Diagnostic accuracy of EUS-guided through-the-needle-biopsies and simultaneously obtained fine needle aspiration for cytology from pancreatic cysts: A systematic review and meta-analysis.
Cyst
Cytology
Diagnostic test
Meta-analysis
Pancreas
Through-the-needle-biopsy
Journal
Pathology, research and practice
ISSN: 1618-0631
Titre abrégé: Pathol Res Pract
Pays: Germany
ID NLM: 7806109
Informations de publication
Date de publication:
Apr 2021
Apr 2021
Historique:
received:
18
12
2020
revised:
21
01
2021
accepted:
25
01
2021
pubmed:
3
3
2021
medline:
10
11
2021
entrez:
2
3
2021
Statut:
ppublish
Résumé
To address the diagnostic accuracy of endoscopic ultrasound guided through-the-needle-biopsies (TTNBs) and simultaneously obtained cytology samples from pancreatic cysts compared to the final histopathological diagnosis of the surgical specimen, and to give an overview of ancillary tests performed on TTNBs. A literature search was conducted in MEDLINE, Embase and Scopus. Studies were included in the meta-analysis, if they had data for TTNB, cytology and a surgical specimen of pancreatic cysts as reference standard. The assessment of the risk of bias and quality of the included studies was conducted using the modified QUADAS-2 tool. Ten studies with 99 patients were included in the meta-analysis. Data regarding study design and clinicopathological features were extracted systematically. For TTNB, pooled sensitivity was 0.86 (95 % CI 0.62-0.96), specificity 0.95 (95 % CI 0.79-0.99) and area under the curve (AUC) 0.86 for the diagnosis of a mucinous cyst and pooled sensitivity was 0.78 (95 % CI 0.61-0.89), specificity 0.99 (95 % CI 0.90-0.99) and AUC 0.92 for the diagnosis of a high-risk cyst. For a specific diagnosis, pooled sensitivity was 0.69 (95 % CI 0.50-0.83), specificity 0.47 (95 % CI 0.28-0.68) and AUC 0.49. For cytology performed simultaneously, pooled sensitivity was 0.46 (95 % CI 0.35-0.57), specificity 0.90 (95 % CI 0.46-0.99) and AUC 0.64 for the diagnosis of mucinous cysts, and pooled sensitivity was 0.38 (95 % CI 0.23-0.55), specificity 0.99 (95 % CI 0.90-0.99) and AUC 0.84 for the diagnosis of a high-risk cyst. For a specific diagnosis, pooled sensitivity was 0.29 (95 % CI 0.21-0.39), specificity 0.45 (95 % CI 0.25-0.66) and AUC 0.30. Furthermore, immunohistochemical stains can be useful to establish the specific cyst subtype. TTNBs have a higher sensitivity and specificity than cytology for the diagnosis of mucinous cyst and high- risk cysts of the pancreas.
Identifiants
pubmed: 33652239
pii: S0344-0338(21)00029-7
doi: 10.1016/j.prp.2021.153368
pii:
doi:
Types de publication
Journal Article
Meta-Analysis
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
153368Informations de copyright
Copyright © 2021 Elsevier GmbH. All rights reserved.