An image fusion system for corrective osteotomy of distal radius malunion.

Computed tomography Corrective osteotomy Distal radius malunion Fluoroscopy Image fusion Preoperative plan

Journal

Biomedical engineering online
ISSN: 1475-925X
Titre abrégé: Biomed Eng Online
Pays: England
ID NLM: 101147518

Informations de publication

Date de publication:
30 Jun 2021
Historique:
received: 14 12 2020
accepted: 20 06 2021
entrez: 1 7 2021
pubmed: 2 7 2021
medline: 15 12 2021
Statut: epublish

Résumé

To provide surgical support for corrective osteotomy, we developed an image fusion system for three-dimensional (3D) preoperative planning and fluoroscopy. To assess the utility of this image fusion system, we evaluated the reproducibility of preoperative planning for corrective osteotomy of dorsally angulated distal radius malunion using the system and compared reproducibility without using the system. Ten wrists from 10 distal radius malunion patients who underwent corrective osteotomy were evaluated. 3D preoperative planning and the image fusion system were used for the image fusion group (n = 5). Only 3D preoperative planning was used for the control group (n = 5). 3D preoperative planning was performed for both groups in order to assess reduction, placement, and the choice of implants. In the image fusion group, the outline of the planned image was displayed on a monitor and overlapped with fluoroscopy images during surgery. Reproducibility was evaluated using preoperative plan and postoperative 3D images. Images were compared with the 3D coordinates of the radial styloid process (1), the volar and dorsal edges of the sigmoid notch (2) (3), and the barycentric coordinates of the three reference points. The reproducibility of the preoperative plan was evaluated by the distance of the coordinates between the plan and postoperative images for the reference points. The distances between preoperative planning and postoperative reduction in the image fusion group were 2.1 ± 1.1 mm, 1.8 ± 0.7 mm, 1.9 ± 0.9 mm, and 1.4 ± 0.7 mm for reference points (1), (2), (3), and the barycenter, respectively. The distances between preoperative planning and postoperative reduction in the control group were 3.7 ± 1.0 mm, 2.8 ± 2.0 mm, 1.7 ± 0.8 mm, and 1.8 ± 1.2 mm for reference points (1), (2), (3), and the barycenter, respectively. The difference in reference point (1) was significantly smaller in the image fusion group than in the control group (P < 0.05). Corrective osteotomy using an image fusion system will become a new surgical support method for fracture malunion. Trial registration Registered as NCT03764501 at ClinicalTrials.gov.

Sections du résumé

BACKGROUND BACKGROUND
To provide surgical support for corrective osteotomy, we developed an image fusion system for three-dimensional (3D) preoperative planning and fluoroscopy. To assess the utility of this image fusion system, we evaluated the reproducibility of preoperative planning for corrective osteotomy of dorsally angulated distal radius malunion using the system and compared reproducibility without using the system.
METHODS METHODS
Ten wrists from 10 distal radius malunion patients who underwent corrective osteotomy were evaluated. 3D preoperative planning and the image fusion system were used for the image fusion group (n = 5). Only 3D preoperative planning was used for the control group (n = 5). 3D preoperative planning was performed for both groups in order to assess reduction, placement, and the choice of implants. In the image fusion group, the outline of the planned image was displayed on a monitor and overlapped with fluoroscopy images during surgery. Reproducibility was evaluated using preoperative plan and postoperative 3D images. Images were compared with the 3D coordinates of the radial styloid process (1), the volar and dorsal edges of the sigmoid notch (2) (3), and the barycentric coordinates of the three reference points. The reproducibility of the preoperative plan was evaluated by the distance of the coordinates between the plan and postoperative images for the reference points.
RESULTS RESULTS
The distances between preoperative planning and postoperative reduction in the image fusion group were 2.1 ± 1.1 mm, 1.8 ± 0.7 mm, 1.9 ± 0.9 mm, and 1.4 ± 0.7 mm for reference points (1), (2), (3), and the barycenter, respectively. The distances between preoperative planning and postoperative reduction in the control group were 3.7 ± 1.0 mm, 2.8 ± 2.0 mm, 1.7 ± 0.8 mm, and 1.8 ± 1.2 mm for reference points (1), (2), (3), and the barycenter, respectively. The difference in reference point (1) was significantly smaller in the image fusion group than in the control group (P < 0.05).
CONCLUSION CONCLUSIONS
Corrective osteotomy using an image fusion system will become a new surgical support method for fracture malunion. Trial registration Registered as NCT03764501 at ClinicalTrials.gov.

Identifiants

pubmed: 34193171
doi: 10.1186/s12938-021-00901-8
pii: 10.1186/s12938-021-00901-8
pmc: PMC8244167
doi:

Banques de données

ClinicalTrials.gov
['NCT03764501']

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

66

Subventions

Organisme : Grant-in-Aid for Scientific Research
ID : 19K09582
Organisme : AMED
ID : A324TS

Références

Strategies Trauma Limb Reconstr. 2015 Aug;10(2):109-16
pubmed: 26350551
Int J Comput Assist Radiol Surg. 2018 Apr;13(4):507-518
pubmed: 29110185
Tech Hand Up Extrem Surg. 2006 Dec;10(4):224-30
pubmed: 17159478
Clin Orthop Relat Res. 2006 Sep;450:179-85
pubmed: 16721354
J Am Acad Orthop Surg. 1997 Oct;5(5):270-281
pubmed: 10795063
J Wrist Surg. 2013 Nov;2(4):306-14
pubmed: 24436834
J Hand Surg Am. 1989 Jul;14(4):679-87
pubmed: 2787817
J Bone Joint Surg Am. 2008 Nov;90(11):2375-89
pubmed: 18978406
Injury. 2017 Mar;48(3):731-737
pubmed: 28179058
Comput Aided Surg. 2001;6(3):160-9
pubmed: 11747134
J Am Acad Orthop Surg. 2007 Jan;15(1):27-40
pubmed: 17213380
Eur Radiol. 2005 Apr;15(4):792-7
pubmed: 15146292
J Bone Joint Surg Am. 2005 Jul;87(7):1503-9
pubmed: 15995117
Med Biol Eng Comput. 2013 Jul;51(7):791-7
pubmed: 23460197
J Hand Surg Am. 2008 Jul-Aug;33(6):835-40
pubmed: 18656752
J Hand Surg Am. 2017 Dec;42(12):1031.e1-1031.e8
pubmed: 28888571
Strategies Trauma Limb Reconstr. 2017 Aug;12(2):77-89
pubmed: 28444580
J Hand Surg Am. 2016 Mar;41(3):464-9
pubmed: 26787406
J Bone Joint Surg Am. 1980;62(4):613-9
pubmed: 6155380
J Hand Surg Am. 2002 Mar;27(2):223-32
pubmed: 11901381
J Orthop Surg Res. 2019 Nov 6;14(1):342
pubmed: 31694677
J Hand Surg Am. 2020 May;45(5):433-442
pubmed: 32220492
Int J Med Robot. 2014 Jun;10(2):196-202
pubmed: 24106094
J Hand Surg Am. 2003 Nov;28(6):951-8
pubmed: 14642510
Orthopedics. 2013 Feb;36(2):e193-9
pubmed: 23380014
Orthopedics. 2013 Apr;36(4):e457-62
pubmed: 23590785

Auteurs

Yuichi Yoshii (Y)

Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan. yyoshii@tokyo-med.ac.jp.

Takeshi Ogawa (T)

Department of Orthopaedic Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, 305-8576, Japan.

Yuki Hara (Y)

Department of Orthopaedic Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, 305-8576, Japan.

Yasukazu Totoki (Y)

Department of Orthopaedic Surgery, University of Tsukuba Hospital, Tsukuba, Ibaraki, 305-8576, Japan.

Tomoo Ishii (T)

Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki, 300-0395, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH