Comparison of the Chemiluminescence Immunoassay LIAISON® with the Radioimmunoassay for Aldosterone and Renin Measurement.

Aldosterone Chemiluminescenceassay Immunoradiometric assay Radioimmunoassay Renin

Journal

Prague medical report
ISSN: 1214-6994
Titre abrégé: Prague Med Rep
Pays: Czech Republic
ID NLM: 101227436

Informations de publication

Date de publication:
2021
Historique:
entrez: 17 6 2021
pubmed: 18 6 2021
medline: 22 6 2021
Statut: ppublish

Résumé

Determination of renin plasma levels is useful in the diagnosis of hypertension and in the therapeutic follow-up of hypertensive patients. Plasmatic concentration of renin decreases in patients with hypertension due to a primary hyperaldosteronism, contrary to renovascular hypertension where concentrations of renin and aldosterone are both elevated. Blood samples (serum, EDTA plasma) were analysed using two different chemiluminiscent methods CLIA LIAISON® and radioimmunoassay for aldosterone (IMMUNOTECH Beckman Coulter) and renin (Cisbio Bioassay) measurements were compared. We used both methods to ascertain the correlation between serum vs. EDTA plasma levels of aldosterone (RIA, CLIA) and renin (IRMA, CLIA) and to compare aldosterone to renin ratios for CLIA and for radioimmunoassay: serum aldosterone to plasma renin and plasma aldosterone to plasma renin. We compared serum aldosterone CLIA vs. RIA (rP=0.933, P<0.001) and plasma renin determined using CLIA vs. IRMA (rP=0.965, P=0.062). Furthermore, we used both methods to establish the correlation between the serum vs. plasma levels of aldosterone: RIA (rP=0.980, P<0.001); CLIA (rP=0.994, P=0.353) and serum vs. plasma levels of renin: IRMA (rP=0.948, P<0.001); CLIA (rP=0.921, P=0.011). Aldosterone (serum, plasma) to plasmatic renin ratios for CLIA (rP=0.999, P=0.286) and for radioimmunoassay (rP=0.992, P=0.025). Our data demonstrate that renin and aldosterone concentrations obtained using CLIA correlate with renin and aldosterone concentrations using radioimmunoassay methods. Correlation coefficients of pair results ranged from 0.921 to 0.994. Aldosterone (serum, EDTA plasma) to plasmatic renin ratios are comparable and any of them can be used with no significant differences found.

Identifiants

pubmed: 34137684
doi: 10.14712/23362936.2021.9
pii: pmr_2021122020080
doi:

Substances chimiques

Aldosterone 4964P6T9RB
Renin EC 3.4.23.15

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

80-95

Auteurs

Jana Uhrová (J)

Institute of Medical Biochemistry and Laboratory Diagnostics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. jana.uhrova@vfn.cz.

Hana Benáková (H)

Institute of Medical Biochemistry and Laboratory Diagnostics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.

Zdislava Vaníčková (Z)

Institute of Medical Biochemistry and Laboratory Diagnostics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.

Tomáš Zima (T)

Institute of Medical Biochemistry and Laboratory Diagnostics, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH