Nickel Hypersensitivity to Atrial Septal Occluders: Smoke Without Fire?


Journal

Clinical reviews in allergy & immunology
ISSN: 1559-0267
Titre abrégé: Clin Rev Allergy Immunol
Pays: United States
ID NLM: 9504368

Informations de publication

Date de publication:
Jun 2022
Historique:
accepted: 31 05 2021
pubmed: 16 6 2021
medline: 3 6 2022
entrez: 15 6 2021
Statut: ppublish

Résumé

Nickel is one of the most common contact allergens worldwide; it is used as the main component of the devices used for atrial septal defects (ASDs) and patent foramen ovale (PFO) closure. Developing nickel hypersensitivity after PFO/ASD occlusion is significantly rarer described in medical literature than typical nickel contact sensitization. The exact pathophysiological mechanism of this "device syndrome" remains unknown, and many question the real incidence or even the existence of this clinical entity. Nevertheless, it has been associated with a wide spectrum of symptoms, including chest pain, migraines, palpitation, and dyspnea. Skin patch tests are the first-line approach to diagnose nickel hypersensitivity. However, diagnostic criteria for the device syndrome have not been developed, and diagnosis in reported cases is established by a process of elimination. Management-drug therapy (corticosteroids, clopidogrel, etc.) or even surgical explantation in severe cases-of patients developing such clinical manifestations after percutaneous PFO/ASD occlusion is empirical. Undoubtedly, endocardiac device-related nickel hypersensitivity requires more focused research to discover the underlying mechanism as well as to develop reliable prognostic tests for detecting high-risk patients and preventing severe nickel hypersensitivity reactions.

Identifiants

pubmed: 34129170
doi: 10.1007/s12016-021-08867-0
pii: 10.1007/s12016-021-08867-0
doi:

Substances chimiques

Nickel 7OV03QG267

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

476-483

Informations de copyright

© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Références

Thyssen JP, Uter W, McFadden J et al (2011) The EU Nickel Directive revisited–future steps towards better protection against nickel allergy. Contact Dermatitis 64:121–125. https://doi.org/10.1111/j.1600-0536.2010.01852.x
doi: 10.1111/j.1600-0536.2010.01852.x pubmed: 21226718
Ringborg E, Lidén C, Julander A (2016) Nickel on the market: a baseline survey of articles in “prolonged contact” with skin. Contact Dermatitis 75:77–81. https://doi.org/10.1111/cod.12602
doi: 10.1111/cod.12602 pubmed: 27125984
Madhkour R, Wahl A, Praz F, Meier B (2019) Amplatzer patent foramen ovale occluder: safety and efficacy. Expert Rev Med Devices 16:173–182. https://doi.org/10.1080/17434440.2019.1581060
doi: 10.1080/17434440.2019.1581060 pubmed: 30741039
Ntaios G, Tzikas A, Vavouranakis E et al (2020) Expert consensus statement for the management of patients with embolic stroke of undetermined source and patent foramen ovale: a clinical guide by the working group for stroke of the Hellenic Society of Cardiology and the Hellenic Stroke Organization. Hellenic J. Cardiol
de Hemptinne Q, Horlick EM, Osten MD et al (2017) Initial clinical experience with the GORE(®) CARDIOFORM ASD occluder for transcatheter atrial septal defect closure. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 90:495–503. https://doi.org/10.1002/ccd.26907
doi: 10.1002/ccd.26907
Ahlström MG, Thyssen JP, Wennervaldt M et al (2019) Nickel allergy and allergic contact dermatitis: a clinical review of immunology, epidemiology, exposure, and treatment. Contact Dermatitis 81:227–241. https://doi.org/10.1111/cod.13327
doi: 10.1111/cod.13327 pubmed: 31140194
Ahlström MG, Thyssen JP, Menné T, Johansen JD (2017) Prevalence of nickel allergy in Europe following the EU Nickel Directive - a review. Contact Dermatitis 77:193–200. https://doi.org/10.1111/cod.12846
doi: 10.1111/cod.12846 pubmed: 28730624
Diepgen TL, Ofenloch RF, Bruze M et al (2016) Prevalence of contact allergy in the general population in different European regions. Br J Dermatol 174:319–329. https://doi.org/10.1111/bjd.14167
doi: 10.1111/bjd.14167 pubmed: 26370659
Lagrelius M, Wahlgren CF, Matura M et al (2016) High prevalence of contact allergy in adolescence: results from the population-based BAMSE birth cohort. Contact Dermatitis 74:44–51. https://doi.org/10.1111/cod.12492
doi: 10.1111/cod.12492 pubmed: 26538115
Reddy BT, Patel JB, Powell DL, Michaels AD (2009) Interatrial shunt closure devices in patients with nickel allergy. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 74:647–651. https://doi.org/10.1002/ccd.22155
doi: 10.1002/ccd.22155
Meier B (2009) Nickel allergy and device closure of the patent foramen ovale, now that we were told should we care? Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 74:652
doi: 10.1002/ccd.22242
Ricciardi L, Arena A, Arena E et al (2014) Systemic nickel allergy syndrome: epidemiological data from four Italian allergy units. Int J Immunopathol Pharmacol 27:131–136
doi: 10.1177/039463201402700118
Warshaw EM, Raju SI, Fowler JFJ et al (2012) Positive patch test reactions in older individuals: retrospective analysis from the North American Contact Dermatitis Group, 1994–2008. J Am Acad Dermatol 66:229–240. https://doi.org/10.1016/j.jaad.2010.12.022
doi: 10.1016/j.jaad.2010.12.022 pubmed: 21596455
Prakash AV, Davis MDP (2010) Contact dermatitis in older adults: a review of the literature. Am J Clin Dermatol 11:373–381. https://doi.org/10.2165/11319290-000000000-00000
doi: 10.2165/11319290-000000000-00000 pubmed: 20812765
Simonsen AB, Deleuran M, Johansen JD, Sommerlund M (2011) Contact allergy and allergic contact dermatitis in children - a review of current data. Contact Dermatitis 65:254–265. https://doi.org/10.1111/j.1600-0536.2011.01963.x
doi: 10.1111/j.1600-0536.2011.01963.x pubmed: 21851361
Thyssen JP, Menné T (2010) Metal allergy–a review on exposures, penetration, genetics, prevalence, and clinical implications. Chem Res Toxicol 23:309–318. https://doi.org/10.1021/tx9002726
doi: 10.1021/tx9002726 pubmed: 19831422
Hamann CR, Hamann D, Egeberg A et al (2017) Association between atopic dermatitis and contact sensitization: a systematic review and meta-analysis. J Am Acad Dermatol 77:70–78. https://doi.org/10.1016/j.jaad.2017.02.001
doi: 10.1016/j.jaad.2017.02.001 pubmed: 28392290
Tas B (2020) Demographic and clinical features and subsectoral differences in occupational contact allergens in clothing manufacturing workers. Am J Ind Med 63:1008–1016. https://doi.org/10.1002/ajim.23178
doi: 10.1002/ajim.23178 pubmed: 32914884
Symanzik C, John SM, Strunk M (2019) Nickel release from metal tools in the German hairdressing trade-a current analysis. Contact Dermatitis 80:382–385. https://doi.org/10.1111/cod.13251
doi: 10.1111/cod.13251 pubmed: 30805936
Lyons G, Roberts H, Palmer A et al (2013) Hairdressers presenting to an occupational dermatology clinic in Melbourne, Australia. Contact Dermatitis 68:300–306. https://doi.org/10.1111/cod.12016
doi: 10.1111/cod.12016 pubmed: 23586498
Gordon BM, Moore JW (2009) Nickel for your thoughts: Survey of the Congenital Cardiovascular Interventional Study Consortium (CCISC) for nickel allergy. J Invasive Cardiol 21:326–329
pubmed: 19571342
Verma SK, Tobis JM (2011) Explantation of patent foramen ovale closure devices: a multicenter survey. JACC Cardiovasc Interv 4:579–585. https://doi.org/10.1016/j.jcin.2011.01.009
doi: 10.1016/j.jcin.2011.01.009 pubmed: 21596333
Martin SF (2015) New concepts in cutaneous allergy. Contact Dermatitis 72:2–10. https://doi.org/10.1111/cod.12311
doi: 10.1111/cod.12311 pubmed: 25348820
Braga M, Quecchia C, Perotta C et al (2013) Systemic nickel allergy syndrome: nosologic framework and usefulness of diet regimen for diagnosis. Int J Immunopathol Pharmacol 26:707–716. https://doi.org/10.1177/039463201302600314
doi: 10.1177/039463201302600314 pubmed: 24067467
Darlenski R, Kazandjieva J, Pramatarov K (2012) The many faces of nickel allergy. Int J Dermatol 51:523–530. https://doi.org/10.1111/j.1365-4632.2011.05233.x
doi: 10.1111/j.1365-4632.2011.05233.x pubmed: 22515577
Rustemeyer T, von Blomberg BME, van Hoogstraten IMW et al (2004) Analysis of effector and regulatory immune reactivity to nickel. Clin Exp allergy J Br Soc Allergy Clin Immunol 34:1458–1466. https://doi.org/10.1111/j.1365-2222.2004.02045.x
doi: 10.1111/j.1365-2222.2004.02045.x
Han JW, Shimada K, Ma-Krupa W et al (2008) Vessel wall-embedded dendritic cells induce T-cell autoreactivity and initiate vascular inflammation. Circ Res 102:546–553. https://doi.org/10.1161/CIRCRESAHA.107.161653
doi: 10.1161/CIRCRESAHA.107.161653 pubmed: 18202318
Verma DR, Khan MF, Tandar A et al (2015) Nickel elution properties of contemporary interatrial shunt closure devices. J Invasive Cardiol 27:99–104
pubmed: 25661761
Jalal Z, Boudjemline Y, Iriart X et al (2020) Comparison of two percutaneous atrial septal defect occluders for device healing and nickel release in a chronic porcine model. J Interv Cardiol 2020:8413831. https://doi.org/10.1155/2020/8413831
doi: 10.1155/2020/8413831 pubmed: 32665769 pmcid: 7327569
Ries MW, Kampmann C, Rupprecht HJ et al (2003) Nickel release after implantation of the amplatzer occluder. Am Heart J 145:737–741. https://doi.org/10.1067/mhj.2003.7
doi: 10.1067/mhj.2003.7 pubmed: 12679773
Narayana G, Ramagopal G, Duggal B, Bansal NO (2018) Study of nickel levels in patients with atrial septal defect undergoing amplatzer device closure. Heart Views 19:85–87. https://doi.org/10.4103/HEARTVIEWS.HEARTVIEWS_76_17
doi: 10.4103/HEARTVIEWS.HEARTVIEWS_76_17 pubmed: 31007856 pmcid: 6448472
Elkiran O, Karakurt C, Kocak G, Taskapan C (2019) Serum nickel and titanium levels after transcatheter closure of atrial septal defects with amplatzer septal occluder. Cardiol Res Pract 2019:7891746. https://doi.org/10.1155/2019/7891746
doi: 10.1155/2019/7891746 pubmed: 30719342 pmcid: 6334312
Resor CD, Goldminz AM, Shekar P et al (2020) Systemic allergic contact dermatitis due to a GORE CARDIOFORM septal occluder device: a case report and literature review. JACC Case Reports 2:1867–1871. https://doi.org/10.1016/j.jaccas.2020.05.091
Prestipino F, Pragliola C, Lusini M, Chello M (2014) Nickel allergy induced systemic reaction to an intracardiac amplatzer device. J Card Surg 29:349–350. https://doi.org/10.1111/jocs.12331
doi: 10.1111/jocs.12331 pubmed: 24762035
Almpanis GC, Tsigkas GG, Koutsojannis C et al (2010) Nickel allergy, Kounis syndrome and intracardiac metal devices. Int J Cardiol 145:364–365
doi: 10.1016/j.ijcard.2010.02.038
Calnan CD (1956) Nickel dermatitis. Br J Dermatol 68:229–236. https://doi.org/10.1111/j.1365-2133.1956.tb12808.x
doi: 10.1111/j.1365-2133.1956.tb12808.x pubmed: 13342338
Rigatelli G, Cardaioli P, Giordan M et al (2007) Nickel allergy in interatrial shunt device-based closure patients. Congenit Heart Dis 2:416–420. https://doi.org/10.1111/j.1747-0803.2007.00134.x
doi: 10.1111/j.1747-0803.2007.00134.x pubmed: 18377434
Pristipino C, Germonpré P, Toni D et al (2021) European position paper on the management of patients with patent foramen ovale. Part II - decompression sickness, migraine, arterial deoxygenation syndromes and select high-risk clinical conditions. EuroIntervention J Eur Collab with Work Gr Interv Cardiol Eur Soc Cardiol. https://doi.org/10.4244/EIJ-D-20-00785
Rodés-Cabau J, Horlick E, Ibrahim R et al (2015) Effect of clopidogrel and aspirin vs aspirin alone on migraine headaches after transcatheter atrial septal defect closure: the CANOA Randomized clinical trial. JAMA 314:2147–2154. https://doi.org/10.1001/jama.2015.13919
doi: 10.1001/jama.2015.13919 pubmed: 26551304
Safouris A, Kargiotis O, Psychogios K et al (2020) A narrative and critical review of randomized-controlled clinical trials on patent foramen ovale closure for reducing the risk of stroke recurrence. Front Neurol 11:434. https://doi.org/10.3389/fneur.2020.00434
doi: 10.3389/fneur.2020.00434 pubmed: 32655469 pmcid: 7326015
Aggeli C, Verveniotis A, Andrikopoulou E et al (2018) Echocardiographic features of PFOs and paradoxical embolism: a complicated puzzle. Int J Cardiovasc Imaging 34:1849–1861. https://doi.org/10.1007/s10554-018-1406-1
doi: 10.1007/s10554-018-1406-1 pubmed: 29956022
Apostolos A, Drakopoulou M, Toutouzas K (2020) New migraines after atrial septal defect occlusion. Is the nickel hypersensitivity the start of everything? Med Hypotheses 110442
Slavin L, Tobis JM, Rangarajan K et al (2007) Five-year experience with percutaneous closure of patent foramen ovale. Am J Cardiol 99:1316–1320. https://doi.org/10.1016/j.amjcard.2006.12.054
doi: 10.1016/j.amjcard.2006.12.054 pubmed: 17478165
Jain M, Singh S, Cadeiras M (2013) A case of nitinol allergy causing pericardial tamponade. J Invasive Cardiol 25:E180–E182
pubmed: 23995727
Lai DW, Saver JL, Araujo JA et al (2005) Pericarditis associated with nickel hypersensitivity to the Amplatzer occluder device: a case report. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv 66:424–426. https://doi.org/10.1002/ccd.20497
doi: 10.1002/ccd.20497
Khodaverdian RA, Jones KW (2009) Metal allergy to Amplatzer occluder device presented as severe bronchospasm. Ann Thorac Surg 88:2021–2022. https://doi.org/10.1016/j.athoracsur.2009.05.044
doi: 10.1016/j.athoracsur.2009.05.044 pubmed: 19932286
Menné T, Calvin G (1993) Concentration threshold of non-occluded nickel exposure in nickel-sensitive individuals and controls with and without surfactant. Contact Dermatitis 29:180–184. https://doi.org/10.1111/j.1600-0536.1993.tb03533.x
doi: 10.1111/j.1600-0536.1993.tb03533.x pubmed: 8281779
Johansen JD, Aalto-Korte K, Agner T et al (2015) European Society of Contact Dermatitis guideline for diagnostic patch testing - recommendations on best practice. Contact Dermatitis 73:195–221. https://doi.org/10.1111/cod.12432
doi: 10.1111/cod.12432 pubmed: 26179009
Warshaw EM, Aschenbeck KA, DeKoven JG et al (2018) Epidemiology of pediatric nickel sensitivity: retrospective review of North American Contact Dermatitis Group (NACDG) data 1994–2014. J Am Acad Dermatol 79:664–671. https://doi.org/10.1016/j.jaad.2018.02.071
doi: 10.1016/j.jaad.2018.02.071 pubmed: 29665973
