The Effect of Rim Preparation, Labral Augmentation, and Labral Reconstruction on the Suction Seal of the Hip.
Journal
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
ISSN: 1526-3231
Titre abrégé: Arthroscopy
Pays: United States
ID NLM: 8506498
Informations de publication
Date de publication:
02 2022
02 2022
Historique:
received:
18
06
2020
revised:
14
04
2021
accepted:
22
04
2021
pubmed:
9
5
2021
medline:
11
3
2022
entrez:
8
5
2021
Statut:
ppublish
Résumé
To evaluate the biomechanical properties of the labral suction seal in the native labrum and after rim preparation, labral augmentation, and labral reconstruction. Eight hemi-pelvises were dissected to the level of labrum and mounted for biomechanical testing. Each specimen was tested in axial distraction starting with the native labrum and then sequentially following rim preparation from 12 to 3 o'clock, labral augmentation, and segmental labral reconstruction using the iliotibial band allograft. In each condition, the specimens were compressed to 250 N and then distracted at 10 mm/s with force and displacement continuously recorded. Each test was repeated 3 times, and the mean peak force, displacement at peak force, and work were calculated. Data were reported as a percentage of the intact values to account for sex and size differences. Statistical testing was performed via a repeated-measures analysis of variance with a post hoc Tukey analysis. Peak loads occurred within 2.21 to 3.11 mm of displacement. The mean peak force, displacement at peak force, and work relative to the intact condition were the following: rim preparation (91.1% ± 8.5%, 94.4% ± 14.3%, 93.4% ± 23.5%, respectively), augmentation (66.1% ± 27.6%, 78.2% ± 16.3%, 55.7% ± 30.7%, respectively), and reconstruction (55.6% ± 25.7%, 64.7% ± 31.4%, 38.7% ± 27.2%, respectively). There was no significant difference in peak force following the rim preparation (P = .807), but peak force was significantly decreased after augmentation and reconstruction (P = .010 and P < .001, respectively). There was no significant difference in displacement at peak force following rim preparation or augmentation (P = .936 and P = .125, respectively), but displacement at peak force was significantly decreased after reconstruction (P = .005). The work from the suction seal was significantly less in both augmentation and reconstruction states compared to the intact labrum (P = .004 and P < .001, respectively) and rim preparation (P = .017 and P < .001, respectively). The results show that the suction seal is not significantly changed following rim preparation. Relative to the rim preparation, labral augmentation may re-create the labral suction seal better than labral reconstruction. This study provides a biomechanical basis for surgical decision making and clinical management of patients with labral tears of the hip.
Identifiants
pubmed: 33964388
pii: S0749-8063(21)00442-4
doi: 10.1016/j.arthro.2021.04.050
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
365-373Informations de copyright
Copyright © 2021 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.