Less polyethylene wear in monobloc compared to modular ultra-high-molecular-weight-polyethylene inlays in hybrid total knee arthroplasty: A 5-year randomized radiostereometry study.
Adult
Aged
Arthroplasty, Replacement, Knee
/ adverse effects
Bone Screws
Female
Follow-Up Studies
Humans
Knee Prosthesis
/ adverse effects
Male
Middle Aged
Osteoarthritis, Knee
/ diagnostic imaging
Osteolysis
/ etiology
Polyethylenes
Prospective Studies
Prosthesis Design
Radiostereometric Analysis
Tibia
/ surgery
Titanium
Cementless
Knee arthroplasty
Modular
Monobloc
Polyethylene wear
Radiostereometry
Journal
The Knee
ISSN: 1873-5800
Titre abrégé: Knee
Pays: Netherlands
ID NLM: 9430798
Informations de publication
Date de publication:
Mar 2021
Mar 2021
Historique:
received:
29
04
2020
revised:
19
11
2020
accepted:
22
02
2021
pubmed:
21
3
2021
medline:
13
7
2021
entrez:
20
3
2021
Statut:
ppublish
Résumé
A modular polyethylene (PE) inlay in total knee arthroplasty (TKA) may wear on both sides. PE particles may induce osteolysis, which can lead to implant loosening. The aim of this study was to determine if PE wear in monobloc TKA differs from that ofmodular TKA at 60-month follow-up. In a prospective, patient-blinded trial, 50 patients were randomized to hybrid TKA surgery with either acementless high-porosity trabecular-metal tibial component with a monobloc UHMWPE inlay (MONO-TM) or a cementless low-porosity screw-augmented titanium fiber-mesh tibial component with a modular UHMWPE inlay (MODULAR-FM). Radiostereometry was used to measure PE wear and tibial component migration. At 60-monthfollow-up, mean PE wear of the medial compartment was 0.24 mm and 0.61 mm and mean PE wear of the lateral compartment was 0.31 mm and 0.82 mm for the MONO-TM and the MODULAR-FM groups, respectively (p < 0.01). The PE wear-rate was 0.05 mm (95% CI 0.03-0.08) in the MONO-TM group and 0.14 mm (95% CI 0.12-0.17) in the MODULAR-FM group (p < 0.01). Total translation at 60 months was mean 0.30 mm (95% CI 0.10-0.51) less (p < 0.01) for MONO-TM compared with MODULAR-FM tibial components. The majority of tibial components were stable (<0.2 mm MTPM) from 12 to 24-month and 24 to 60-month follow-up. At mid-term follow-up, monobloc PE inlay wear was approximately 40% of that of the modular PE inlay wear, which suggest that back-side wear of modular PE inlays is a significant contributor of PE wear in hybrid TKA.
Sections du résumé
BACKGROUND
BACKGROUND
A modular polyethylene (PE) inlay in total knee arthroplasty (TKA) may wear on both sides. PE particles may induce osteolysis, which can lead to implant loosening. The aim of this study was to determine if PE wear in monobloc TKA differs from that ofmodular TKA at 60-month follow-up.
PATIENTS AND METHODS
METHODS
In a prospective, patient-blinded trial, 50 patients were randomized to hybrid TKA surgery with either acementless high-porosity trabecular-metal tibial component with a monobloc UHMWPE inlay (MONO-TM) or a cementless low-porosity screw-augmented titanium fiber-mesh tibial component with a modular UHMWPE inlay (MODULAR-FM). Radiostereometry was used to measure PE wear and tibial component migration.
RESULTS
RESULTS
At 60-monthfollow-up, mean PE wear of the medial compartment was 0.24 mm and 0.61 mm and mean PE wear of the lateral compartment was 0.31 mm and 0.82 mm for the MONO-TM and the MODULAR-FM groups, respectively (p < 0.01). The PE wear-rate was 0.05 mm (95% CI 0.03-0.08) in the MONO-TM group and 0.14 mm (95% CI 0.12-0.17) in the MODULAR-FM group (p < 0.01). Total translation at 60 months was mean 0.30 mm (95% CI 0.10-0.51) less (p < 0.01) for MONO-TM compared with MODULAR-FM tibial components. The majority of tibial components were stable (<0.2 mm MTPM) from 12 to 24-month and 24 to 60-month follow-up.
CONCLUSION
CONCLUSIONS
At mid-term follow-up, monobloc PE inlay wear was approximately 40% of that of the modular PE inlay wear, which suggest that back-side wear of modular PE inlays is a significant contributor of PE wear in hybrid TKA.
Identifiants
pubmed: 33743263
pii: S0968-0160(21)00080-6
doi: 10.1016/j.knee.2021.02.033
pii:
doi:
Substances chimiques
Polyethylenes
0
titanium fiber
0
ultra-high molecular weight polyethylene
0
Titanium
D1JT611TNE
Types de publication
Journal Article
Randomized Controlled Trial
Langues
eng
Sous-ensembles de citation
IM
Pagination
486-499Informations de copyright
Copyright © 2021 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.