Validation of radiographic quality of simulation software - ImaSim.


Journal

Journal of X-ray science and technology
ISSN: 1095-9114
Titre abrégé: J Xray Sci Technol
Pays: Netherlands
ID NLM: 9000080

Informations de publication

Date de publication:
2021
Historique:
pubmed: 6 4 2021
medline: 29 10 2021
entrez: 5 4 2021
Statut: ppublish

Résumé

Virtual radiographic simulation has been found educationally effective for students to practice their clinical examinations remotely or online. A free available virtual simulator-ImaSim has received particular attention for radiographic science education because of its portability, free of charge and no constrain of location and physical facility. However, it lacks evidence to validate this virtual simulation software to faithfully reproduce radiographs comparable to that taken from a real X-ray machine to date. To evaluate image quality of the virtual radiographs produced by the ImaSim. Thus, the deployment of this radiographic simulation software for teaching and experimental studying of radiography can be justified. A real medical X-ray examination machine is employed to scan three standard QC phantoms to produce radiographs for comparing to the corresponding virtual radiographs generated by ImaSim software. The high and low range of radiographic contrast and comprehensive contrast-detail performance are considered to characterize the radiographic quality of the virtual simulation software. ImaSim software can generate radiographs with a contrast ranging from 30% to 0.8% and a spatial resolution as low as 0.6mm under the selected exposure setting condition. The characteristics of contrast and spatial resolution of virtual simulation generally agree with that of real medical X-ray examination machine. ImaSim software can be used to simulate a radiographic imaging process to generate radiographs with contrast and detail detectability comparable to those produced by a real X-ray imaging machine. Therefore, it can be adopted as a flexible educational tool for proof of concept and experimental design in radiography.

Sections du résumé

BACKGROUND
Virtual radiographic simulation has been found educationally effective for students to practice their clinical examinations remotely or online. A free available virtual simulator-ImaSim has received particular attention for radiographic science education because of its portability, free of charge and no constrain of location and physical facility. However, it lacks evidence to validate this virtual simulation software to faithfully reproduce radiographs comparable to that taken from a real X-ray machine to date.
OBJECTIVE
To evaluate image quality of the virtual radiographs produced by the ImaSim. Thus, the deployment of this radiographic simulation software for teaching and experimental studying of radiography can be justified.
METHODS
A real medical X-ray examination machine is employed to scan three standard QC phantoms to produce radiographs for comparing to the corresponding virtual radiographs generated by ImaSim software. The high and low range of radiographic contrast and comprehensive contrast-detail performance are considered to characterize the radiographic quality of the virtual simulation software.
RESULTS
ImaSim software can generate radiographs with a contrast ranging from 30% to 0.8% and a spatial resolution as low as 0.6mm under the selected exposure setting condition. The characteristics of contrast and spatial resolution of virtual simulation generally agree with that of real medical X-ray examination machine.
CONCLUSION
ImaSim software can be used to simulate a radiographic imaging process to generate radiographs with contrast and detail detectability comparable to those produced by a real X-ray imaging machine. Therefore, it can be adopted as a flexible educational tool for proof of concept and experimental design in radiography.

Identifiants

pubmed: 33814484
pii: XST210860
doi: 10.3233/XST-210860
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

453-462

Auteurs

Zhonghang Wu (Z)

Department of Scientific Research, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, China.
Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.
School of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.

Jieying Yu (J)

School of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.

Qianqing Wu (Q)

School of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.

Pengfei Hou (P)

School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China.

Jiuai Sun (J)

School of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH