Multiple phosphorylated protein selective analysis via fluorous derivatization and liquid chromatography-electrospray ionization-mass spectrometry analysis.
Fluorous derivatization
Liquid chromatography-mass spectrometry
Multiple phosphorylated peptide
Phosphorylated protein
β-Casein
Journal
Analytical biochemistry
ISSN: 1096-0309
Titre abrégé: Anal Biochem
Pays: United States
ID NLM: 0370535
Informations de publication
Date de publication:
01 09 2021
01 09 2021
Historique:
received:
16
03
2021
revised:
27
04
2021
accepted:
04
05
2021
pubmed:
10
5
2021
medline:
15
12
2021
entrez:
9
5
2021
Statut:
ppublish
Résumé
Post-translational modification of proteins is involved in protein function and higher-order structure. Among such modification, phosphorylation is an important intracellular signal transduction pathway. Many studies on phosphorylated protein analysis using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) have been developed. However, there are few reports on the analysis of highly phosphorylated proteins because of their handling difficulty. Hence, we developed an analytical method that converts multiple phosphate groups contained in the peptides into perfluoroalkyl groups for selective analysis using fluorous affinity. Here, tryptic digested β-casein fragment peptides [RELEELNVPGEIVE(pSer)L(pSer)(pSer)(pSer)EESITR and FQ(pSer)EEQQQTEDELQDK] were used as model phosphorylated peptides. 1H,1H,2H,2H-Perfluorooctanethiol (PFOT) and 2,2,2-trifluoroethanethiol (TFET) were used as derivatization reagents for mono-phosphorylated peptides and multi-phosphorylated peptides, respectively, to derivatize via β-elimination/Michael addition. The derivatives were analyzed by LC-ESI-MS. A fluorous LC column is typically used to selectively retain the fluorous-derivatized peptides, which are expected to be separated from contaminants and non-phosphorylated peptides. When this method was applied to β-casein, TFET- and PFOT-derivatized peptides were strongly retained in the fluorous LC column and clearly separated from non-phosphorylated peptides on the chromatogram. Therefore, the developed method enables quantification of mono- and multi-phosphorylated peptides and is suitable for application in proteomics.
Identifiants
pubmed: 33965426
pii: S0003-2697(21)00148-2
doi: 10.1016/j.ab.2021.114247
pii:
doi:
Substances chimiques
Caseins
0
Peptide Fragments
0
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
114247Informations de copyright
Copyright © 2021 Elsevier Inc. All rights reserved.