Résumé
The use of pediatric computed tomography (CT), a valuable imaging tool, has been increasing rapidly. The present study examined radiation exposure in non-irradiated fields of CT scans in pediatric patients using a 7-year-old child phantom. Radio-photoluminescence glass dosimeters were placed in the insertion ports of the phantom corresponding to the organs. For the helical and the non-helical scans, the doses to the head in the irradiation field were 54.6 mGy and 53.4 mGy, respectively. The dose measured for the helical scan was 2.3% higher than that for the non-helical scan. The largest dose was in the thyroid gland, and the doses for helical and non-helical scans were 5.37 mGy and 3.58 mGy, respectively. The difference in the dose between helical and non-helical scans was 1.79 mGy. The dose measured for the helical scan was 50% higher than that for the non-helical scan. The dose to which the thyroid gland was exposed outside the irradiation field in the head CT scan was 5.37 mGy using the helical scan method. The excess relative risk per gray increased by 3-5.5% if the excess relative risk per gray was 5-10. Decreasing the dose to the thyroid gland, which has a high risk of cancer after radiation exposure, is desirable. The dose to the thyroid gland was higher in the helical scan than in the non-helical scan. This is probably because overscanning, which is unique to helical scanning, increases the exposure dose outside the irradiation field.
Identifiants
pubmed: 33783725
doi: 10.1007/s12194-021-00614-6
pii: 10.1007/s12194-021-00614-6
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
173-178Références
International Commission on Radiological Protection (ICRP). Managing Patient Dose in Computed Tomography. ICRP Publication 87. Ann. 2000: ICRP 30 (4).
Organisation for Economic Co-operation and Development (OECD). OECD Health Statistics 2020. OECD. Stat, Health Care Resources: Medical technology, https://stats.oecd.org/Index.aspx?QueryId=30184 , (accessed 2020–11–20).
United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources and effects of ionizing radiation. Report to the General Assembly of the United Nations with Scientific Annexes, Annex D: Medical radiation exposures, United Nations sales publication. 2000: New York.
United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources and effects of ionizing radiation. UNSCEAR 2013 Report. Volume II. Scientific Annex B: Effects of radiation exposure of children. United Nations sales publication E.14.IX.2. United Nations, New York 2013.
Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation and National Research Council. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. 2006: The National Academies Press; Washington, D.C.
Chodick G, Ronckers CM, Shalev V, Ron E. Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children. Isr Med Assoc J. 2007;8:584–7.
Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, et al. Pediatric computed tomography and associated radiation exposure and estimated cancer risk. JAMA Pediatr. 2013;167:700–7.
doi: 10.1001/jamapediatrics.2013.311
Gao Y, Quinn B, Mahmood U, Long D, Erdi Y, Germain J, et al. A comparison of pediatric and adult CT organ dose estimation methods. BMC Med Imaging. 2017;17:28.
doi: 10.1186/s12880-017-0199-3
Gao Y, Quinn B, Pandit-Taskar N, Behr G, Mahmood U, Long D, et al. Patient-specific organ and effective dose estimates in pediatric oncology computed tomography. Phys Med. 2018;45:146–55.
doi: 10.1016/j.ejmp.2017.12.013
Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380:499–505.
doi: 10.1016/S0140-6736(12)60815-0
Mathews JD, Forsythe AV, Brady Z, Butler MW, Goergen SK, Byrnes GB, et al. Cancer risk in 680 000 people exposed to compute tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ. 2013;346:F2360.
doi: 10.1136/bmj.f2360
Miyazaki O, Horiuchi T. Pediatric CT Practice. Journal of Japanese Society of Pediatric Radiology. 2006;22:33–43.
ICRU report 44: Tissue Substitutes in Radiation Dosimetry and Measurement, ICRU, Bethesda, Maryland, 1989.
Hiraoka T. Basic data for phantom materials, (1) Radiation therapy phantom. Medical Standard DOSE. 1999;4(1):23–8 ((in Japanese)).
Hiraoka T. Basic data for phantom materials, (2) Mass attenuation coefficients, Vol.4 No.2, 17–23, 1999. (in Japanese)
Hiraoka T. Basic data for phantom materials, (3) Mass absorption coefficients, Vol.4 No.2, 25–31, 1999. (in Japanese)
Hiraoka T. Basic data for phantom materials, (4) Stopping power and Limited stopping power, Vol.5 No.1, 33–63, 2000. (in Japanese)
Japan Network for Research and Information on Medical Exposures (J-RIME). National diagnostic reference levels in Japan (2020). Japan DRLs 2020. http://www.radher.jp/J-RIME/report/JapanDRL2020_jp.pdf
Kodera S. Photographing technique of head CT. From basic to clinical. RT.2007:38:71–76. (in Japanese).
Banno T. Usefulness for the radiation exposure reduction of synchronization asymmetry Z-axis collimation at the time of the helical scan. Tohoku Journal of Radiological Technology. 2012;21:112–3 ((in Japanese)).
Preston DL, Ron E, Tokuoka S, Funamoto S, Nishi N, Soda M, et al. Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998. Radiat Res. 2007;168:1–64.
doi: 10.1667/RR0763.1
Ron E, Lubin JH, Shore RE, Mabuchi K, Modan B, Pottern LM, Schneider AB, Tucker MA, Boice JD Jr. Thyroid cancer after exposure to external radiation: a pooled analysis of seven studies. Radiat Res. 1995;141:259–77.
doi: 10.2307/3579003
Tzedakis A, Damilakis J, Perisinakis K, Stratakis J, Gourtsoyiannis N. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations. Med Phys. 2005;32:1621–9.
doi: 10.1118/1.1924309
Tzedakis A, Damilakis J, Perisinakis K, Karantanas A, Karabekios S, Gourtsoyiannis N. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations. Med Phys. 2007;34:1163–75.
doi: 10.1118/1.2710331