A review of new adsorbents for separation of BTEX biomarkers.


Journal

Biomedical chromatography : BMC
ISSN: 1099-0801
Titre abrégé: Biomed Chromatogr
Pays: England
ID NLM: 8610241

Informations de publication

Date de publication:
Sep 2021
Historique:
revised: 17 03 2021
received: 08 01 2021
accepted: 26 03 2021
pubmed: 1 4 2021
medline: 29 9 2021
entrez: 31 3 2021
Statut: ppublish

Résumé

The biomarker analysis of benzene, toluene, ethylbenzene and xylene (BTEXs) in biological samples is the primary technique for evaluating these compounds in occupational and environmental exposures. The BTEX biomarkers are widely used to study the BTEX distribution in the environment and workplaces. Liquid-liquid extraction and solid-phase liquid extraction are among the most commonly used conventional methods to analyze biological indices of BTEXs. New methods have been proposed to analyze BTEX biomarkers using novel adsorbents such as sol-gel composite nanotubes, molecularly imprinted polymers and metal-organic frameworks, which are based on the application of needle trap devices, microextraction by packed sorbent, and solid-phase microextraction techniques. This paper provides an overview of new methods since 2015 regarding applying microextraction methods based on new adsorbents and analyzing BTEX biomarker compounds for occupational and environmental exposures. The results were compared with the liquid-phase microextraction methods recommended for urinary BTEX biomarkers.

Identifiants

pubmed: 33788293
doi: 10.1002/bmc.5131
doi:

Substances chimiques

Benzene Derivatives 0
Biomarkers 0
Disaccharides 0
Glucuronates 0
O-(glucuronic acid 2-sulfate)-(1--4)-O-(2,5)-anhydromannitol 6-sulfate 98632-68-9

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

e5131

Informations de copyright

© 2021 John Wiley & Sons, Ltd.

Références

Abdel-Rehim, M. (2004). New trend in sample preparation: On-line microextraction in packed syringe for liquid and gas chromatography applications: I. determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry. Journal of Chromatography B, 801(2), 317-321. https://doi.org/10.1016/j.jchromb.2003.11.042
Amorim, L. C., Carneiro, J. P., & Cardeal, Z. L. (2008). An optimized method for determination of benzene in exhaled air by gas chromatography-mass spectrometry using solid phase microextraction as a sampling technique. Journal of Chromatography B, 865(1-2), 141-146. https://doi.org/10.1016/j.jchromb.2008.02.023
Aranda-Rodriguez, R., Cabecinha, A., Harvie, J., Jin, Z., Marchand, A., Tardif, R., Nong, A., & Haddad, S. (2015). A method for quantification of volatile organic compounds in blood by SPME-GC-MS/MS with broader application: From non-occupational exposure population to exposure studies. Journal of Chromatography B, 992, 76-85. https://doi.org/10.1016/j.jchromb.2015.04.020
Banihashemi, S., & Bagheri, H. (2017). A core-shell titanium dioxide polyaniline nanocomposite for the needle-trap extraction of volatile organic compounds in urine samples. Journal of Separation Science, 40(9), 1985-1992. https://doi.org/10.1002/jssc.201600970
Bello-López, M. Á., Ramos-Payán, M., Ocaña-González, J. A., Fernández-Torres, R., & Callejón-Mochón, M. (2012). Analytical applications of hollow fiber liquid phase microextraction (HF-LPME): A review. Analytical Letters, 45(8), 804-830. https://doi.org/10.1080/00032719.2012.655676
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016). Molecular imprinting: Perspectives and applications. Chemical Society Reviews, 45(8), 2137-2211. https://doi.org/10.1039/C6CS00061D
Cherrie, J. W., Semple, S., Christopher, Y., Saleem, A., Hughson, G. W., & Philips, A. (2006). How important is inadvertent ingestion of hazardous substances at work? The Annals of Occupational Hygiene, 50(7), 693-704. https://doi.org/10.1093/annhyg/mel035
de la Calle, I., Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2016). Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review. Analytica Chimica Acta, 936, 12-39. https://doi.org/10.1016/j.aca.2016.06.046
Díaz, U., & Corma, A. (2016). Ordered covalent organic frameworks, COFs and PAFs. From preparation to application. Coordination Chemistry Reviews, 311, 85-124. https://doi.org/10.1016/j.ccr.2015.12.010
Furukawa, H., Cordova, K. E., O'Keeffe, M., & Yaghi, O. M. (2013). The chemistry and applications of metal-organic frameworks. Science, 341(6149), 1230444. https://doi.org/10.1126/science.1230444
Ghamari, F., Bahrami, A., Yamini, Y., Shahna, F. G., & Moghimbeigi, A. (2016). Development of hollow-fiber liquid-phase microextraction method for determination of urinary trans,trans-muconic acid as a biomarker of benzene exposure. Analytical Chemistry Insights, 11, ACI. S40177.
Ghamari, F., Bahrami, A., Yamini, Y., Shahna, F. G., & Moghimbeigi, A. (2017). Hollow-fiber liquid-phase microextraction based on carrier-mediated transport for determination of urinary methyl hippuric acids. Toxicological & Environmental Chemistry, 99(5-6), 760-771. https://doi.org/10.1080/02772248.2017.1280038
González, J. L., Pell, A., López-Mesas, M., & Valiente, M. (2017). Simultaneous determination of BTEX and their metabolites using solid-phase microextraction followed by HPLC or GC/MS: An application in teeth as environmental biomarkers. Science of the Total Environment, 603, 109-117.
González, J. L., Pell, A., López-Mesas, M., & Valiente, M. (2018). Hollow fibre supported liquid membrane extraction for BTEX metabolites analysis in human teeth as biomarkers. Science of the Total Environment, 630, 323-330. https://doi.org/10.1016/j.scitotenv.2018.02.195
Gottzein, A. K., Musshoff, F., & Madea, B. (2010). Qualitative screening for volatile organic compounds in human blood using solid-phase microextraction and gas chromatography-mass spectrometry. Journal of Mass Spectrometry, 45(4), 391-397. https://doi.org/10.1002/jms.1723
Háková, M., Havlíková, L. C., Chvojka, J., Erben, J., Solich, P., Švec, F., & Šatínský, D. (2018). A comparison study of nanofiber, microfiber, and new composite nano/microfiber polymers used as sorbents for on-line solid phase extraction in chromatography system. Analytica Chimica Acta, 1023, 44-52. https://doi.org/10.1016/j.aca.2018.04.023
