Factors influencing the removal torque of palatal implant used for orthodontic anchorage.


Journal

Progress in orthodontics
ISSN: 2196-1042
Titre abrégé: Prog Orthod
Pays: Germany
ID NLM: 100936353

Informations de publication

Date de publication:
07 Jun 2021
Historique:
received: 30 12 2020
accepted: 28 04 2021
entrez: 7 6 2021
pubmed: 8 6 2021
medline: 9 6 2021
Statut: epublish

Résumé

A non-invasive method has recently been introduced to remove osseo-integrated palatal implants by using the implantation ratchet which is designed to screw in or unscrew the implants. Although a proof of concept has been published, the torque involved to successfully explant have not been investigated so far. The aim of this study was to assess the removal torque required to explant osseo-integrated and orthodontically utilized palatal implants, and to identify potentially influencing variables. Thirty-one consecutive patients (15 females, 16 males; mean age 24.1 ±7.4 years) with fully osseo-integrated and previously orthodontically loaded palatal implants (Orthosystem®: diameter 4.1mm/length 4.2mm/sandblasted with large grits (SLA) surface) were randomly assigned to either clockwise or counter-clockwise non-invasive explantation. The respective explantation tool with an electric torque control was placed on the abutment connection of the implant and secured by an occlusal screw. The primary outcome studied was maximal removal torque (MRT) needed to detach the implant from its socket which was recorded individually together with other potentially influencing secondary outcomes (gender, age, orthodontic loading time, use of local anaesthetics). Student's t-test was used to contrast MRT difference for the gender, type of suprastructure, use of local anaesthetics, and rotational direction. Spearman correlations was used to investigate associations between MRT and patient's age or duration loading time. Average MRT (148.6 ± 63.2N/cm) using ratchet as a non-invasive removal method of palatal implant was considered safe. The triangular head fractured of palatal implant at a torque level of 300.1 Ncm. Significantly higher explantation were recorded for male patients compared to female patients (182.0 ± 63.0 Ncm vs 112.8 ± 40.8 Ncm; P=0.001). On the other side, the mean removal torque for palatal removal in clockwise direction was non-significantly different (158.3 ± 58.6 Ncm) compared to counter-clockwise direction (139.4 ± 67.9 Ncm). Neither patient's age (p=0.324) nor loading time (p=0.214) were significantly correlated with removal torque values. Pertinent literature on this subject is practically non-existent, as orthodontics is presumably the only discipline where implant removal represents a treatment success. Mean MRT for successful palatal implant removal was 148.6±63.2Ncm, but a large spectrum was observed (minimum 31.5Ncm, maximum 272.8Ncm). This obvious heterogeneity underlines the importance to investigate possible influencing factors. The safe and simple non-invasive method for palatal implant removal necessitates moderate, but not high torque MRTs, independently of the torque direction. The necessary MRT seems clearly influenced by gender, but less so by patient's age or loading time.

Sections du résumé

BACKGROUND BACKGROUND
A non-invasive method has recently been introduced to remove osseo-integrated palatal implants by using the implantation ratchet which is designed to screw in or unscrew the implants. Although a proof of concept has been published, the torque involved to successfully explant have not been investigated so far. The aim of this study was to assess the removal torque required to explant osseo-integrated and orthodontically utilized palatal implants, and to identify potentially influencing variables.
MATERIALS AND METHOD METHODS
Thirty-one consecutive patients (15 females, 16 males; mean age 24.1 ±7.4 years) with fully osseo-integrated and previously orthodontically loaded palatal implants (Orthosystem®: diameter 4.1mm/length 4.2mm/sandblasted with large grits (SLA) surface) were randomly assigned to either clockwise or counter-clockwise non-invasive explantation. The respective explantation tool with an electric torque control was placed on the abutment connection of the implant and secured by an occlusal screw. The primary outcome studied was maximal removal torque (MRT) needed to detach the implant from its socket which was recorded individually together with other potentially influencing secondary outcomes (gender, age, orthodontic loading time, use of local anaesthetics). Student's t-test was used to contrast MRT difference for the gender, type of suprastructure, use of local anaesthetics, and rotational direction. Spearman correlations was used to investigate associations between MRT and patient's age or duration loading time.
RESULTS RESULTS
Average MRT (148.6 ± 63.2N/cm) using ratchet as a non-invasive removal method of palatal implant was considered safe. The triangular head fractured of palatal implant at a torque level of 300.1 Ncm. Significantly higher explantation were recorded for male patients compared to female patients (182.0 ± 63.0 Ncm vs 112.8 ± 40.8 Ncm; P=0.001). On the other side, the mean removal torque for palatal removal in clockwise direction was non-significantly different (158.3 ± 58.6 Ncm) compared to counter-clockwise direction (139.4 ± 67.9 Ncm). Neither patient's age (p=0.324) nor loading time (p=0.214) were significantly correlated with removal torque values.
CONCLUSIONS CONCLUSIONS
Pertinent literature on this subject is practically non-existent, as orthodontics is presumably the only discipline where implant removal represents a treatment success. Mean MRT for successful palatal implant removal was 148.6±63.2Ncm, but a large spectrum was observed (minimum 31.5Ncm, maximum 272.8Ncm). This obvious heterogeneity underlines the importance to investigate possible influencing factors. The safe and simple non-invasive method for palatal implant removal necessitates moderate, but not high torque MRTs, independently of the torque direction. The necessary MRT seems clearly influenced by gender, but less so by patient's age or loading time.

Identifiants

pubmed: 34095981
doi: 10.1186/s40510-021-00359-3
pii: 10.1186/s40510-021-00359-3
pmc: PMC8180535
doi:

Substances chimiques

Dental Implants 0

Types de publication

Journal Article Randomized Controlled Trial

Langues

eng

Sous-ensembles de citation

IM

Pagination

16

Références

Clin Oral Implants Res. 2015 Dec;26(12):1503-5
pubmed: 25350869
J Orofac Orthop. 1996 Jun;57(3):142-53
pubmed: 8655109
Bone Miner. 1987 Apr;2(2):73-85
pubmed: 3333019
Int J Adult Orthodon Orthognath Surg. 1998;13(3):201-9
pubmed: 9835819
Int J Oral Maxillofac Implants. 2015 Jan-Feb;30(1):35-40
pubmed: 25506646
Clin Oral Implants Res. 2008 Jul;19(7):665-9
pubmed: 18492083
J Clin Orthod. 1997 Nov;31(11):763-7
pubmed: 9511584
Eur J Orthod. 2014 Feb;36(1):22-5
pubmed: 23525601
Eur J Orthod. 2007 Oct;29(5):443-8
pubmed: 17974534
Am J Orthod Dentofacial Orthop. 2015 Aug;148(2):274-82
pubmed: 26232836
Clin Oral Implants Res. 2014 Jun;25(6):653-8
pubmed: 23551587
Prog Orthod. 2018 Nov 5;19(1):43
pubmed: 30393829
Cochrane Database Syst Rev. 2013 Oct 23;(10):CD008375
pubmed: 24155018
JAMA. 2013 Nov 27;310(20):2191-4
pubmed: 24141714
Clin Oral Investig. 2020 Jan;24(1):47-60
pubmed: 31729576
Clin Oral Implants Res. 2009 Dec;20(12):1351-9
pubmed: 19793320
Clin Oral Implants Res. 2001 Apr;12(2):144-52
pubmed: 11251664
Am J Orthod Dentofacial Orthop. 2008 Jul;134(1):36-43
pubmed: 18617101
Int J Oral Maxillofac Implants. 2010 Jul-Aug;25(4):777-83
pubmed: 20657874
Int J Oral Maxillofac Implants. 1996 Mar-Apr;11(2):179-85
pubmed: 8666448
Am J Orthod Dentofacial Orthop. 1992 Jul;102(1):15-21
pubmed: 1626525
J Oral Implantol. 2016 Feb;42(1):3-11
pubmed: 25536339
Eur J Orthod. 2015 Dec;37(6):584-8
pubmed: 25667039
Int J Oral Maxillofac Implants. 2006 Mar-Apr;21(2):283-9
pubmed: 16634500

Auteurs

Marc Andreas Schätzle (MA)

Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland. marc.schaetzle@zzm.uzh.ch.

Monika Hersberger-Zurfluh (M)

Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland.

Raphael Patcas (R)

Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH