0.882 [0.505-2.283]; P <.001). Multivariable analysis showed persistence of late potentials (67% vs 19%; hazard ratio 3.18 [2.18-6.65]; P <.001) and lower left ventricular ejection fraction (EF) (30 [25-40] vs 39 [30-50]; P = .022) as predictors of VT recurrence.
CONCLUSION
Despite a high recurrence rate during long-term follow-up, substrate-based VT ablation is related to a large reduction in VT burden and a decrease in ICD therapies. Lower EF and persistence of late potentials are predictors of recurrence.
Identifiants
pubmed: 33639298
pii: S1547-5271(21)00178-8
doi: 10.1016/j.hrthm.2021.02.016