Hamidi, S., Alipour-Ghorbani, N., & Hamidi, A. (2018). Solid phase microextraction techniques in determination of biomarkers. Critical Reviews in Analytical Chemistry, 48(4), 239-251. https://doi.org/10.1080/10408347.2017.1396885
Heibati, B., Pollitt, K. J. G., Charati, J. Y., Ducatman, A., Shokrzadeh, M., Karimi, A., & Mohammadyan, M. (2018). Biomonitoring-based exposure assessment of benzene, toluene, ethylbenzene and xylene among workers at petroleum distribution facilities. Ecotoxicology and Environmental Safety, 149, 19-25. https://doi.org/10.1016/j.ecoenv.2017.10.070
Hill, HM. (2003). Chromatography in a regulated environment. Handbook of Analytical Separations (Vol. 4, pp. 373-411). Elsevier.
Iijima, S. (1991). Helical microtubules of graphitic carbon. Nature, 354(6348), 56-58.
Jakubowski, M. (2012). Biological monitoring versus air monitoring strategies in assessing environmental-occupational exposure. Journal of Environmental Monitoring, 14(2), 348-352. https://doi.org/10.1039/C1EM10706B
Jalali, M., Sakhvid, M. J. Z., Bahrami, A., Berijani, N., & Mahjub, H. (2016). Oxidative stress biomarkers in exhaled breath of workers exposed to crystalline silica dust by SPME-GC-MS. Journal of Research in Health Sciences, 16(3), 153-161.
Kataoka, H., & Saito, K. (2011). Recent advances in SPME techniques in biomedical analysis. Journal of Pharmaceutical and Biomedical Analysis, 54(5), 926-950. https://doi.org/10.1016/j.jpba.2010.12.010
Kędziora, K., & Wasiak, W. (2017). Extraction media used in needle trap devices-Progress in development and application. Journal of Chromatography a, 1505, 1-17. https://doi.org/10.1016/j.chroma.2017.05.030
Koziel, J. A., Odziemkowski, M., & Pawliszyn, J. (2001). Sampling and analysis of airborne particulate matter and aerosols using in-needle trap and SPME fiber devices. Analytical Chemistry, 73(1), 47-54.
Kumar, A., Malik, A. K., Tewary, D. K., & Singh, B. (2008). A review on development of solid phase microextraction fibers by sol-gel methods and their applications. Analytica Chimica Acta, 610(1), 1-14. https://doi.org/10.1016/j.aca.2008.01.028
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008). Environmental and bioanalytical applications of hollow fiber membrane liquid-phase microextraction: A review. Analytica Chimica Acta, 624(2), 253-268. https://doi.org/10.1016/j.aca.2008.06.050
Lee, J.-E., Lim, H.-H., & Shin, H.-S. (2019). Simultaneous determination of 15 BTEX hydroxyl biomarkers in urine by headspace solid-phase microextraction gas chromatography-mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis, 174, 115-122. https://doi.org/10.1016/j.jpba.2019.05.033
Li, G., & Row, K. H. (2018). Recent applications of molecularly imprinted polymers (MIPs) on micro-extraction techniques. Separation & Purification Reviews, 47(1), 1-18. https://doi.org/10.1080/15422119.2017.1315823
Manno, M., Sito, F., & Licciardi, L. (2014). Ethics in biomonitoring for occupational health. Toxicology Letters, 231(2), 111-121. https://doi.org/10.1016/j.toxlet.2014.10.004
Manno, M., Viau, C., Cocker, J., Colosio, C., Lowry, L., Mutti, A., … Wang, S. (2010). Biomonitoring for occupational health risk assessment (BOHRA). Toxicology Letters, 192, 3-16. https://doi.org/10.1016/j.toxlet.2009.05.001
Marchand, A., Aranda-Rodriguez, R., Tardif, R., Nong, A., & Haddad, S. (2015). Human inhalation exposures to toluene, ethylbenzene, and m-xylene and physiologically based pharmacokinetic modeling of exposure biomarkers in exhaled air, blood, and urine. Toxicological Sciences, 144(2), 414-424. https://doi.org/10.1093/toxsci/kfv009
Menezes, H. C., Amorim, L. C., & Cardeal, Z. L. (2009). Sampling of benzene in environmental and exhaled air by solid-phase microextraction and analysis by gas chromatography-mass spectrometry. Analytical and Bioanalytical Chemistry, 395(8), 2583-2589. https://doi.org/10.1007/s00216-009-3206-x
Moein, M. M., Abdel-Rehim, A., & Abdel-Rehim, M. (2015). Microextraction by packed sorbent (MEPS). TrAC Trends in Analytical Chemistry, 67, 34-44. https://doi.org/10.1016/j.trac.2014.12.003
