Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection.
Adult
Antigens, Viral
/ analysis
Asymptomatic Infections
Bias
COVID-19
/ diagnosis
COVID-19 Nucleic Acid Testing
COVID-19 Serological Testing
/ methods
Child
Cohort Studies
False Negative Reactions
False Positive Reactions
Humans
Molecular Diagnostic Techniques
/ methods
Point-of-Care Systems
Predictive Value of Tests
Reference Standards
SARS-CoV-2
/ immunology
Sensitivity and Specificity
Journal
The Cochrane database of systematic reviews
ISSN: 1469-493X
Titre abrégé: Cochrane Database Syst Rev
Pays: England
ID NLM: 100909747
Informations de publication
Date de publication:
24 03 2021
24 03 2021
Historique:
entrez:
24
3
2021
pubmed:
25
3
2021
medline:
2
4
2021
Statut:
epublish
Résumé
Accurate rapid diagnostic tests for SARS-CoV-2 infection could contribute to clinical and public health strategies to manage the COVID-19 pandemic. Point-of-care antigen and molecular tests to detect current infection could increase access to testing and early confirmation of cases, and expediate clinical and public health management decisions that may reduce transmission. To assess the diagnostic accuracy of point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. We consider accuracy separately in symptomatic and asymptomatic population groups. Electronic searches of the Cochrane COVID-19 Study Register and the COVID-19 Living Evidence Database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) were undertaken on 30 Sept 2020. We checked repositories of COVID-19 publications and included independent evaluations from national reference laboratories, the Foundation for Innovative New Diagnostics and the Diagnostics Global Health website to 16 Nov 2020. We did not apply language restrictions. We included studies of people with either suspected SARS-CoV-2 infection, known SARS-CoV-2 infection or known absence of infection, or those who were being screened for infection. We included test accuracy studies of any design that evaluated commercially produced, rapid antigen or molecular tests suitable for a point-of-care setting (minimal equipment, sample preparation, and biosafety requirements, with results within two hours of sample collection). We included all reference standards that define the presence or absence of SARS-CoV-2 (including reverse transcription polymerase chain reaction (RT-PCR) tests and established diagnostic criteria). Studies were screened independently in duplicate with disagreements resolved by discussion with a third author. Study characteristics were extracted by one author and checked by a second; extraction of study results and assessments of risk of bias and applicability (made using the QUADAS-2 tool) were undertaken independently in duplicate. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test and pooled data using the bivariate model separately for antigen and molecular-based tests. We tabulated results by test manufacturer and compliance with manufacturer instructions for use and according to symptom status. Seventy-eight study cohorts were included (described in 64 study reports, including 20 pre-prints), reporting results for 24,087 samples (7,415 with confirmed SARS-CoV-2). Studies were mainly from Europe (n = 39) or North America (n = 20), and evaluated 16 antigen and five molecular assays. We considered risk of bias to be high in 29 (50%) studies because of participant selection; in 66 (85%) because of weaknesses in the reference standard for absence of infection; and in 29 (45%) for participant flow and timing. Studies of antigen tests were of a higher methodological quality compared to studies of molecular tests, particularly regarding the risk of bias for participant selection and the index test. Characteristics of participants in 35 (45%) studies differed from those in whom the test was intended to be used and the delivery of the index test in 39 (50%) studies differed from the way in which the test was intended to be used. Nearly all studies (97%) defined the presence or absence of SARS-CoV-2 based on a single RT-PCR result, and none included participants meeting case definitions for probable COVID-19. Antigen tests Forty-eight studies reported 58 evaluations of antigen tests. Estimates of sensitivity varied considerably between studies. There were differences between symptomatic (72.0%, 95% CI 63.7% to 79.0%; 37 evaluations; 15530 samples, 4410 cases) and asymptomatic participants (58.1%, 95% CI 40.2% to 74.1%; 12 evaluations; 1581 samples, 295 cases). Average sensitivity was higher in the first week after symptom onset (78.3%, 95% CI 71.1% to 84.1%; 26 evaluations; 5769 samples, 2320 cases) than in the second week of symptoms (51.0%, 95% CI 40.8% to 61.0%; 22 evaluations; 935 samples, 692 cases). Sensitivity was high in those with cycle threshold (Ct) values on PCR ≤25 (94.5%, 95% CI 91.0% to 96.7%; 36 evaluations; 2613 cases) compared to those with Ct values >25 (40.7%, 95% CI 31.8% to 50.3%; 36 evaluations; 2632 cases). Sensitivity varied between brands. Using data