Biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents for percutaneous coronary intervention: a contemporary registry-based analysis.


Journal

Coronary artery disease
ISSN: 1473-5830
Titre abrégé: Coron Artery Dis
Pays: England
ID NLM: 9011445

Informations de publication

Date de publication:
01 03 2022
Historique:
pubmed: 3 6 2021
medline: 8 3 2022
entrez: 2 6 2021
Statut: ppublish

Résumé

We aimed to compare the long-term outcomes of patients undergoing percutaneous coronary intervention (PCI) with biodegradable polymer drug-eluting stents (BP-DES) versus durable polymer drug-eluting stents (DP-DES). Among 11 517 PCIs with second-generation DES performed in our institution between 2007 and 2019, we identified 8042 procedures performed using DP-DES and 3475 using BP-DES. The primary outcome was target lesion failure, the composite target lesion revascularization (TLR), target vessel myocardial infarction and death. Propensity score matching was used to create a well-balanced cohort. Mean follow-up was 4.8 years. Of the 3413 matched pairs, 21% were females, and the mean age was 66 years. At 1 year, the primary outcome occurred in 8.3% patients versus 7.1% (P = 0.07), and TLR rate was 3% versus 2% (P = 0.006) in patients with DP-DES and BP-DES respectively. Within 5 years, the primary outcome occurred in 23.1% versus 23.4% (P = 0.44), and the rate of TLR was 7.2% versus 6.5% (P = 0.07) in patients with DP-DES and BP-DES, respectively. Similar rates of the composite outcome were observed throughout the entire follow-up. Target lesion revascularization rates were lower in the BP-DES group at 1-year but equalized within 5 years.

Identifiants

pubmed: 34074911
doi: 10.1097/MCA.0000000000001066
pii: 00019501-202203000-00006
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

105-113

Informations de copyright

Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

Références

Nowbar AN, Gitto M, Howard JP, Francis DP, Al-Lamee R. Mortality from Ischemic Heart Disease. Circ Cardiovasc Qual Outcomes 2019; 12:e005375.
Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, et al.; ESC Scientific Document Group. 2018 ESC/EACTS guidelines on myocardial revascularization. Eur Heart J 2019; 40:87–165.
Heart. Biodegradable-polymer drug-eluting stents: back to the future? 2017. https://heart-bmj-com.beilinson-ez.medlcp.tau.ac.il/content/103/2/91 . [Accessed 27 November 2020].
Nakazawa G, Finn AV, Vorpahl M, Ladich ER, Kolodgie FD, Virmani R. Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents. J Am Coll Cardiol 2011; 57:390–398.
Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, et al. The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol 2011; 57:1314–1322.
Garg S, Serruys PW. Coronary stents: looking forward. J Am Coll Cardiol 2010; 56:S43–S78.
Stefanini GG, Kalesan B, Serruys PW, Heg D, Buszman P, Linke A, et al. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial. Lancet 2011; 378:1940–1948.
Yamaji K, Räber L, Zanchin T, Spitzer E, Zanchin C, Pilgrim T, et al. Ten-year clinical outcomes of first-generation drug-eluting stents: the Sirolimus-Eluting vs. Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) VERY LATE trial. Eur Heart J 2016; 37:3386–3395.
Adriaenssens T, Joner M, Godschalk TC, Malik N, Alfonso F, Xhepa E, et al.; Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Investigators. Optical coherence tomography findings in patients with coronary stent thrombosis: a report of the PRESTIGE Consortium (Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort). Circulation 2017; 136:1007–1021.
Otsuka F, Byrne RA, Yahagi K, Mori H, Ladich E, Fowler DR, et al. Neoatherosclerosis: overview of histopathologic findings and implications for intravascular imaging assessment. Eur Heart J 2015; 36:2147–2159.
Windecker S, Haude M, Neumann FJ, Stangl K, Witzenbichler B, Slagboom T, et al. Comparison of a novel biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: results of the randomized BIOFLOW-II trial. Circ Cardiovasc Interv 2015; 8:e001441.
Otsuka F, Cheng Q, Yahagi K, Acampado E, Sheehy A, Yazdani SK, et al. Acute thrombogenicity of a durable polymer everolimus-eluting stent relative to contemporary drug-eluting stents with biodegradable polymer coatings assessed ex vivo in a swine shunt model. JACC Cardiovasc Interv 2015; 8:1248–1260.
Serruys PW, Farooq V, Kalesan B, de Vries T, Buszman P, Linke A, et al. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial. JACC Cardiovasc Interv 2013; 6:777–789.
Zanchin C, Ueki Y, Zanchin T, Häner J, Otsuka T, Stortecky S, et al. Everolimus-eluting biodegradable polymer versus everolimus-eluting durable polymer stent for coronary revascularization in routine clinical practice. JACC Cardiovasc Interv 2019; 12:1665–1675.
Kandzari DE, Koolen JJ, Doros G, Garcia-Garcia HM, Bennett J, Roguin A, et al.; BIOFLOW V Investigators. Ultrathin bioresorbable-polymer sirolimus-eluting stents versus thin durable-polymer everolimus-eluting stents for coronary revascularization: 3-year outcomes from the Randomized BIOFLOW V Trial. JACC Cardiovasc Interv 2020; 13:1343–1353.
Monjur MR, Said CF, Bamford P, Parkinson M, Szirt R, Ford T. Ultrathin-strut biodegradable polymer versus durable polymer drug-eluting stents: a meta-analysis. Open Heart 2020; 7:e001394.
El-Hayek G, Bangalore S, Casso Dominguez A, Devireddy C, Jaber W, Kumar G, et al. Meta-analysis of randomized clinical trials comparing biodegradable polymer drug-eluting stent to second-generation durable polymer drug-eluting stents. JACC Cardiovasc Interv 2017; 10:462–473.
Lou Y, Yu Y, Xi Z, Gao Y, Liu W, Nie X. Five-year outcomes of biodegradable polymer drug-eluting stents versus second-generation durable polymer drug-eluting stents: a meta-analysis of randomized controlled trials. Cardiovasc Drugs Ther 2019; 33:557–566.
Iglesias JF, Muller O, Heg D, Roffi M, Kurz DJ, Moarof I, et al. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial. Lancet 2019; 394:1243–1253.
Choe JC, Cha KS, Lee JG, Kim J, Shin JY, Ahn J, et al.; Korea Acute Myocardial Infarction Registry-National Institutes of Health Investigators. Long-term outcomes of biodegradable versus second-generation durable polymer drug-eluting stent implantations for myocardial infarction. JACC Cardiovasc Interv 2020; 13:97–111.

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH