Guidelines in Practice: Electrosurgical Safety.

active electrode electrosurgical injury fire risk preoperative briefing team communication

Journal

AORN journal
ISSN: 1878-0369
Titre abrégé: AORN J
Pays: United States
ID NLM: 0372403

Informations de publication

Date de publication:
07 2021
Historique:
received: 11 03 2021
accepted: 12 03 2021
entrez: 28 6 2021
pubmed: 29 6 2021
medline: 13 8 2021
Statut: ppublish

Résumé

Surgeons routinely use electrosurgical devices to cut and coagulate tissue during surgical procedures. However, hazards associated with electrosurgery (eg, burns, electrical shock, fire) can place patients or personnel at risk. Perioperative nurses should standardize processes, preoperatively assess the risks for electrosurgical injuries, and participate in education activities on electrosurgical safety to help prevent injuries from occurring. The AORN "Guideline for electrosurgical safety" provides guidance to perioperative personnel for safe use of electrosurgical units, electrocautery devices, and argon-enhanced coagulators. This article discusses prevention of electrosurgical unit injuries, including those that can be caused by electrosurgical accessories. A scenario describes how a team investigating two incidents related to use of electrosurgery uses an assessment tool to identify risks for injury and includes a report of these risks in the surgical briefing. Perioperative RNs should review the entire guideline for additional information when creating and updating policies and procedures for electrosurgical safety.

Identifiants

pubmed: 34181252
doi: 10.1002/aorn.13421
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

60-72

Informations de copyright

© AORN, Inc, 2021.

Références

Meeuwsen FC, Guédon ACP, Arkenbout EA, van der Elst M, Dankelman J, van den Dobbelsteen JJ. The art of electrosurgery: trainees and experts. Surg Innov. 2017;24(4):373-378.
Guideline for electrosurgical safety. In: Guidelines for Perioperative Practice. Denver, CO: AORN, Inc; 2021:83-108.
Odell RC. Surgical complications specific to monopolar electrosurgical energy: engineering changes that have made electrosurgery safer. J Minim Invasive Gynecol. 2013;20(3):288-298.
Hannah J. Probable postpolypectomy thermal burn: a case study. Gastroenterol Nurs. 2018;41(3):244-247.
Saaiq M, Zaib S, Ahmad S. Electrocautery burns: experience with three cases and review of literature. Ann Burns Fire Disasters. 2012;25(4):203-206.
Huffman SD, Huffman NP, Lewandowski RJ, Brown DB. Radiofrequency ablation complicated by skin burn. Semin Intervent Radiol. 2011;28(2):179-182.
Bansal A, Bhama JK, Varga JM, Toyoda Y. Airway fire during double-lung transplantation. Interact Cardiovasc Thorac Surg. 2013;17(6):1059-1060.
Jones DB, Brunt LM, Feldman LS, Mikami DJ, Robinson TN, Jones SB. Safe energy use in the operating room. Curr Probl Surg. 2015;52(11):447-468.
Law KSK, Abbott JA, Lyons SD. Energy sources for gynecologic laparoscopic surgery: a review of the literature. Obstet Gynecol Surv. 2014;69(12):763-776.
Sapienza P, Venturini L, Cigna E, Sterpetti AV, Biacchi D, di Marzo L. Deep gluteal grounding pad burn after abdominal aortic aneurysm repair. Ann Ital Chir. 2015;86:S2239253X15023944.
Humes DJ, Ahmed I, Lobo DN. The pedicle effect and direct coupling: delayed thermal injuries to the bile duct after laparoscopic cholecystectomy. Arch Surg. 2010;145(1):96-98.
Cormier B, Nezhat F, Sternchos J, Sonoda Y, Leitao MM Jr. Electrocautery-associated vascular injury during robotic-assisted surgery. Obstet Gynecol. 2012;120(2, pt 2):491-493.
Cassaro S. Delayed manifestations of laparoscopic bowel injury. Am Surg. 2015;81(5):478-482.
Guideline for safe use of energy-generating devices. In: Guidelines for Perioperative Practice. Denver, CO: AORN, Inc; 2020:83-114.
Guideline for laser safety. In: Guidelines for Perioperative Practice. Denver, CO: AORN, Inc; 2021:421-442.
Guideline for a safe environment of care. In: Guidelines for Perioperative Practice. Denver, CO: AORN, Inc; 2021:109-144.
Medical device reporting (MDR): how to report medical device problems. US Food and Drug Administration. https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. Updated October 20, 2020. Accessed March 16, 2021.
Guideline for team communication. In: Guidelines for Perioperative Practice. Denver, CO: AORN, Inc; 2021:1065-1096.
AORN Fire Safety Tool Kit. AORN. https://www.aorn.org/guidelines/clinical-resources/tool-kits/fire-safety-tool-kit [member access only]. Accessed March 16, 2021.

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH