The use of an inner branch endograft for the treatment of failed chimney endovascular aortic repair.
Aneurysm
BEVAR
CHEVAR
Endoleak
Fenestration
Inner branch
Journal
Journal of vascular surgery cases and innovative techniques
ISSN: 2468-4287
Titre abrégé: J Vasc Surg Cases Innov Tech
Pays: United States
ID NLM: 101701125
Informations de publication
Date de publication:
Mar 2021
Mar 2021
Historique:
received:
13
08
2020
accepted:
20
10
2020
entrez:
15
3
2021
pubmed:
16
3
2021
medline:
16
3
2021
Statut:
epublish
Résumé
The chimney endovascular aortic repair technique is an established option for the treatment of juxtarenal aortic aneurysms. Failure of this repair represents a major surgical challenge. We report the case of a patient treated previously with chimney endovascular aortic repair (for a juxtarenal aortic aneurysm), who had developed a large type IA endoleak. The patient was treated with a custom-made endograft with three inner branches. All vessels were successfully cannulated and bridged, no evidence of endoleak was seen on the completion angiogram, and the patient had an uneventful recovery.
Identifiants
pubmed: 33718681
doi: 10.1016/j.jvscit.2020.10.015
pii: S2468-4287(20)30190-8
pmc: PMC7921176
doi:
Types de publication
Case Reports
Langues
eng
Pagination
120-122Informations de copyright
© 2020 The Authors.
Références
J Endovasc Ther. 2017 Dec;24(6):880-888
pubmed: 28914135
Int J Angiol. 2016 Dec;25(5):e126-e130
pubmed: 28031676
Br J Surg. 2013 Nov;100(12):1557-64
pubmed: 24264776
Ann Vasc Surg. 2017 Apr;40:28-38
pubmed: 28161566
J Vasc Surg. 2017 Apr;65(4):981-990
pubmed: 28189356
J Endovasc Ther. 2019 Apr;26(2):265-268
pubmed: 30764700
J Vasc Surg. 2016 Jan;63(1):1-7
pubmed: 26476671
Eur J Vasc Endovasc Surg. 2018 Sep;56(3):342-348
pubmed: 30190039