Moein, M. M., El-Beqqali, A., Javanbakht, M., Karimi, M., Akbari-Adergani, B., & Abdel-Rehim, M. (2014). On-line detection of hippuric acid by microextraction with a molecularly-imprinted polysulfone membrane sorbent and liquid chromatography-tandem mass spectrometry. Journal of Chromatography a, 1372, 55-62. https://doi.org/10.1016/j.chroma.2014.10.061
Moein, M. M., Said, R., & Abdel-Rehim, M. (2015). Microextraction by packed sorbent. Bioanalysis, 7(17), 2155-2161. https://doi.org/10.4155/bio.15.154
Namera, A., & Saito, T. (2013). Recent advances in unique sample preparation techniques for bioanalysis. Bioanalysis, 5(8), 915-932. https://doi.org/10.4155/bio.13.52
NIOSH. (2003). NIOSH, hippuric and methyl hippuric acids in urine (NIOSH 8301). In NIOSH Manual of Analytical Methods (NMAM) (pp. 3-7). Diane Publishing.
Ocaña-González, J. A., Fernández-Torres, R., Bello-López, M. Á., & Ramos-Payán, M. (2016). New developments in microextraction techniques in bioanalysis. A review. Analytica chimica acta, 905, 8-23. https://doi.org/10.1016/j.aca.2015.10.041
O'Connell, E., & Hurley, F. (2009). A review of the strengths and weaknesses of quantitative methods used in health impact assessment. Public Health, 123(4), 306-310. https://doi.org/10.1016/j.puhe.2009.02.008
Ouyang, G., & Jiang, R. (2016). Solid phase microextraction: Recent developments and applications. Springer.
Pawliszyn, J. (2002). Sampling and sample preparation in field and laboratory (Vol. 37). Fundamentals and new directions in sample preparation. Elsevier.
Pirmohammadi, Z., Bahrami, A., Nematollahi, D., Alizadeh, S., Ghorbani Shahna, F., & Rahimpoor, R. (2020). Determination of urinary methylhippuric acids using MIL-53-NH 2 (Al) metal-organic framework in microextraction by packed sorbent followed by HPLC-UV analysis. Biomedical Chromatography, 34(1), e4725. https://doi.org/10.1002/bmc.4725
Poormohammadi, A., Bahrami, A., Farhadian, M., Shahna, F. G., & Ghiasvand, A. (2017). Development of Carbotrap B-packed needle trap device for determination of volatile organic compounds in air. Journal of Chromatography a, 1527, 33-42. https://doi.org/10.1016/j.chroma.2017.10.062
Qian, H.-L., Yang, C.-X., Wang, W.-L., Yang, C., & Yan, X.-P. (2018). Advances in covalent organic frameworks in separation science. Journal of Chromatography a, 1542, 1-18. https://doi.org/10.1016/j.chroma.2018.02.023
Qiao, F., Sun, H., Yan, H., & Row, K. H. (2006). Molecularly imprinted polymers for solid phase extraction. Chromatographia, 64(11-12), 625-634. https://doi.org/10.1365/s10337-006-0097-2
Rahimpoor, R., Bahrami, A., Nematollahi, D., Shahna, F. G., & Farhadian, M. (2019). Facile and sensitive determination of urinary mandelic acid by combination of metal organic frameworks with microextraction by packed sorbents. Journal of Chromatography B, 1114, 45-54.
Rezazadeh, M., Yamini, Y., & Seidi, S. (2014). Microextraction in urine samples for gas chromatography: A review. Bioanalysis, 6(19), 2663-2684. https://doi.org/10.4155/bio.14.215
Roszkowska, A., Miękus, N., & Bączek, T. (2019). Application of solid-phase microextraction in current biomedical research. Journal of Separation Science, 42(1), 285-302. https://doi.org/10.1002/jssc.201800785
Rumchev, K., Brown, H., & Spickett, J. (2007). Volatile organic compounds: Do they present a risk to our health? Reviews on Environmental Health, 22(1), 39-55. https://doi.org/10.1515/reveh.2007.22.1.39
Saedi, N., Bahrami, A., Ghorbani Shahna, F., Habibi Mohraz, M., Farhadian, M., & Alizadeh, S. (2020). A needle trap device packed with MIL-100 (Fe) metal organic frameworks for efficient headspace sampling and analysis of urinary BTEXs. Biomedical Chromatography, 34(4), e4800. https://doi.org/10.1002/bmc.4800
Sakhvidi, M. J. Z., Bahrami, A., Ghiasvand, A., Mahjub, H., & Tuduri, L. (2012). Field application of SPME as a novel tool for occupational exposure assessment with inhalational anesthetics. Environmental Monitoring and Assessment, 184(11), 6483-6490. https://doi.org/10.1007/s10661-011-2434-7
Semple, S. (2004). Dermal exposure to chemicals in the workplace: Just how important is skin absorption? Occupational and Environmental Medicine, 61(4), 376-382. https://doi.org/10.1136/oem.2003.010645
