Spino Cranial Angle and Degenerative Cervical Spondylolisthesis.
CT scan
Degenerative cervical spondylolisthesis
Spino cranial angle
T1 slope
Journal
World neurosurgery
ISSN: 1878-8769
Titre abrégé: World Neurosurg
Pays: United States
ID NLM: 101528275
Informations de publication
Date de publication:
07 2021
07 2021
Historique:
received:
19
02
2021
revised:
15
04
2021
accepted:
16
04
2021
pubmed:
28
4
2021
medline:
10
9
2021
entrez:
27
4
2021
Statut:
ppublish
Résumé
The purpose of our study was to analyze and compare the spino cranial angle (SCA) in patients with degenerative cervical spondylolisthesis (DCS) and asymptomatic controls and to determine whether SCA could help diagnose DCS. We enrolled 50 patients diagnosed with DCS (4.3%) from among 1168 patients and the same number of asymptomatic participants as the control group by using cervical radiographs. Both groups underwent cervical radiographs and computed tomography at the same time. Various sagittal parameters were measured on computed tomography in a standardized supine position and compared with the asymptomatic control group. The Spearman correlation coefficient was applied to test the correlation among the sagittal parameters in the DCS group. Multivariate logistic regression analysis and receiver operating characteristic curve analysis were performed to determine whether SCA could help predict DCS. Fifty patients were enrolled in the DCS group, and 50 asymptomatic participants were included in the control group. The SCA was significantly lower for the DCS group than for the control group (76.84 ± 7.48 degrees vs. 82.47 ± 8.06 degrees, P < 0.001), and the T1 slope (T1s) was significantly greater for the DCS group than for the control group (27.29 ± 7.84 degrees vs. 22.28 ± 6.43 degrees, P = 0.001). Except for SCA and T1s, no other parameters showed significant differences. The SCA on the computed tomography scan was significantly correlated with the values of the T1s (r = -0.890, P < 0.001), cervical lordosis (r = -0.437, P = 0.002), C2-C7 sagittal vertical axis (r = 0.397, P = 0.004), and thoracic inlet angle (r = -0.565, P < 0.001). Multivariate logistic regression analysis and receiver operating characteristic curve analysis showed that both a lower SCA and a higher T1s could be risk factors for DCS, and an SCA of <79.1 degrees demonstrated significant diagnostic value for the detection of DCS. Patients in the DCS group had a lower SCA and a higher T1s. Both a lower SCA and a higher T1s could be risk factors for DCS, and an SCA of <79.1 degrees demonstrated significant diagnostic value for the detection of DCS.
Identifiants
pubmed: 33905906
pii: S1878-8750(21)00612-4
doi: 10.1016/j.wneu.2021.04.071
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e517-e522Informations de copyright
Copyright © 2021 Elsevier Inc. All rights reserved.