Cerebral and splanchnic oxygenation during automated control of inspired oxygen (FiO
automated control
cerebral
oxygen
oxygenation
preterm infant
splanchnic
Journal
Pediatric pulmonology
ISSN: 1099-0496
Titre abrégé: Pediatr Pulmonol
Pays: United States
ID NLM: 8510590
Informations de publication
Date de publication:
07 2021
07 2021
Historique:
revised:
17
02
2021
received:
27
10
2020
accepted:
05
03
2021
pubmed:
28
3
2021
medline:
25
11
2021
entrez:
27
3
2021
Statut:
ppublish
Résumé
Our aim in this study was to assess the effect of the Predictive Intelligent Control of Oxygenation (PRICO Twenty infants with gestational age <32 weeks (n = 20) were assigned in random sequence to 12 h of automated or manual adjustment of FiO We found that rSO Automated control of FiO
Substances chimiques
Oxygen
S88TT14065
Types de publication
Journal Article
Randomized Controlled Trial
Langues
eng
Sous-ensembles de citation
IM
Pagination
2067-2072Informations de copyright
© 2021 Wiley Periodicals LLC.
Références
Manja V , Saugstad OD , Lakshminrusimha S . Oxygen saturation targets in preterm infants and outcomes at 18-24 months: a systematic review. Pediatrics. 2017;139:e20161609.
Hwang JS , Rehan VK . Recent advances in bronchopulmonary dysplasia: pathophysiology, prevention, and treatment. Lung. 2018;196:129-138.
Dogra MR , Katoch D , Dogra M . An update on retinopathy of prematurity (ROP). Indian J Pediatr. 2017;84:930-936.
Cummings JJ , Polin RA , Committee on fetus and newborn. Oxygen targeting in extremely low birth weight infants. Pediatrics. 2016;138:e20161576.
Sweet DG , Carnielli V , Greisen G , et al. European consensus guidelines on the management of respiratory distress syndrome-2019 update. Neonatology. 2019;115:432-450.
Schmidt B , Whyte RK , Canadian Oxygen Trial(COT) Group, et al. Effects of targeting higher or lower oxygen saturations in centers with more versus less seperation between median saturations. J Pediatr. 2016;178:288-291 e2.
Tarnow-Mordi W , Stenson B , BOOST-II Australia and United Kingdom Collaborative Groups , et al. Outcomes of two trials of oxygen saturation targets in preterm infants. N Engl J Med. 2016;374:749-760.
Stenson BJ , Tarnow-Mordi WO , Darlow BA , et al. Oxygen saturation and outcomes in preterm infants. N Engl J Med. 2013;368:2094-2104.
Carlo WA , Finer NN , Walsh MC , et al. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med. 2010;362:1959-1969.
Poets CF , Roberts RS , Schmidt B , et al. Association between intermittent hypoxiemia and bradycardia and late death or disability in extremely preterm infants. JAMA. 2015;314:595-603.
Dani C . Automated control of inspired oxygen (FiO2) in preterm infants: literature review. Pediatr Pulmonol. 2019;54:358-363.
Waitz M , Schmid MB , Fuchs H , Mendler MR , Dreyhaupt J , Hummler HD . Effects of automated adjustment of the inspired oxygen on fluctuations of arterial and regional cerebral tissue oxygenation in preterm infants with frequent desaturations. J Pediatr. 2015;166:240-244.
Gajdos M , Waitz M , Mendler MR , Braun W , Hummler H . Effects of a new device for automated closed loop control of inspired oxygen concentration on fluctuations of arterial and different regional organ tissue oxygen saturations in preterm infants. Arch Dis Child Fetal Neonatal Ed. 2019;104:F360-F365.
Fathabadi OS , Gale TJ , Dargaville PA . Automated control of inspired oxygen for preterm infants: What we have and what we need. Biomed Signal Process Control. 2016;28:9-18.
Hütten MC , Goos TG , Ophelders D , et al. Fully automated predictive intelligent control of oxygenation (PRICO) in resuscitation and ventilation of preterm lambs. Pediatr Res. 2015;78:657-663.
Wardle SP , Yoxall CW , Weindling AM . Determinants of cerebral fractional oxygen extraction using near infrared spectroscopy in preterm neonates. J Cereb Blood Flow Metab. 2000;20:272-279.
Fortune PM , Wagstaff M , Petros AJ . Cerebro splanchnic oxygenation ratio (CSOR) using near infrared spectroscopy may be able to predict splanchnic ischaemia in neonates. Intensive Care Med. 2001;27:1410-1417.
Ehrenkranz RA . Validation of the National Institutes of Health consensus definition of bronchopulmonary dysplasia. Pediatrics. 2005;16:1353-1360.
Bell MJ , Ternberg JL , Feigin RD , et al. Neonatal necrotizing enterocolitis: therapeutic decisions based on clinical staging. Ann Surg. 1978;187:1-7.
Papile LS , Burstein J , Burstein R , Koffler H . Incidence and evolution of the subependymal intraventricular hemorrhage: a study of infants weighing less than 1500 grams. J Pediatr. 1978;92:529-534.
The International Classification of Retinopathy of Prematurity revisited. The international classification of retinopathy of prematurity revisited. Arch Ophthalmol. 2005;123:991-999.
Claure N , Bancalari E . Automated closed loop control of inspired oxygen concentration. Respir Care. 2013;58:151-161.
Dani C , Pratesi S , Barp J , et al. Near-infrared spectroscopy measurements of splanchnic tissue oxygenation during continuous versus intermittent feeding method in preterm infants. J Pediatr Gastroenterol Nutr. 2013;56:652-656.
Poets CF , Franz AR . Automated FiO2 control: nice to have, or an essential addition to neonatal intensive care? Arch Dis Child Fetal Neonatal Ed. 2017;102:F5-F6.
Poets CF , Roberts RS , Schmidt B , et al. Association between intermittent hypoxemia or bradycardia and late death or disability in extremely preterm infants. JAMA. 2015;314:595-603.