Popple A, Williams J, Maxwell G et al (2016) The lymphocyte transformation test in allergic contact dermatitis: New opportunities. J Immunotoxicol 13:84–91. https://doi.org/10.3109/1547691X.2015.1008656
doi: 10.3109/1547691X.2015.1008656 pubmed: 25655136
Christensen OB, Wall LM (1987) Open, closed and intradermal testing in nickel allergy. Contact Dermatitis 16:21–26. https://doi.org/10.1111/j.1600-0536.1987.tb02610.x
doi: 10.1111/j.1600-0536.1987.tb02610.x pubmed: 3816203
Singh HR, Turner DR, Forbes TJ (2004) Nickel allergy and the amplatzer septal occluder. J Invasive Cardiol 16:681–682
pubmed: 15550748
Arı H, Arı S, Tütüncü A et al (2017) Transcatheter closure of atrial septal defect with atrial septal occluder in a patient with nickel allergy. Turk Kardiyol Dern Ars 45:355–357. https://doi.org/10.5543/tkda.2016.23552
doi: 10.5543/tkda.2016.23552 pubmed: 28595206
Kim HJ, Shin JU, Lee J et al (2015) Positive reactions to nickel on a patch test do not predict clinical outcome of nickel alloy-based atrial septal defect occluder implantation. Dermatology 230:184–188. https://doi.org/10.1159/000371511
doi: 10.1159/000371511 pubmed: 25634825
Drakopoulou M, Soulaidopoulos S, Stathogiannis K et al (2020) Antiplatelet and antithrombotic therapy after patent foramen oval and atrial septal defect closure. Curr Pharm Des 26:2769–2779. https://doi.org/10.2174/1385272824999200427083838
doi: 10.2174/1385272824999200427083838 pubmed: 32338207
Fukahara K, Minami K, Reiss N et al (2003) Systemic allergic reaction to the percutaneous patent foramen ovale occluder. J Thorac Cardiovasc Surg 125:213–214. https://doi.org/10.1067/mtc.2003.125
doi: 10.1067/mtc.2003.125 pubmed: 12539013
Dasika UK, Kanter KR, Vincent R (2003) Nickel allergy to the percutaneous patent foramen ovale occluder and subsequent systemic nickel allergy. J Thorac Cardiovasc Surg 126:2112
doi: 10.1016/j.jtcvs.2003.06.005
Kim KH, Park JC, Yoon NS et al (2008) A case of allergic contact dermatitis following transcatheter closure of patent ductus arteriosus using Amplatzer ductal occluder. Int J Cardiol 127:e98–e99
doi: 10.1016/j.ijcard.2007.04.090
Rabkin DG, Whitehead KJ, Michaels AD et al (2009) Unusual presentation of nickel allergy requiring explantation of an Amplatzer atrial septal occluder device. Clin Cardiol 32:E55–E57. https://doi.org/10.1002/clc.20427
doi: 10.1002/clc.20427 pubmed: 19455702 pmcid: 6653388
Belohlavek J, Belohlavkova S, Hlubocky J et al (2013) Severe allergic dermatitis after closure of foramen ovale with Amplatzer occluder. Ann Thorac Surg 96:e57–e59. https://doi.org/10.1016/j.athoracsur.2013.01.079
doi: 10.1016/j.athoracsur.2013.01.079 pubmed: 23992730
Dickison P, Harris V, Smith SD (2018) Nickel hypersensitivity following closure of atrial septal defect: a case report and review of the literature. Australas J Dermatol 59:220–222. https://doi.org/10.1111/ajd.12787
doi: 10.1111/ajd.12787 pubmed: 29380348
Fernandes P, Sharma SR, Magee A et al (2019) Severe migraine associated with nickel allergy requiring surgical removal of atrial septal device. Ann Thorac Surg 108:e183–e184. https://doi.org/10.1016/j.athoracsur.2019.01.034
doi: 10.1016/j.athoracsur.2019.01.034 pubmed: 30794784

Auteurs

Anastasios Apostolos (A)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.

Maria Drakopoulou (M)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.

Stamatios Gregoriou (S)

First Department of Dermatology-Venereology, Medical School, National and Kapodistrian University of Athens, Andreas Suggros Hospital, Athens, Greece.

Andreas Synetos (A)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.

George Trantalis (G)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.

Georgios Tsivgoulis (G)

Second Department of Neurology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece.

Spyridon Deftereos (S)

Second Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece.

Konstantinos Tsioufis (K)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.

Konstantinos Toutouzas (K)

First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece. ktoutouz@gmail.com.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH