Comparison of cutaneous facial temperature using infrared thermography to standard temperature measurement in the critical care setting.
Fever screening
ICU
Infrared thermography
Temperature monitoring
Thermal cameras
Journal
Journal of clinical monitoring and computing
ISSN: 1573-2614
Titre abrégé: J Clin Monit Comput
Pays: Netherlands
ID NLM: 9806357
Informations de publication
Date de publication:
08 2022
08 2022
Historique:
received:
02
04
2021
accepted:
12
06
2021
pubmed:
18
6
2021
medline:
22
7
2022
entrez:
17
6
2021
Statut:
ppublish
Résumé
To assess the accuracy and precision of infrared cameras compared to traditional measures of temperature measurement in a temperature, humidity, and distance controlled intensive care unit (ICU) population. This was a prospective, observational methods comparison study in a single centre ICU in Metropolitan Melbourne, Australia. A convenience sample of 39 patients admitted to a single room equipped with two ceiling mounted thermal imaging cameras was assessed, comparing measured cutaneous facial temperature via thermal camera to clinical temperature standards. Uncorrected correlation of camera measurement to clinical standard in all cases was poor, with the maximum reported correlation 0.24 (Wide-angle Lens to Bladder temperature). Using the wide-angle lens, mean differences were - 11.1 °C (LoA - 14.68 to - 7.51), - 11.1 °C ( - 14.3 to - 7.9), and - 11.2 °C ( - 15.23 to - 7.19) for axillary, bladder, and oral comparisons respectively (Fig. 1a). With respect to the narrow-angle lens compared to the axillary, bladder and oral temperatures, mean differences were - 7.6 °C ( - 11.2 to - 4.0), - 7.5 °C ( - 12.1 to - 2.9), and - 7.9 °C ( - 11.6 to - 4.2) respectively. AUCs for the wide-angle lens and narrow-angle lens ranged from 0.53 to 0.70 and 0.59 to 0.79 respectively, with axillary temperature demonstrating the greatest values. Infrared thermography is a poor predictor of patient temperature as measured by existing clinical standards. It has a moderate ability to discriminate fever. It is unclear if this would be sensitive enough for infection screening purposes. Fig. 1 Bland-Altman plots for temperatures measured using clinical standards to infrared camera. a Wide-angle camera versus bladder temperature. b Narrow-angle camera versus bladder temperature.
Identifiants
pubmed: 34138396
doi: 10.1007/s10877-021-00731-y
pii: 10.1007/s10877-021-00731-y
pmc: PMC8210498
doi:
Types de publication
Journal Article
Observational Study
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1029-1036Informations de copyright
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.
Références
Chiu WT, et al. Infrared thermography to mass-screen suspected SARS patients with fever. Asia Pac J Public Health. 2005;17(1):26–8.
doi: 10.1177/101053950501700107
Aloweni FAB, et al. Evaluation of infrared technology to detect category I and suspected deep tissue injury in hospitalised patients. J Wound Care. 2019;28(Sup12):S9-s16.
doi: 10.12968/jowc.2019.28.Sup12.S9
Kirimtat A, et al. FLIR vs SEEK thermal cameras in biomedicine: comparative diagnosis through infrared thermography. BMC Bioinformatics. 2020;21(Suppl 2):88.
doi: 10.1186/s12859-020-3355-7
Sierra Olympic Technologies, Vayu HD 1920X1200 Camera. 2020. https://sierraolympic.com/wp-content/uploads/2020/06/2020_VayuHD_Sell-Sheet_FINAL.pdf . Accessed 18 May 2021.
Sun G, et al. Applications of infrared thermography for noncontact and noninvasive mass screening of febrile international travelers at airport quarantine stations. In: Application of Infrared to Biomedical Sciences. Singapore: Springer; 2017. p. 347–58.
doi: 10.1007/978-981-10-3147-2_19
Tay MR, et al. Comparison of infrared thermal detection systems for mass fever screening in a tropical healthcare setting. Public Health. 2015;129(11):1471–8.
doi: 10.1016/j.puhe.2015.07.023
Priest PC, et al. Thermal image scanning for influenza border screening: results of an airport screening study. PLoS ONE. 2011;6(1):e14490.
doi: 10.1371/journal.pone.0014490
Nguyen AV, et al. Comparison of 3 infrared thermal detection systems and self-report for mass fever screening. Emerg Infect Dis. 2010;16(11):1710–7.
doi: 10.3201/eid1611.100703
Adams, S., Kouzani, A., Bucknall, T. Are thermal cameras a magic bullet for COVID-19 fever detection? There’s not enough evidence to know. 2020. https://theconversation.com/are-thermal-cameras-a-magic-bullet-for-covid-19-fever-detection-theres-not-enough-evidence-to-know-139377 . Accessed 16 Oct 2020.
Thomas, R., Laing, H. Thermal cameras aren’t perfect, but they can help control the coronavirus pandemic. 2020. https://theconversation.com/thermal-cameras-arent-perfect-but-they-can-help-control-the-coronavirus-pandemic-141701 . Accessed 16 Oct 2020.
Tabata S, et al. Clinical characteristics of COVID-19 in 104 people with SARS-CoV-2 infection on the <em>diamond princess</em> cruise ship: a retrospective analysis. Lancet Infect Dis. 2020;20(9):1043–50.
doi: 10.1016/S1473-3099(20)30482-5
Swann OV, et al. Clinical characteristics of children and young people admitted to hospital with covid-19 in United Kingdom: prospective multicentre observational cohort study. BMJ. 2020;370:m3249.
doi: 10.1136/bmj.m3249
Zhu J, et al. Clinical characteristics of 3062 COVID-19 patients: a meta-analysis. J Med Virol. 2020;92(10):1902–14.
doi: 10.1002/jmv.25884
Chen J, et al. Clinical progression of patients with COVID-19 in Shanghai, China. J Infect. 2020;80(5):e1–6.
doi: 10.1016/j.jinf.2020.03.004
Huda, A.S.N., S. Taib, and D. Ishak. Necessity of Quantitative Based Thermographic Inspection of Electrical Equipments. 2012.
Ribeiro-Gomes K, et al. Uncooled thermal camera calibration and optimization of the photogrammetry process for UAV applications in agriculture. Sensors. 2017;17(10):2173.
doi: 10.3390/s17102173
Nugent PW, Shaw JA, Pust NJ. Correcting for focal-plane-array temperature dependence in microbolometer infrared cameras lacking thermal stabilization. Opt Eng. 2013;52(6):061304.
doi: 10.1117/1.OE.52.6.061304
Mesas-Carrascosa FJ, Pérez-Porras F, de MeroñoLarriva JE, MenaFrau C, Agüera-Vega F, Carvajal-Ramírez F, Martínez-Carricondo P, García-Ferrer A. Drift correction of lightweight microbolometer thermal sensors on-board unmanned aerial vehicles. Remote Sens. 2018;10:615.
doi: 10.3390/rs10040615
Chan LS, et al. Utility of infrared thermography for screening febrile subjects. Hong Kong Med J. 2013;19(2):109–15.
pubmed: 23535669
Moran JL, et al. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med. 2007;35(1):155–64.
doi: 10.1097/01.CCM.0000250318.31453.CB
Dell’Isola GB, et al. Noncontact body temperature measurement: uncertainty evaluation and screening decision rule to prevent the spread of COVID-19. Sensors. 2021;21(2):346.
doi: 10.3390/s21020346
Cho KS, Yoon J. Fever screening and detection of febrile arrivals at an international airport in Korea: association among self-reported fever, infrared thermal camera scanning, and tympanic temperature. Epidemiol Health. 2014;36:e2014004.
doi: 10.4178/epih/e2014004
Villa E, Arteaga-Marrero N, Ruiz-Alzola J. Performance assessment of low-cost thermal cameras for medical applications. Sensors. 2020;20(5):1321.
doi: 10.3390/s20051321
Niven DJ, Laupland KB. Pyrexia: aetiology in the ICU. Crit Care. 2016;20(1):247.
doi: 10.1186/s13054-016-1406-2
ASTM E1965-98. Standard specification for infrared thermometers for intermittent determination of patient temperature. West Conshohocken: ASTM International; 2016.
US Food and Drug Administration. Enforcement policy for telethermographic systems during the coronavirus disease 2019 (COVID-19) public health emergency. Silver Spring: CDRH and OPEQ; 2020.
Faye E, Dangles O, Pincebourde S. Distance makes the difference in thermography for ecological studies. J Therm Biol. 2016;56:1–9.
doi: 10.1016/j.jtherbio.2015.11.011
Edling L, et al. Forehead or axillary temperature measurement is not reliable. Methods and thermometers compared with rectal temperature measurement as a reference. Lakartidningen. 2010;107(46):2888–90.
pubmed: 21197785
Williams EM, Heusch AI, McCarthy PW. Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry. Physiol Meas. 2008;29(3):341–8.
doi: 10.1088/0967-3334/29/3/005
Khan S, et al. Comparative accuracy testing of non-contact infrared thermometers and temporal artery thermometers in an adult hospital setting. Am J Infect Control. 2020;49(5):597–602.
doi: 10.1016/j.ajic.2020.09.012
Robinson J, et al. Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery. Can J Anaesth. 1998;45(4):317–23.
doi: 10.1007/BF03012021
Guan W-J, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382(18):1708–20.
doi: 10.1056/NEJMoa2002032
Dunn G, Roberts C. Modelling method comparison data. Stat Methods Med Res. 1999;8(2):161–79.
doi: 10.1177/096228029900800205