Routine abdominal magnetic resonance imaging can determine psoas muscle area in paediatric Crohn's disease and correlates with bioelectrical impedance spectroscopy measures of lean mass.
Adolescent
Anthropometry
/ methods
Body Composition
Body Weight
Child
Crohn Disease
/ diagnostic imaging
Dielectric Spectroscopy
/ methods
Electric Impedance
Female
Humans
Magnetic Resonance Imaging
/ methods
Male
Nutrition Assessment
Pelvis
Psoas Muscles
/ diagnostic imaging
Reproducibility of Results
Body composition
Crohn's disease
MRI
Nutritional assessment
Pediatrics
Sarcopenia
Journal
Clinical nutrition ESPEN
ISSN: 2405-4577
Titre abrégé: Clin Nutr ESPEN
Pays: England
ID NLM: 101654592
Informations de publication
Date de publication:
04 2021
04 2021
Historique:
received:
22
01
2021
accepted:
25
01
2021
entrez:
22
3
2021
pubmed:
23
3
2021
medline:
7
4
2021
Statut:
ppublish
Résumé
Paediatric Crohn's disease (CD) has been associated with undernutrition. Accurate and accessible measures of body composition would provide data to personalise nutritional therapy. We assessed feasibility of MRI-derived measures of psoas cross-sectional area (PCSA) in paediatric CD and correlated with anthropometric and bioelectrical impedance spectroscopy (BIS) measures. MRI small bowel/pelvis images of patients with CD, aged <18 years, were retrieved. Patients with concurrent anthropometric and BIS measurements were eligible for inclusion. The PCSA at L3 was calculated by two assessors and combined. To assess reproducibility of measures we calculated the coefficient of variation (CoV). Age, height-Z-scores, weight-Z-scores and BIS measures were correlated with PCSA. Using normal paediatric data from CT-scans we derived psoas area Z-scores for our cohort. 10 patients were included. Mean age at MRI scan was 14.6 years (11.7-16.3). PCSA was calculated for all MRI scans. There was high reproducibility between measurers, mean CoV 0.099. There was a significant positive correlation between PCSA and BIA-derived fat free mass, Pearson correlation coefficient (PCC) 0.831, p = 0.003. Correlation coefficients for PCSA and Height-for-age Z-score, weight-for-age -Z-score and age were PCC 0.343- p = 0.33, PCC = 0.222- p = 0.54, and PCC 0.6034- p = 0.065, respectively. The mean PCSA Z-score was -1.81, with 70% of the patients having a Z-score < -2.0. These data demonstrate the feasibility of deriving measures of body composition from routine MRI imagine. There was significant positive correlation between PCSA and BIS-derived lean mass. Further studies are required to confirm applicability of normal ranges prior to routine clinical implementation.
Sections du résumé
BACKGROUND
Paediatric Crohn's disease (CD) has been associated with undernutrition. Accurate and accessible measures of body composition would provide data to personalise nutritional therapy. We assessed feasibility of MRI-derived measures of psoas cross-sectional area (PCSA) in paediatric CD and correlated with anthropometric and bioelectrical impedance spectroscopy (BIS) measures.
METHODS
MRI small bowel/pelvis images of patients with CD, aged <18 years, were retrieved. Patients with concurrent anthropometric and BIS measurements were eligible for inclusion. The PCSA at L3 was calculated by two assessors and combined. To assess reproducibility of measures we calculated the coefficient of variation (CoV). Age, height-Z-scores, weight-Z-scores and BIS measures were correlated with PCSA. Using normal paediatric data from CT-scans we derived psoas area Z-scores for our cohort.
RESULTS
10 patients were included. Mean age at MRI scan was 14.6 years (11.7-16.3). PCSA was calculated for all MRI scans. There was high reproducibility between measurers, mean CoV 0.099. There was a significant positive correlation between PCSA and BIA-derived fat free mass, Pearson correlation coefficient (PCC) 0.831, p = 0.003. Correlation coefficients for PCSA and Height-for-age Z-score, weight-for-age -Z-score and age were PCC 0.343- p = 0.33, PCC = 0.222- p = 0.54, and PCC 0.6034- p = 0.065, respectively. The mean PCSA Z-score was -1.81, with 70% of the patients having a Z-score < -2.0.
CONCLUSIONS
These data demonstrate the feasibility of deriving measures of body composition from routine MRI imagine. There was significant positive correlation between PCSA and BIS-derived lean mass. Further studies are required to confirm applicability of normal ranges prior to routine clinical implementation.
Identifiants
pubmed: 33745585
pii: S2405-4577(21)00045-0
doi: 10.1016/j.clnesp.2021.01.031
pii:
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
233-238Informations de copyright
Copyright © 2021 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.