Lateral tenodesis procedures increase lateral compartment pressures more than anterolateral ligament reconstruction, when performed in combination with ACL reconstruction: a pilot biomechanical study.
Anterior Cruciate Ligament Injuries
/ physiopathology
Anterior Cruciate Ligament Reconstruction
/ methods
Biomechanical Phenomena
Cadaver
Humans
Joint Instability
/ surgery
Knee Joint
/ physiopathology
Ligaments, Articular
/ physiopathology
Pilot Projects
Pressure
Range of Motion, Articular
Rotation
Tenodesis
/ methods
ACL / PCL
biomechanics
knee
repair / reconstruction
Journal
Journal of ISAKOS : joint disorders & orthopaedic sports medicine
ISSN: 2059-7762
Titre abrégé: J ISAKOS
Pays: England
ID NLM: 101680867
Informations de publication
Date de publication:
03 2021
03 2021
Historique:
accepted:
22
10
2020
entrez:
9
4
2021
pubmed:
10
4
2021
medline:
1
9
2021
Statut:
ppublish
Résumé
Given the common occurrence of residual laxity and re-injury post anterior cruciate ligament reconstruction (ACLR), additional anterolateral procedures are increasingly used in combination with an ACLR. Despite the perception that there is a risk of over-constraining the lateral tibiofemoral (LTF) compartment, potentially leading to osteoarthritis, assessment on their effect on intra-articular compartment pressures is still lacking. Our objective was therefore, through a pilot biomechanical study, to compare LTF contact pressures after the most commonly used anterolateral procedures. A controlled laboratory pilot study was performed using 4 fresh-frozen cadaveric whole lower limbs. Through 0° to 90° of flexion, LTF contact pressures were measured with a Tekscan sensor, located under the lateral meniscus. Knee kinematics were obtained in 3 conditions of rotation (NR: neutral, ER: external and IR: internal rotation) to record the position of the knees for each loading condition. A Motion Analysis system with a coordinate system based on CT scans 3D bone modelling was used. After an ACLR, defined as the reference baseline, 5 anterolateral procedures were compared: anterolateral ligament reconstruction (ALLR), modified Ellison, deep Lemaire, superficial Lemaire and modified MacIntosh procedures. The last 3 procedures were randomised. For each procedure, the graft was fixed in NR at 30° of flexion and with a tension of 20 N. Compared with isolated ACLR, addition of either ALLR or modified Ellison procedure did not increased the overall LTF contact pressure (all p>0.05) through the full range of flexion for the IR condition. Conversely, deep Lemaire, superficial Lemaire and modified MacIntosh procedure (all p<0.05) did increase the overall LTF contact pressure compared with ACLR in IR. No significant difference was observed in ER and NR conditions. This pilot study, comparing the main anterolateral procedures, revealed that addition of either ALLR or modified Ellison procedure did not change the overall contact pressure in the LTF compartment through 0° to 90° of knee flexion. In contrast, the deep and superficial Lemaire, and modified MacIntosh procedures significantly increased overall LTF contact pressures when the knee was internally rotated.
Identifiants
pubmed: 33832979
pii: jisakos-2019-000368
doi: 10.1136/jisakos-2019-000368
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
66-73Informations de copyright
© International Society of Arthroscopy, Knee Surgery and Orthopaedic Sports Medicine 2021. No commercial re-use. See rights and permissions. Published by BMJ.
Déclaration de conflit d'intérêts
Competing interests: None declared.