Comparison of four high-throughput, automated immunoassays for the detection of SARS-CoV-2 antibodies.
Adult
Aged
Aged, 80 and over
Antibodies, Viral
/ blood
COVID-19
/ diagnosis
COVID-19 Serological Testing
/ methods
Female
General Practice
Health Personnel
High-Throughput Screening Assays
/ methods
Hospitalization
Humans
Immunoassay
/ methods
Male
Middle Aged
Pandemics
SARS-CoV-2
/ immunology
Seroepidemiologic Studies
United Kingdom
/ epidemiology
Young Adult
COVID-19
SARS-CoV-2
immunoassay method comparison
quantitative antibody tests
Journal
Annals of clinical biochemistry
ISSN: 1758-1001
Titre abrégé: Ann Clin Biochem
Pays: England
ID NLM: 0324055
Informations de publication
Date de publication:
09 2021
09 2021
Historique:
pubmed:
25
4
2021
medline:
24
9
2021
entrez:
24
4
2021
Statut:
ppublish
Résumé
A number of immunoassays have been developed to measure antibodies specific to SARS-CoV-2. More data is required on their comparability, particularly among those with milder infections and in the general practice population. The aim of this study was to compare four high-throughput automated anti-SARS-CoV-2 assays using samples collected from hospitalized patients and healthcare workers with confirmed SARS-CoV-2 infection. In addition, we collected general practice samples to compare antibody results and determine seroprevalence. Samples were collected from 57 hospitalized patients and nine healthcare workers at 14 days and at 28 days following confirmed SARS-CoV-2 infection. Samples were also collected from 225 patients presenting to general practice. Four assays were used: Abbott Architect IgG, Beckman Coulter DxI 800 IgG, Roche Cobas e801 total antibody and Siemens Advia Centaur XPT total antibody. All four assays showed concordance at 14 days in 83.9% of hospitalized patients and in 66.7% of healthcare workers. All four assays showed concordance at 28 days in 88.4% of hospitalized patients and 77.8% of healthcare workers. The sensitivity to detect recent infection was higher for the IgG assays than the total assays. All four assays showed concordance of 95.1% in the general practice population. Seroprevalence ranged from 4.9 to 5.8% depending on the assay used. All four assays showed excellent comparability, but it may be possible to obtain a negative result for any of the anti-SARS-CoV-2 assays in patients with confirmed previous SARS-CoV-2 infection. An equivocal range would be useful for all anti-SARS-CoV-2 assays.
Sections du résumé
BACKGROUND
A number of immunoassays have been developed to measure antibodies specific to SARS-CoV-2. More data is required on their comparability, particularly among those with milder infections and in the general practice population. The aim of this study was to compare four high-throughput automated anti-SARS-CoV-2 assays using samples collected from hospitalized patients and healthcare workers with confirmed SARS-CoV-2 infection. In addition, we collected general practice samples to compare antibody results and determine seroprevalence.
METHODS
Samples were collected from 57 hospitalized patients and nine healthcare workers at 14 days and at 28 days following confirmed SARS-CoV-2 infection. Samples were also collected from 225 patients presenting to general practice. Four assays were used: Abbott Architect IgG, Beckman Coulter DxI 800 IgG, Roche Cobas e801 total antibody and Siemens Advia Centaur XPT total antibody.
RESULTS
All four assays showed concordance at 14 days in 83.9% of hospitalized patients and in 66.7% of healthcare workers. All four assays showed concordance at 28 days in 88.4% of hospitalized patients and 77.8% of healthcare workers. The sensitivity to detect recent infection was higher for the IgG assays than the total assays. All four assays showed concordance of 95.1% in the general practice population. Seroprevalence ranged from 4.9 to 5.8% depending on the assay used.
CONCLUSIONS
All four assays showed excellent comparability, but it may be possible to obtain a negative result for any of the anti-SARS-CoV-2 assays in patients with confirmed previous SARS-CoV-2 infection. An equivocal range would be useful for all anti-SARS-CoV-2 assays.
Identifiants
pubmed: 33892600
doi: 10.1177/00045632211015711
doi:
Substances chimiques
Antibodies, Viral
0
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM