Assessment of effectiveness of optimum physical distancing phenomena for COVID-19.


Journal

Physics of fluids (Woodbury, N.Y. : 1994)
ISSN: 1070-6631
Titre abrégé: Phys Fluids (1994)
Pays: United States
ID NLM: 101286829

Informations de publication

Date de publication:
May 2021
Historique:
received: 03 02 2021
accepted: 10 04 2021
entrez: 27 5 2021
pubmed: 28 5 2021
medline: 28 5 2021
Statut: ppublish

Résumé

Currently, COVID-19 is a global pandemic that scientists and engineers around the world are aiming to understand further through rigorous testing and observation. This paper aims to provide safe distance recommendations among individuals and minimize the spread of COVID-19, as well as examine the efficacy of face coverings as a tool to slow the spread of respiratory droplets. These studies are conducted using computational fluid dynamics analyses, where the infected person breathes, coughs, and sneezes at various distances and environmental wind conditions and while wearing a face-covering (mask or face shield). In cases where there were no wind conditions, the breathing and coughing simulations display 1-2 m physical distancing to be effective. However, when sneezing was introduced, the physical distancing recommendation of 2 m was deemed not effective; instead, a distance of 2.8 m and greater was found to be more effective in reducing the exposure to respiratory droplets. The evaluation of environmental wind conditions necessitated an increase in physical distancing measures in all cases. The case where breathing was measured with a gentle breeze resulted in a physical distancing recommendation of 1.1 m, while coughing caused a change from the previous recommendation of 2 m to a distance of 4.5 m or greater. Sneezing in the presence of a gentle breeze was deemed to be the most impactful, with a recommendation for physical distancing of 5.8 m or more. It was determined that face coverings can potentially provide protection to an uninfected person in static air conditions. However, the uninfected person's protection can be compromised even in gentle wind conditions.

Identifiants

pubmed: 34040335
doi: 10.1063/5.0046429
pii: 5.0046429
pmc: PMC8142834
doi:

Types de publication

Journal Article

Langues

eng

Pagination

051903

Informations de copyright

© 2021 Author(s).

Références

J Hosp Infect. 2011 Mar;77(3):252-6
pubmed: 21236516
Phys Fluids (1994). 2020 Aug 1;32(8):083305
pubmed: 35002198
J Hosp Infect. 2020 Mar;104(3):336-343
pubmed: 31545991
Ann Occup Hyg. 2013 May;57(4):493-506
pubmed: 23243192
N Engl J Med. 2004 Apr 22;350(17):1731-9
pubmed: 15102999
JAMA. 2020 May 12;323(18):1837-1838
pubmed: 32215590
J Aerosol Sci. 2020 Sep;147:105585
pubmed: 32427227
Rend Lincei Sci Fis Nat. 2020;31(3):505-537
pubmed: 32837713
Build Environ. 2006 Sep;41(9):1214-1222
pubmed: 32287998
Int J Energy Res. 2020 Jun 25;44(8):6093-6097
pubmed: 34173427
Aerosol Sci Technol. 2020 Apr 03;0(0):1-4
pubmed: 32308568
Phys Fluids (1994). 2020 Aug 1;32(8):083302
pubmed: 32831537
J Fluid Mech. 2020 Sep 28;903:F1
pubmed: 34191877
Phys Fluids (1994). 2020 Jul 1;32(7):073309
pubmed: 32684746
Build Environ. 2018 Jan 15;128:68-76
pubmed: 32287977
N Engl J Med. 2020 Feb 20;382(8):760-762
pubmed: 31978944
BMJ. 2020 Aug 25;370:m3223
pubmed: 32843355
J Infect Dis. 2022 May 4;225(9):1561-1568
pubmed: 32301491
PLoS One. 2013;8(4):e59970
pubmed: 23560060
Saf Sci. 2020 Oct;130:104866
pubmed: 32834511
Int J Environ Res Public Health. 2020 Apr 23;17(8):
pubmed: 32340347
J Am Coll Emerg Physicians Open. 2020 Jun 11;1(4):578-591
pubmed: 32838373
Clin Infect Dis. 2020 May 21;70(70 Suppl 1):S1-S2
pubmed: 32435798

Auteurs

Branson Chea (B)

Faculty of Engineering and Applied Science, Ontario Tech University, 2000 Simcoe Street North, Oshawa, Ontario L1H 7K4, Canada.

Andre Bolt (A)

Faculty of Engineering and Applied Science, Ontario Tech University, 2000 Simcoe Street North, Oshawa, Ontario L1H 7K4, Canada.

Martin Agelin-Chaab (M)

Faculty of Engineering and Applied Science, Ontario Tech University, 2000 Simcoe Street North, Oshawa, Ontario L1H 7K4, Canada.

Ibrahim Dincer (I)

Faculty of Engineering and Applied Science, Ontario Tech University, 2000 Simcoe Street North, Oshawa, Ontario L1H 7K4, Canada.

Classifications MeSH