Shen, L., Xiang, P., Liang, S., Chen, W., Wang, M., Lu, S., & Wang, Z. (2018). Sources profiles of volatile organic compounds (VOCs) measured in a typical industrial process in Wuhan, Central China. Atmosphere, 9(8), 297. https://doi.org/10.3390/atmos9080297
Soleimani, E., Bahrami, A., Afkhami, A., & Shahna, F. G. (2017). Determination of urinary trans,trans-muconic acid using molecularly imprinted polymer in microextraction by packed sorbent followed by liquid chromatography with ultraviolet detection. Journal of Chromatography B, 1061, 65-71.
Soleimani, E., Bahrami, A., Afkhami, A., & Shahna, F. G. (2018). Selective determination of mandelic acid in urine using molecularly imprinted polymer in microextraction by packed sorbent. Archives of Toxicology, 92(1), 213-222. https://doi.org/10.1007/s00204-017-2057-z
Song, H. N., Kim, C. H., Lee, W. Y., & Cho, S. H. (2017). Simultaneous determination of volatile organic compounds with a wide range of polarities in urine by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry. Rapid Communications in Mass Spectrometry, 31(7), 613-622. https://doi.org/10.1002/rcm.7827
Suh J. H., Lee H. Y., Kim U., Eom H. Y., Kim J., Cho H.-D., Han S. B. (2015). Simultaneous determination of benzene, toluene, ethylbenzene, and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry. Journal of Separation Science, 38(24), 4276-4285. https://doi.org/10.1002/jssc.201500969
Tajik, L., Bahrami, A., Ghiasvand, A., & Shahna, F. G. (2017). Determination of BTEX in urine samples using cooling/heating-assisted headspace solid-phase microextraction. Chemical Papers, 71(10), 1829-1838. https://doi.org/10.1007/s11696-017-0176-x
Tian, Y., & Zhu, G. (2020). Porous aromatic frameworks (PAFs). Chemical Reviews, 120(16), 8934-8986. https://doi.org/10.1021/acs.chemrev.9b00687
Venson, R., Korb, A.-S., & Cooper, G. (2019). A review of the application of hollow-fiber liquid-phase microextraction in bioanalytical methods-A systematic approach with focus on forensic toxicology. Journal of Chromatography B, 1108, 32-53. https://doi.org/10.1016/j.jchromb.2019.01.006
Wang, Y., Rui, M., & Lu, G. (2018). Recent applications of metal-organic frameworks in sample pretreatment. Journal of Separation Science, 41(1), 180-194. https://doi.org/10.1002/jssc.201700401
WHO. (2006). Principles for evaluating health risks in children associated with exposure to chemicals. World Health Organization.
Wilbur, S., & Bosch, S. (2004). Interaction profile for benzene, toluene, ethylbenzene, and xylenes (BTEX). Agency for Toxic Substances & Disease Registry (ATSDR).
Yousefi, S. M., Shemirani, F., & Ghorbanian, S. A. (2018). Modification of a steel fiber with a graphene based bucky gel for headspace solid-phase microextraction of volatile aromatic hydrocarbons prior to their quantification by GC. Microchimica Acta, 185(11), 509. https://doi.org/10.1007/s00604-018-3017-x
Zeverdegani, S. K., Bahrami, A., Rismanchian, M., & Shahna, F. G. (2014). Analysis of xylene in aqueous media using needle-trap microextraction with a carbon nanotube sorbent. Journal of Separation Science, 37(14), 1850-1855. https://doi.org/10.1002/jssc.201400262
Zeverdegani, S. K., Bahrami, A., Shahna, F. G., Rismanchian, M., & Heidari, M. (2014). Determination of toluene by needle trap micro-extraction with carbon nanotube sol-gel and polydimethylsiloxane sorbents. Analytical Letters, 47(13), 2165-2172. https://doi.org/10.1080/00032719.2014.900782
Zhang, G., Zou, L., & Xu, H. (2015). Anodic alumina coating for extraction of volatile organic compounds in human exhaled breath vapor. Talanta, 132, 528-534. https://doi.org/10.1016/j.talanta.2014.09.035
Zhao, X., Wang, Y., Li, D. S., Bu, X., & Feng, P. (2018). Metal-organic frameworks for separation. Advanced Materials, 30(37), 1705189. https://doi.org/10.1002/adma.201705189
Zhou, H., Ye, Q., & Xu, J. (2017). Polyhedral oligomeric silsesquioxane-based hybrid materials and their applications. Materials Chemistry Frontiers, 1(2), 212-230. https://doi.org/10.1039/C6QM00062B

Auteurs

Mohammadreza Bahrami (M)

Department of Health, Safety and Environment, School of Environment, College of Engineering, University of Tehran, Kish, Iran.

Zahra Pirmohammadi (Z)

Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.

Abdulrahman Bahrami (A)

Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH