Use of carotid artery cannulation during redo sternotomy in congenital cardiac surgery: a single-centre experience.
Cardiopulmonary bypass
Carotid artery
Redo sternotomies
Journal
Interactive cardiovascular and thoracic surgery
ISSN: 1569-9285
Titre abrégé: Interact Cardiovasc Thorac Surg
Pays: England
ID NLM: 101158399
Informations de publication
Date de publication:
28 06 2021
28 06 2021
Historique:
received:
18
09
2020
revised:
09
12
2020
accepted:
20
12
2020
pubmed:
12
3
2021
medline:
25
11
2021
entrez:
11
3
2021
Statut:
ppublish
Résumé
Management of resternotomy is often a difficult challenge in patients with congenital diseases who have undergone multiple sternotomies. Our goal was to report our single-centre experience with carotid cannulation using a graft interposed during redo sternotomy in complex cardiac reintervention procedures. We performed a retrospective review of all patients who had undergone complex redo sternotomies between January 2019 and May 2020 utilizing a cervical cannulation technique with a Gore-Tex graft interposed on the carotid artery. We classified our population study on the basis of the primary diagnosis and the type of surgery. The primary outcomes of our analysis were the evaluation of the safety of the procedure in terms of survival and freedom from neurological events. We analysed 22 patients who had undergone previous complex operations. The median age and weight at the time of reintervention were 130.35 (range 0.46-435) months and 31.5 (range 2.2-85) kg, respectively. Composite graft carotid cannulation provided adequate arterial flow in all patients with a median arterial flow of 3.5 l/min/m2 (range 0.6-6). One major cardiac injury occurred during sternotomy when emergency cardiopulmonary bypass (CPB) was initiated. Moreover, during their hospital stays, all patients had an uneventful recovery without neurological or vascular complications and no cervical wound infections. Carotid cannulation using interposition of a side graft on the common carotid artery for arterial inflow is a reliable and safe method for initiation of CPB in complex redo surgeries in patients with congenital disease. Complications directly associated with this type of cannulation are uncommon and allow surgical re-entry with overall low risks.
Identifiants
pubmed: 33704457
pii: 6168155
doi: 10.1093/icvts/ivab060
pmc: PMC8691509
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
119-123Informations de copyright
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Références
World J Pediatr Congenit Heart Surg. 2012 Jul 1;3(3):373-7
pubmed: 23804872
Pediatr Crit Care Med. 2011 Jul;12(4 Suppl):S27-32
pubmed: 22129547
Ann Thorac Surg. 2017 Apr;103(4):e385-e388
pubmed: 28359507
J Thorac Cardiovasc Surg. 2003 Dec;126(6):2095-6
pubmed: 14688736
Minerva Pediatr. 2020 May 15;:
pubmed: 32418404
J Heart Lung Transplant. 2020 Jan;39(1):83-87
pubmed: 31761510
J Thorac Cardiovasc Surg. 2002 May;123(5):901-10
pubmed: 12019375
Circulation. 2014 Jan 14;129(2):224-33
pubmed: 24141323
Pediatr Crit Care Med. 2014 May;15(4):355-61
pubmed: 24622166
World J Pediatr Congenit Heart Surg. 2020 Jan;11(1):65-70
pubmed: 31835977
J Pediatr Surg. 2018 Jul;53(7):1301-1304
pubmed: 29459043
Interact Cardiovasc Thorac Surg. 2020 Jul 1;31(1):108-112
pubmed: 32236557
Stroke. 1999 Mar;30(3):514-22
pubmed: 10066845
Ann Thorac Surg. 2001 Aug;72(2):665-6
pubmed: 11515934
Ann Thorac Surg. 2012 Aug;94(2):614-20
pubmed: 22608717
J Thorac Cardiovasc Surg. 2006 Dec;132(6):1398-403
pubmed: 17140965
Ann Thorac Surg. 1996 May;61(5):1546-8
pubmed: 8633985
J Pediatr Surg. 2018 Sep;53(9):1843-1848
pubmed: 29241967