Safety of arterial catheterization using the distal radial approach in intensive care unit management: A pilot study.

Distal radial approach accidental removal arterial catheter medical device related pressure ulcer post intensive care syndrome

Journal

The journal of vascular access
ISSN: 1724-6032
Titre abrégé: J Vasc Access
Pays: United States
ID NLM: 100940729

Informations de publication

Date de publication:
Jul 2022
Historique:
pubmed: 23 3 2021
medline: 7 7 2022
entrez: 22 3 2021
Statut: ppublish

Résumé

Arterial catheter (A-line) is essential for managing severely ill patients, and the radial artery is the most common insertion site in the intensive care unit (ICU). However, many accidental removals occur because the insertion site of A-line in the traditional radial approach (TRA) overlaps with the joint flexion. Recent reports have shown no significant difference in the complication rates between coronarography using the distal radial approach (DRA) and that using TRA. However, to date, no report has examined accidental removals of DRA in the ICU. This study aimed to retrospectively evaluate the safety of the DRA A-line in ICU management. This retrospective, descriptive, and observational study enrolled patients who underwent A-line insertion using the DRA at the authors' facility, which is a university hospital with approximately 1100 beds, from January 1, 2019 to August 31, 2019. The participants' clinical data were extracted from their medical records. The primary outcome was the number of accidental removals. The study included 20 patients with a median age of 70 (interquartile range (IQR): 58.5-77) years: 10 patients with traumas, 6 with cerebral hemorrhages, 2 with gastrointestinal perforations, and 2 with other diagnoses. The number of punctures was 1 in 15 patients, 2 in 4 patients, and 3 in 1 patient. Only 1 patient required ultrasound guidance, whereas 12 patients required the use of guidewires. The median duration after insertion was 3 (IQR 2.5-5.5) days. Accidental removal was noted in only one patient. No other complications were observed during the period from insertion to removal. DRA may be a safe option for insertion of a new A-line in the ICU.

Sections du résumé

BACKGROUND UNASSIGNED
Arterial catheter (A-line) is essential for managing severely ill patients, and the radial artery is the most common insertion site in the intensive care unit (ICU). However, many accidental removals occur because the insertion site of A-line in the traditional radial approach (TRA) overlaps with the joint flexion. Recent reports have shown no significant difference in the complication rates between coronarography using the distal radial approach (DRA) and that using TRA. However, to date, no report has examined accidental removals of DRA in the ICU. This study aimed to retrospectively evaluate the safety of the DRA A-line in ICU management.
METHODS UNASSIGNED
This retrospective, descriptive, and observational study enrolled patients who underwent A-line insertion using the DRA at the authors' facility, which is a university hospital with approximately 1100 beds, from January 1, 2019 to August 31, 2019. The participants' clinical data were extracted from their medical records. The primary outcome was the number of accidental removals.
RESULTS UNASSIGNED
The study included 20 patients with a median age of 70 (interquartile range (IQR): 58.5-77) years: 10 patients with traumas, 6 with cerebral hemorrhages, 2 with gastrointestinal perforations, and 2 with other diagnoses. The number of punctures was 1 in 15 patients, 2 in 4 patients, and 3 in 1 patient. Only 1 patient required ultrasound guidance, whereas 12 patients required the use of guidewires. The median duration after insertion was 3 (IQR 2.5-5.5) days. Accidental removal was noted in only one patient. No other complications were observed during the period from insertion to removal.
CONCLUSIONS UNASSIGNED
DRA may be a safe option for insertion of a new A-line in the ICU.

Identifiants

pubmed: 33749367
doi: 10.1177/11297298211003374
doi:

Types de publication

Journal Article Observational Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

538-542

Auteurs

Marina Oi (M)

Department of Emergency and Critical Care Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.

Takaaki Maruhashi (T)

Department of Emergency and Critical Care Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.

Ai Ishikura (A)

Faculty of Nursing, Emergency and Disaster Medical Center, Kitasato University Hospital, Sagamihara, Kanagawa, Japan.

Yutaro Kurihara (Y)

Department of Emergency and Critical Care Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.

Yukiko Yaguchi (Y)

Faculty of Nursing, Emergency and Disaster Medical Center, Kitasato University Hospital, Sagamihara, Kanagawa, Japan.

Kazumasa Masuda (K)

Faculty of Nursing, Emergency and Disaster Medical Center, Kitasato University Hospital, Sagamihara, Kanagawa, Japan.

Yasushi Asari (Y)

Department of Emergency and Critical Care Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH