Elastic Image Fusion Software to Coregister Preoperatively Planned Pedicle Screws With Intraoperative Computed Tomography Data for Image-Guided Spinal Surgery.

3D-NAV AIRO image-guided surgery intraoperative CT navigated spine surgery pedicle screw screw placement

Journal

International journal of spine surgery
ISSN: 2211-4599
Titre abrégé: Int J Spine Surg
Pays: Netherlands
ID NLM: 101579005

Informations de publication

Date de publication:
Apr 2021
Historique:
entrez: 26 4 2021
pubmed: 27 4 2021
medline: 27 4 2021
Statut: ppublish

Résumé

For complex spinal cases, especially when robotic guidance is used, preoperative planning of pedicle screws can be helpful. Transfer of these preoperatively planned pedicle screws to intraoperative 3-dimensional imaging is challenging because of changes in anatomic alignment between preoperative supine and intraoperative prone imaging, especially when multiple levels are involved. In the spine, where each individual vertebra is subject to independent movement from adjacent level, rigid image fusion is confined to a single vertebra and can display fusion inaccuracies on adjacent levels. A novel elastic fusion algorithm is introduced to overcome these disadvantages. This study aimed to investigate image registration accuracy of preoperatively planned pedicle screws with an elastic fusion algorithm vs. rigid fusion for intraoperative placement with image-guided surgery. A total of 12 patients, were selected depending on the availability of a preoperative spinal computed tomography (CT) and an intraoperative AIRO CT scan (BrainLAB AG, Munich, Germany) of the same spinal region. To verify accuracy differences between rigid fusion and elastic fusion 76 bilateral screw trajectories were virtually defined in the preoperative CT image, and they were transferred via either rigid fusion or elastic fusion to the intraoperative CT scan. Accuracy of the transferred screws in the rigid and elastic fusion group was determined by measuring pedicle breaches on the intraoperative CT. In the rigid fusion group 1.3% of screws showed a breach of less than 2 mm, 9.2% showed breaches between 2 and 4 mm, and 18.4% of the screws showed an error above 4 mm. The elastic fusion group showed no breaches and provided high accuracy between preoperative and intraoperative screw placement. Elastic fusion provides high registration accuracy and represents a considerable step towards efficiency and safety in CT-based image-guided surgery. 3.

Sections du résumé

BACKGROUND BACKGROUND
For complex spinal cases, especially when robotic guidance is used, preoperative planning of pedicle screws can be helpful. Transfer of these preoperatively planned pedicle screws to intraoperative 3-dimensional imaging is challenging because of changes in anatomic alignment between preoperative supine and intraoperative prone imaging, especially when multiple levels are involved. In the spine, where each individual vertebra is subject to independent movement from adjacent level, rigid image fusion is confined to a single vertebra and can display fusion inaccuracies on adjacent levels. A novel elastic fusion algorithm is introduced to overcome these disadvantages. This study aimed to investigate image registration accuracy of preoperatively planned pedicle screws with an elastic fusion algorithm vs. rigid fusion for intraoperative placement with image-guided surgery.
METHODS METHODS
A total of 12 patients, were selected depending on the availability of a preoperative spinal computed tomography (CT) and an intraoperative AIRO CT scan (BrainLAB AG, Munich, Germany) of the same spinal region. To verify accuracy differences between rigid fusion and elastic fusion 76 bilateral screw trajectories were virtually defined in the preoperative CT image, and they were transferred via either rigid fusion or elastic fusion to the intraoperative CT scan. Accuracy of the transferred screws in the rigid and elastic fusion group was determined by measuring pedicle breaches on the intraoperative CT.
RESULTS RESULTS
In the rigid fusion group 1.3% of screws showed a breach of less than 2 mm, 9.2% showed breaches between 2 and 4 mm, and 18.4% of the screws showed an error above 4 mm. The elastic fusion group showed no breaches and provided high accuracy between preoperative and intraoperative screw placement.
CONCLUSION CONCLUSIONS
Elastic fusion provides high registration accuracy and represents a considerable step towards efficiency and safety in CT-based image-guided surgery.
LEVEL OF EVIDENCE METHODS
3.

Identifiants

pubmed: 33900987
pii: 8039
doi: 10.14444/8039
pmc: PMC8059388
doi:

Types de publication

Journal Article

Langues

eng

Pagination

295-301

Informations de copyright

This manuscript is generously published free of charge by ISASS, the International Society for the Advancement of Spine Surgery. Copyright © 2021 ISASS.

Références

Int J Med Robot. 2019 Jun;15(3):e1991
pubmed: 30758130
J Neurosurg Spine. 2012 Aug;17(2):113-22
pubmed: 22724594
World Neurosurg. 2013 Jan;79(1):162-72
pubmed: 22469525
Eur Spine J. 2016 Mar;25(3):716-23
pubmed: 25702317
Spine (Phila Pa 1976). 2009 Dec 15;34(26):2919-26
pubmed: 20010400
J Spinal Disord Tech. 2015 Jun;28(5):E298-303
pubmed: 23511642
J Craniofac Surg. 2012 Jan;23(1):272-8
pubmed: 22337424
Clin Orthop Relat Res. 2010 Nov;468(11):2985-91
pubmed: 20635175
Eur Spine J. 2013 Jan;22(1):148-55
pubmed: 22987158
Neurol Med Chir (Tokyo). 2011;51(5):397-402
pubmed: 21613771
World Neurosurg. 2017 Apr;100:325-335
pubmed: 28104526
World J Orthop. 2014 Apr 18;5(2):112-23
pubmed: 24829874
Eur Spine J. 2012 Feb;21(2):247-55
pubmed: 21901328
World Neurosurg. 2018 Oct;118:e175-e184
pubmed: 30257292
Spine (Phila Pa 1976). 2007 Feb 1;32(3):E111-20
pubmed: 17268254
Spine (Phila Pa 1976). 1990 Jan;15(1):11-4
pubmed: 2326693
Phys Med Biol. 2015 Mar 7;60(5):2075-90
pubmed: 25674851
Eur Spine J. 2013 Mar;22(3):654-60
pubmed: 23001415
Neurosurg Focus. 2014 Mar;36(3):E7
pubmed: 24580008

Auteurs

Franziska A Schmidt (FA)

Weill Cornell Brain and Spine Center, Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York.

Mary Mullally (M)

BrainLAB AG, Munich, Germany.

Martin Lohmann (M)

BrainLAB AG, Munich, Germany.

Patrick Hiepe (P)

BrainLAB AG, Munich, Germany.

Sertac Kirnaz (S)

Weill Cornell Brain and Spine Center, Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York.

Swathi Chidambaram (S)

Weill Cornell Brain and Spine Center, Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York.

Christoph Wipplinger (C)

Weill Cornell Brain and Spine Center, Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York.

Roger Härtl (R)

Weill Cornell Brain and Spine Center, Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York.

Classifications MeSH