from instructions for use (IFU) compliant evaluations in symptomatic participants, summary sensitivities ranged from 34.1% (95% CI 29.7% to 38.8%; Coris Bioconcept) to 88.1% (95% CI 84.2% to 91.1%; SD Biosensor STANDARD Q). Average specificities were high in symptomatic and asymptomatic participants, and for most brands (overall summary specificity 99.6%, 95% CI 99.0% to 99.8%). At 5% prevalence using data for the most sensitive assays in symptomatic people (SD Biosensor STANDARD Q and Abbott Panbio), positive predictive values (PPVs) of 84% to 90% mean that between 1 in 10 and 1 in 6 positive results will be a false positive, and between 1 in 4 and 1 in 8 cases will be missed. At 0.5% prevalence applying the same tests in asymptomatic people would result in PPVs of 11% to 28% meaning that between 7 in 10 and 9 in 10 positive results will be false positives, and between 1 in 2 and 1 in 3 cases will be missed. No studies assessed the accuracy of repeated lateral flow testing or self-testing. Rapid molecular assays Thirty studies reported 33 evaluations of five different rapid molecular tests. Sensitivities varied according to test brand. Most of the data relate to the ID NOW and Xpert Xpress assays. Using data from evaluations following the manufacturer's instructions for use, the average sensitivity of ID NOW was 73.0% (95% CI 66.8% to 78.4%) and average specificity 99.7% (95% CI 98.7% to 99.9%; 4 evaluations; 812 samples, 222 cases). For Xpert Xpress, the average sensitivity was 100% (95% CI 88.1% to 100%) and average specificity 97.2% (95% CI 89.4% to 99.3%; 2 evaluations; 100 samples, 29 cases). Insufficient data were available to investigate the effect of symptom status or time after symptom onset. Antigen tests vary in sensitivity. In people with signs and symptoms of COVID-19, sensitivities are highest in the first week of illness when viral loads are higher. The assays shown to meet appropriate criteria, such as WHO's priority target product profiles for COVID-19 diagnostics ('acceptable' sensitivity ≥ 80% and specificity ≥ 97%), can be considered as a replacement for laboratory-based RT-PCR when immediate decisions about patient care must be made, or where RT-PCR cannot be delivered in a timely manner. Positive predictive values suggest that confirmatory testing of those with positive results may be considered in low prevalence settings. Due to the variable sensitivity of antigen tests, people who test negative may still be infected. Evidence for testing in asymptomatic cohorts was limited. Test accuracy studies cannot adequately assess the ability of antigen tests to differentiate those who are infectious and require isolation from those who pose no risk, as there is no reference standard for infectiousness. A small number of molecular tests showed high accuracy and may be suitable alternatives to RT-PCR. However, further evaluations of the tests in settings as they are intended to be used are required to fully establish performance in practice. Several important studies in asymptomatic individuals have been reported since the close of our search and will be incorporated at the next update of this review. Comparative studies of antigen tests in their intended use settings and according to test operator (including self-testing) are required.
Sections du résumé
BACKGROUND
Accurate rapid diagnostic tests for SARS-CoV-2 infection could contribute to clinical and public health strategies to manage the COVID-19 pandemic. Point-of-care antigen and molecular tests to detect current infection could increase access to testing and early confirmation of cases, and expediate clinical and public health management decisions that may reduce transmission.
OBJECTIVES
To assess the diagnostic accuracy of point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. We consider accuracy separately in symptomatic and asymptomatic population groups.
SEARCH METHODS
Electronic searches of the Cochrane COVID-19 Study Register and the COVID-19 Living Evidence Database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) were undertaken on 30 Sept 2020. We checked repositories of COVID-19 publications and included independent evaluations from national reference laboratories, the Foundation for Innovative New Diagnostics and the Diagnostics Global Health website to 16 Nov 2020. We did not apply language restrictions.
SELECTION CRITERIA
We included studies of people with either suspected SARS-CoV-2 infection, known SARS-CoV-2 infection or known absence of infection, or those who were being screened for infection. We included test accuracy studies of any design that evaluated commercially produced, rapid antigen or molecular tests suitable for a point-of-care setting (minimal equipment, sample preparation, and biosafety requirements, with results within two hours of sample collection). We included all reference standards that define the presence or absence of SARS-CoV-2 (including reverse transcription polymerase chain reaction (RT-PCR) tests and established diagnostic criteria).
DATA COLLECTION AND ANALYSIS
Studies were screened independently in duplicate with disagreements resolved by discussion with a third author. Study characteristics were extracted by one author and checked by a second; extraction of study results and assessments of risk of bias and applicability (made using the QUADAS-2 tool) were undertaken independently in duplicate. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test and pooled data using the bivariate model separately for antigen and molecular-based tests. We tabulated results by test manufacturer and compliance with manufacturer instructions for use and according to symptom status.
MAIN RESULTS
Seventy-eight study cohorts were included (described in 64 study reports, including 20 pre-prints), reporting results for 24,087 samples (7,415 with confirmed SARS-CoV-2). Studies were mainly from Europe (n = 39) or North America (n = 20), and evaluated 16 antigen and five molecular assays. We considered risk of bias to be high in 29 (50%) studies because of participant selection; in 66 (85%) because of weaknesses in the reference standard for absence of infection; and in 29 (45%) for participant flow and timing. Studies of antigen tests were of a higher methodological quality compared to studies of molecular tests, particularly regarding the risk of bias for participant selection and the index test. Characteristics of participants in 35 (45%) studies differed from those in whom the test was intended to be used and the delivery of the index test in 39 (50%) studies differed from the way in which the test was intended to be used. Nearly all studies (97%) defined the presence or absence of SARS-CoV-2 based on a single RT-PCR result, and none included participants meeting case definitions for probable COVID-19. Antigen tests Forty-eight studies reported 58 evaluations of antigen tests. Estimates of sensitivity varied considerably between studies. There were differences between symptomatic (72.0%, 95% CI 63.7% to 79.0%; 37 evaluations; 15530 samples, 4410 cases) and asymptomatic participants (58.1%, 95% CI 40.2% to 74.1%; 12 evaluations; 1581 samples, 295 cases). Average sensitivity was higher in the first week after symptom onset (78.3%, 95% CI 71.1% to 84.1%; 26 evaluations; 5769 samples, 2320 cases) than in the second week of symptoms (51.0%, 95% CI 40.8% to 61.0%; 22 evaluations; 935 samples, 692 cases). Sensitivity was high in those with cycle threshold (Ct) values on PCR ≤25 (94.5%, 95% CI 91.0% to 96.7%; 36 evaluations; 2613 cases) compared to those with Ct values >25 (40.7%, 95% CI 31.8% to 50.3%; 36 evaluations; 2632 cases). Sensitivity varied between brands. Using data from instructions for use (IFU) compliant evaluations in symptomatic participants, summary sensitivities ranged from 34.1% (95% CI 29.7% to 38.8%; Coris Bioconcept) to 88.1% (95% CI 84.2% to 91.1%; SD Biosensor STANDARD Q). Average specificities were high in symptomatic and asymptomatic participants, and for most brands (overall summary specificity 99.6%, 95% CI 99.0% to 99.8%). At 5% prevalence using data for the most sensitive assays in symptomatic people (SD Biosensor STANDARD Q and Abbott Panbio), positive predictive values (PPVs) of 84% to 90% mean that between 1 in 10 and 1 in 6 positive results will be a false positive, and between 1 in 4 and 1 in 8 cases will be missed. At 0.5% prevalence applying the same tests in asymptomatic people would result in PPVs of 11% to 28% meaning that between 7 in 10 and 9 in 10 positive results will be false positives, and between 1 in 2 and 1 in 3 cases will be missed. No studies assessed the accuracy of repeated lateral flow testing or self-testing. Rapid molecular assays Thirty studies reported 33 evaluations of five different rapid molecular tests. Sensitivities varied according to test brand. Most of the data relate to the ID NOW and Xpert Xpress assays. Using data from evaluations following the manufacturer's instructions for use, the average sensitivity of ID NOW was 73.0% (95% CI 66.8% to 78.4%) and average specificity 99.7% (95% CI 98.7% to 99.9%; 4 evaluations; 812 samples, 222 cases). For Xpert Xpress, the average sensitivity was 100% (95% CI 88.1% to 100%) and average specificity 97.2% (95% CI 89.4% to 99.3%; 2 evaluations; 100 samples, 29 cases). Insufficient data were available to investigate the effect of symptom status or time after symptom onset.
AUTHORS' CONCLUSIONS
Antigen tests vary in sensitivity. In people with signs and symptoms of COVID-19, sensitivities are highest in the first week of illness when viral loads are higher. The assays shown to meet appropriate criteria, such as WHO's priority target product profiles for COVID-19 diagnostics ('acceptable' sensitivity ≥ 80% and specificity ≥ 97%), can be considered as a replacement for laboratory-based RT-PCR when immediate decisions about patient care must be made, or where RT-PCR cannot be delivered in a timely manner. Positive predictive values suggest that confirmatory testing of those with positive results may be considered in low prevalence settings. Due to the variable sensitivity of antigen tests, people who test negative may still be infected. Evidence for testing in asymptomatic cohorts was limited. Test accuracy studies cannot adequately assess the ability of antigen tests to differentiate those who are infectious and require isolation from those who pose no risk, as there is no reference standard for infectiousness. A small number of molecular tests showed high accuracy and may be suitable alternatives to RT-PCR. However, further evaluations of the tests in settings as they are intended to be used are required to fully establish performance in practice. Several important studies in asymptomatic individuals have been reported since the close of our search and will be incorporated at the next update of this review. Comparative studies of antigen tests in their intended use settings and according to test operator (including self-testing) are required.
Identifiants
pubmed: 33760236
doi: 10.1002/14651858.CD013705.pub2
pmc: PMC8078597
doi:
Substances chimiques
Antigens, Viral
0
Types de publication
Journal Article
Meta-Analysis
Research Support, Non-U.S. Gov't
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
CD013705Subventions
Organisme : World Health Organization
ID : 001
Pays : International
Commentaires et corrections
Type : UpdateOf
Type : UpdateIn
Informations de copyright
Copyright © 2021 The Authors. Cochrane Database of Systematic Reviews published by John Wiley & Sons, Ltd. on behalf of The Cochrane Collaboration.
Références
J Clin Virol. 2020 Jun;127:104383
pubmed: 32353760
Nat Commun. 2020 Dec 9;11(1):6272
pubmed: 33298935
J Infect Chemother. 2021 Feb;27(2):384-386
pubmed: 33397587
Emerg Microbes Infect. 2020 Dec;9(1):1356-1359
pubmed: 32459137
Clin Chim Acta. 2020 Nov;510:685-686
pubmed: 32910978
Diagn Microbiol Infect Dis. 2020 Oct;98(2):115123
pubmed: 32673978
J Clin Virol. 2020 Jul;128:104426
pubmed: 32417674
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32393482
J Biomol Tech. 2021 Sep;32(3):137-147
pubmed: 35035293
J Clin Virol. 2020 Oct;131:104612
pubmed: 32871543
Nat Commun. 2020 Sep 23;11(1):4812
pubmed: 32968075
Clin Chem Lab Med. 2020 Jun 29;58(9):1587-1593
pubmed: 32598302
J Med Virol. 2021 May;93(5):3152-3157
pubmed: 33615487
Clin Microbiol Infect. 2021 Feb;27(2):289.e1-289.e4
pubmed: 33031947
Travel Med Infect Dis. 2021 Jan-Feb;39:101942
pubmed: 33278609
Kathmandu Univ Med J (KUMJ). 2020 COVID-19 SPECIAL ISSUE;18(70):36-39
pubmed: 33605236
ACS Omega. 2020 Oct 13;5(42):27433-27441
pubmed: 33134706
Cochrane Database Syst Rev. 2020 Jun 25;6:CD013652
pubmed: 32584464
J Clin Microbiol. 2021 Mar 19;59(4):
pubmed: 33441395
Nat Commun. 2020 Sep 18;11(1):4711
pubmed: 32948757
PLoS Med. 2009 Jul 21;6(7):e1000097
pubmed: 19621072
J Clin Virol. 2020 Jul;128:104416
pubmed: 32388470
J Appl Lab Med. 2020 Nov 1;5(6):1307-1312
pubmed: 32761092
J Clin Virol. 2020 Nov;132:104654
pubmed: 33053494
Anal Chem. 2020 Oct 20;92(20):14139-14144
pubmed: 32967427
Clin Chem. 2020 Aug 1;66(8):1047-1054
pubmed: 32384153
Ann Intern Med. 2020 Sep 15;173(6):450-460
pubmed: 32496919
J Clin Microbiol. 2021 Apr 20;59(5):
pubmed: 33622768
J Virol Methods. 2020 Dec;286:113965
pubmed: 32891677
EClinicalMedicine. 2021 Jun;36:100924
pubmed: 34101770
RSC Adv. 2020 Sep 23;10(58):35257-35264
pubmed: 35515699
Nat Commun. 2020 Nov 20;11(1):5920
pubmed: 33219228
PLoS One. 2020 Aug 13;15(8):e0237418
pubmed: 32790779
Genes (Basel). 2020 Oct 12;11(10):
pubmed: 33053675
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32503847
J Infect Dis. 2021 Apr 8;223(7):1139-1144
pubmed: 33394052
Int J Mol Sci. 2020 Jul 29;21(15):
pubmed: 32751106
JAMA. 2018 Jan 23;319(4):388-396
pubmed: 29362800
Public Health. 2020 May;182:170-172
pubmed: 32334183
Pathogens. 2021 Jan 05;10(1):
pubmed: 33466537
J Med Microbiol. 2020 Sep;69(9):1169-1178
pubmed: 32755529
Clin Chem. 2020 Jul 1;66(7):977-979
pubmed: 32282874
J Clin Virol. 2020 Jul;128:104429
pubmed: 32425657
J Clin Virol. 2020 Oct;131:104614
pubmed: 32889495
J Clin Virol. 2020 Jul;128:104454
pubmed: 32485473
J Clin Virol. 2020 Sep;130:104578
pubmed: 32777761
J Clin Virol. 2020 Jul;128:104387
pubmed: 32380382
Arch Pathol Lab Med. 2020 Nov 1;144(11):1303-1310
pubmed: 32649229
Ann Intern Med. 2011 Oct 18;155(8):529-36
pubmed: 22007046
J Virol Methods. 2021 Sep;295:114199
pubmed: 34091213
J Clin Virol. 2020 Aug;129:104500
pubmed: 32585619
Front Cell Infect Microbiol. 2020 Jun 16;10:331
pubmed: 32626666
Cochrane Database Syst Rev. 2021 Feb 23;2:CD013665
pubmed: 33620086
Lancet Infect Dis. 2021 Jun;21(6):e163-e169
pubmed: 33301725
J Proteins Proteom. 2020;11(3):159-165
pubmed: 33132628
J Infect. 2020 Sep;81(3):e75-e78
pubmed: 32579988
Clin Chem. 2020 Jul 1;66(7):975-977
pubmed: 32315390
Microb Biotechnol. 2020 Jul;13(4):950-961
pubmed: 32333644
J Clin Virol. 2020 Sep;130:104567
pubmed: 32750665
Clin Microbiol Infect. 2021 Mar;27(3):487-488
pubmed: 32979567
BMC Infect Dis. 2020 Oct 20;20(1):783
pubmed: 33081710
Lancet Infect Dis. 2021 May;21(5):629-636
pubmed: 33545090
Transfusion. 2020 Dec;60(12):2952-2961
pubmed: 32798248
mSphere. 2020 Aug 26;5(4):
pubmed: 32848011
Am J Clin Pathol. 2020 Jul 7;154(2):201-207
pubmed: 32462195
Innovation (Camb). 2020 Nov 25;1(3):100061
pubmed: 33169119
Emerg Microbes Infect. 2020 Dec;9(1):998-1007
pubmed: 32306853
Sci Rep. 2021 Feb 3;11(1):2936
pubmed: 33536475
ACS Nano. 2020 Apr 28;14(4):5135-5142
pubmed: 32293168
Biosens Bioelectron. 2021 Jul 1;183:113207
pubmed: 33866136
Nat Microbiol. 2020 Oct;5(10):1299-1305
pubmed: 32651556
Diagnostics (Basel). 2020 Aug 14;10(8):
pubmed: 32823866
Cochrane Database Syst Rev. 2020 Sep 30;9:CD013639
pubmed: 32997361
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32327448
Sci Bull (Beijing). 2020 Sep 15;65(17):1436-1439
pubmed: 32373393
J Clin Virol. 2020 Jul;128:104390
pubmed: 32388471
PLoS Biol. 2021 Apr 29;19(4):e3001216
pubmed: 33914730
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32444354
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32414838
Jpn J Infect Dis. 2021 Jan 22;74(1):29-34
pubmed: 32611983
J Clin Epidemiol. 2005 Oct;58(10):982-90
pubmed: 16168343
Cell Rep Med. 2020 Aug 25;1(5):100062
pubmed: 32838340
Biosens Bioelectron. 2021 May 15;180:113111
pubmed: 33743492
Lab Chip. 2020 Jun 21;20(12):2075-2085
pubmed: 32490853
J Virol Methods. 2020 Oct;284:113925
pubmed: 32659240
J Clin Virol. 2020 Dec;133:104659
pubmed: 33160179
Virology. 2020 Oct;549:1-4
pubmed: 32758712
Clin Microbiol Infect. 2021 Mar;27(3):472.e7-472.e10
pubmed: 33189872
Dis Markers. 2020 Dec 9;2020:8869424
pubmed: 33343767
J Virol Methods. 2020 Nov;285:113970
pubmed: 32920028
Indian J Med Res. 2021 Jan & Feb;153(1 & 2):126-131
pubmed: 33818469
J Clin Virol. 2020 Oct;131:104593
pubmed: 32823131
Biosens Bioelectron. 2021 Jan 1;171:112685
pubmed: 33113383
Rev Chilena Infectol. 2020 Jun;37(3):276-280
pubmed: 32853320
J Clin Microbiol. 2018 Jul 26;56(8):
pubmed: 29898998
Open Forum Infect Dis. 2020 Dec 21;8(2):ofaa631
pubmed: 34853795
Lancet Microbe. 2021 Jan;2(1):e13-e22
pubmed: 33521734
Front Med (Lausanne). 2020 May 08;7:225
pubmed: 32574326
J Infect Dis. 2021 Feb 3;223(2):206-213
pubmed: 33535237
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32461285
J Clin Microbiol. 2020 Dec 17;59(1):
pubmed: 33051242
Virol Sin. 2020 Jun;35(3):344-347
pubmed: 32239445
J Clin Microbiol. 2021 Jan 21;59(2):
pubmed: 33139420
BMJ. 2020 Dec 11;371:m4787
pubmed: 33310701
Lancet Public Health. 2020 Aug;5(8):e452-e459
pubmed: 32682487
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32303565
Int J Infect Dis. 2020 Oct;99:397-402
pubmed: 32800855
Biosens Bioelectron. 2020 Oct 15;166:112437
pubmed: 32692666
PLoS One. 2020 Jun 12;15(6):e0234682
pubmed: 32530929
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32332061
Nat Biotechnol. 2020 Oct;38(10):1168-1173
pubmed: 32733106
Clin Med (Lond). 2021 Jan;21(1):e54-e56
pubmed: 33243836
J Clin Virol. 2020 Jul;128:104428
pubmed: 32434706
Cochrane Database Syst Rev. 2020 Aug 26;8:CD013705
pubmed: 32845525
J Clin Virol. 2020 Aug;129:104455
pubmed: 32485618
BMJ. 2021 Feb 3;372:n208
pubmed: 33536228
J Infect. 2021 May;82(5):186-230
pubmed: 33421447
PLoS Med. 2012;9(9):e1001306
pubmed: 22973183
Nat Med. 2020 Aug;26(8):1224-1228
pubmed: 32427924
Cell Rep Med. 2020 Sep 22;1(6):100099
pubmed: 32905045
J Clin Virol. 2020 Aug;129:104427
pubmed: 32535398
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32366669
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32303564
Biosens Bioelectron. 2020 Dec 1;169:112642
pubmed: 32979593
PLoS One. 2020 Dec 10;15(12):e0242958
pubmed: 33301459
Clin Microbiol Infect. 2020 Jun;26(6):773-779
pubmed: 32276116
J Med Virol. 2021 May;93(5):3069-3076
pubmed: 33554363
J Clin Virol. 2020 Nov;132:104616
pubmed: 32891938
Biochip J. 2019;13(4):341-351
pubmed: 32226589
J Clin Microbiol. 2020 Aug 24;58(9):
pubmed: 32611796
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32461287
Stat Methods Med Res. 2017 Aug;26(4):1896-1911
pubmed: 26116616
Cochrane Database Syst Rev. 2020 Nov 19;11:CD013787
pubmed: 33211319
N Engl J Med. 2020 Oct 8;383(15):1492-1494
pubmed: 32937062
Ann Intern Med. 2020 Aug 18;173(4):262-267
pubmed: 32422057
J Clin Microbiol. 2017 Aug;55(8):2313-2320
pubmed: 28539345
Clin Infect Dis. 2021 Jun 1;72(11):e921
pubmed: 32986798
J Clin Virol. 2020 Aug;129:104472
pubmed: 32504944
Nat Biomed Eng. 2020 Dec;4(12):1140-1149
pubmed: 32848209
Malar J. 2018 May 18;17(1):206
pubmed: 29776359
Acad Emerg Med. 2020 Aug;27(8):764-766
pubmed: 32492760
Clin Microbiol Infect. 2020 Aug;26(8):1076-1081
pubmed: 32422410
ACS Cent Sci. 2021 Feb 24;7(2):307-317
pubmed: 33649735
Anal Chem. 2020 Jul 21;92(14):9699-9705
pubmed: 32441935
Proc Natl Acad Sci U S A. 2020 Sep 29;117(39):24450-24458
pubmed: 32900935
Clin Microbiol Infect. 2020 Dec;26(12):1699-1700
pubmed: 32735938
Emerg Infect Dis. 2020 Oct;26(10):2401-2405
pubmed: 32610037
Lancet Microbe. 2020 Nov;1(7):e300-e307
pubmed: 32964211
Eur J Microbiol Immunol (Bp). 2020 Aug 17;10(3):156-164
pubmed: 32804668
PLoS One. 2020 Oct 20;15(10):e0241029
pubmed: 33079951
J Clin Virol. 2020 Sep;130:104579
pubmed: 32795959
Cochrane Database Syst Rev. 2020 Nov 26;11:CD013639
pubmed: 33242342
J Clin Microbiol. 2021 May 19;59(6):
pubmed: 33782112
Eur J Clin Microbiol Infect Dis. 2020 Aug;39(8):1601-1603
pubmed: 32270412
Diagn Microbiol Infect Dis. 2021 Jan;99(1):115200
pubmed: 32980807
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32471894
Euro Surveill. 2020 Mar;25(9):
pubmed: 32156329
Proc Natl Acad Sci U S A. 2020 Sep 15;117(37):22727-22735
pubmed: 32868442
J Virol Methods. 2021 Mar;289:114048
pubmed: 33358911
J Clin Microbiol. 2020 Aug 24;58(9):
pubmed: 32636214
Genes (Basel). 2020 Jun 18;11(6):
pubmed: 32570810
J Clin Microbiol. 2020 Dec 17;59(1):
pubmed: 33023911
Biochem Biophys Res Commun. 2020 Jun 30;527(3):618-623
pubmed: 32416961
Int J Environ Res Public Health. 2020 Jan 15;17(2):
pubmed: 31952364
Nat Commun. 2020 Nov 20;11(1):5921
pubmed: 33219225
J Clin Epidemiol. 1999 Dec;52(12):1231-7
pubmed: 10580787
Cell Rep Med. 2020 Oct 20;1(7):100123
pubmed: 32995758
Clin Microbiol Infect. 2021 Jan;27(1):128.e1-128.e7
pubmed: 32979576
Cell Host Microbe. 2020 Jun 10;27(6):992-1000.e3
pubmed: 32320677
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32404480
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32350048
Euro Surveill. 2020 Mar;25(9):
pubmed: 32156330
Int J Mol Sci. 2020 Apr 18;21(8):
pubmed: 32325642
ACS Cent Sci. 2020 May 27;6(5):591-605
pubmed: 32382657
EClinicalMedicine. 2021 Jan;31:100677
pubmed: 33521610
Nat Commun. 2021 Mar 5;12(1):1467
pubmed: 33674580
Int J Infect Dis. 2020 Oct;99:328-333
pubmed: 32497809
J Clin Microbiol. 2020 Jul 23;58(8):
pubmed: 32341142
Sci Adv. 2021 Jan 1;7(1):
pubmed: 33219112
Euro Surveill. 2020 Aug;25(32):
pubmed: 32794447
J Virol Methods. 2020 Dec;286:113972
pubmed: 32941977
BMJ. 2015 Oct 28;351:h5527
pubmed: 26511519