Effects on the thickness of single-layer mouthguards with different model positions on the forming table and different sheet frame shapes for the forming device.

model position mouthguard sheet frame shape thermoforming thickness

Journal

Dental traumatology : official publication of International Association for Dental Traumatology
ISSN: 1600-9657
Titre abrégé: Dent Traumatol
Pays: Denmark
ID NLM: 101091305

Informations de publication

Date de publication:
Feb 2022
Historique:
revised: 01 06 2021
received: 05 04 2021
accepted: 02 06 2021
pubmed: 2 7 2021
medline: 13 1 2022
entrez: 1 7 2021
Statut: ppublish

Résumé

Effectiveness and safety of mouthguards are greatly affected by their thickness. The aim of this study was to clarify the influence of the frame shape of the forming device on how the model position on the forming table affects the anterior and posterior mouthguard thickness. Mouthguards were thermoformed using 4.0-mm-thick ethylene-vinyl-acetate sheets and a vacuum forming device. Square sheets were fixed with the square frame of the forming device. Circular sheets were fixed to the forming device with a circular frame. The model was placed with its anterior rim positioned 40, 30, 20, or 10 mm from the front of the forming table. The model position was marked on the forming table so that it was constant under each condition. Six mouthguards were fabricated for each condition. Mouthguard thicknesses of the incisal edge, labial and buccal surfaces, and the cusp were measured. Differences in the rate of thickness reduction due to frame shapes and model positions were analyzed by two-way ANOVA. Difference in the thickness reduction rate depending on the frame shape was observed on the labial and buccal surfaces, and it was significantly greater with the circular frame than with the square frame (p < .01). In the anterior region, the thickness reduction rate tended to increase as the model position was moved toward the front of the forming table. The thickness reduction rate of the posterior portion was lowest when the model's molar was positioned at the center of the forming table. The labial thickness of the mouthguard was not affected by the frame shape if the distance from the model to the frame was larger than the model height. However, the buccal thickness was thinner with the circular frame than with the square frame regardless of the model position.

Sections du résumé

BACKGROUND/AIM OBJECTIVE
Effectiveness and safety of mouthguards are greatly affected by their thickness. The aim of this study was to clarify the influence of the frame shape of the forming device on how the model position on the forming table affects the anterior and posterior mouthguard thickness.
MATERIALS AND METHODS METHODS
Mouthguards were thermoformed using 4.0-mm-thick ethylene-vinyl-acetate sheets and a vacuum forming device. Square sheets were fixed with the square frame of the forming device. Circular sheets were fixed to the forming device with a circular frame. The model was placed with its anterior rim positioned 40, 30, 20, or 10 mm from the front of the forming table. The model position was marked on the forming table so that it was constant under each condition. Six mouthguards were fabricated for each condition. Mouthguard thicknesses of the incisal edge, labial and buccal surfaces, and the cusp were measured. Differences in the rate of thickness reduction due to frame shapes and model positions were analyzed by two-way ANOVA.
RESULTS RESULTS
Difference in the thickness reduction rate depending on the frame shape was observed on the labial and buccal surfaces, and it was significantly greater with the circular frame than with the square frame (p < .01). In the anterior region, the thickness reduction rate tended to increase as the model position was moved toward the front of the forming table. The thickness reduction rate of the posterior portion was lowest when the model's molar was positioned at the center of the forming table.
CONCLUSIONS CONCLUSIONS
The labial thickness of the mouthguard was not affected by the frame shape if the distance from the model to the frame was larger than the model height. However, the buccal thickness was thinner with the circular frame than with the square frame regardless of the model position.

Identifiants

pubmed: 34197692
doi: 10.1111/edt.12701
doi:

Types de publication

Journal Article

Langues

eng

Pagination

88-94

Subventions

Organisme : Nippon Dental University Intramural Research Fund

Informations de copyright

© 2021 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Références

Verissimo C, Costa PV, Santos-Filho PC, Tantbirojn D, Versluis A, Soares CJ. Custom-fitted EVA mouthguards: what is the ideal thickness? A dynamic finite element impact study. Dent Traumatol. 2016;32:95-102.
Gialain IO, Coto NP, Driemeier L, Noritomi PY, Dias RB. A three-dimensional finite element analysis of the sports mouthguard. Dent Traumatol. 2016;32:409-15.
Bochnig MS, Oh MJ, Nagel T, Ziegler F, Jost-Brinkmann PG. Comparison of the shock absorption capacities of different mouthguards. Dent Traumatol. 2017;33:205-13.
Gawlak D, Mańka-Malara K, Mierzwińska-Nastalska E, Gieleta R, Kamiński T, Łuniewska M. A comparison of impact force reduction by polymer materials used for mouthguard fabrication. Acta Bioeng Biomech. 2017;19:89-95.
Tribst JPM, de Oliveira Dal Piva AM, Borges ALS, Bottino MA. Influence of custom-made and stock mouthguard thickness on biomechanical response to a simulated impact. Dent Traumatol. 2018;34:429-37.
Bemelmanns P, Pfeiffer P. Shock absorption capacities of mouthguards in different types and thicknesses. Int J Sports Med. 2001;22:149-53.
Westerman B, Stringfellow PM, Eccleston JA. EVA mouthguards: how thick should they be? Dent Traumatol. 2002;18:24-7.
Geary JL, Kinirons MJ. Post thermoforming dimensional changes of ethylene vinyl acetate used in custom-made mouthguards for trauma prevention: a pilot study. Dent Traumatol. 2008;24:350-5.
Maeda M, Takeda T, Nakajima K, Shibusawa M, Kurokawa K, Shimada A, et al In search of necessary mouthguard thickness: part 1 from the view point of shock absorption ability. J Jpn Prosthodont. 2008;52:211-9.
Barkhoudarian G, Hovda DA, Giza CC. The molecular pathophysiology of concussive brain injury. Clin Sports Med. 2011;30:33-48.
Tanaka Y, Tsugawa T, Maeda Y. Effect of mouthguards on impact to the craniomandibular complex. Dent Traumatol. 2017;33:51-6.
Firmiano TC, Oliveira MTF, de Souza JB, Soares CJ, Versluis A, Veríssimo C. Influence of impacted canines on the stress distribution during dental trauma with and without a mouthguard. Dent Traumatol. 2019;35:276-84.
Tribst JPM, Dal Piva AMO, Bottino MA, Kleverlaan CJ, Koolstra JH. Mouthguard use and TMJ injury prevention with different occlusions: a three-dimensional finite element analysis. Dent Traumatol. 2020;36:662-9.
Takeuchi M, Togaya N. Effectively of thermoforming process for fabricating of intraoral apparatus. Tokyo. Japan: Sunashobo; 2006, p. 21-6, 33-44, 54-5, 62-7 (in Japanese).
Mizuhashi F, Koide K, Takahashi M. Thickness and fit of mouthguard according to changing the holding conditions and the heating conditions of the mouthguard sheet. Dent Traumatol. 2014;30:140-6.
Takahashi M, Koide K, Mizuhashi F, Sato T. Investigation of vacuum forming techniques for reduction of loss in mouthguard thickness: part 2 effects of sheet grooving and thermal shrinkage. Dent Traumatol. 2015;31:314-7.
Farrington T, Coward T, Onambele-Pearson G, Taylor RL, Earl P, Winwood K. An investigation into the relationship between thickness variations and manufacturing techniques of mouthguards. Dent Traumatol. 2016;32:14-21.
Takahashi M, Araie Y, Satoh Y, Iwasaki S. Shape change in mouthguard sheets during thermoforming: Part 2 Effect of the anteroposterior position of the model on mouthguard thickness. Dent Traumatol. 2017;33:114-20.
Takahashi M, Bando Y. Thermoforming method to effectively maintain mouthguard thickness: effect of moving the model position just before vacuum formation. Dent Traumatol. 2019;35:121-7.
Takahashi M, Koide K, Mizuhashi F. Differences in the thickness of mouthguards fabricated from ethylene vinyl acetate copolymer sheets with differently arranged v-shaped grooves: part 2 effect of shape on the working model. Dent Traumatol. 2014;30:472-6.
Takahashi M, Koide K. Variation in mouthguard thickness according to heating conditions during fabrication: part 2 sheet shape and effect of thermal shrinkage. Dent Traumatol. 2016;32:185-91.
Takahashi M, Koide K, Satoh Y, Iwasaki S. Shape change in mouthguard sheets during thermoforming. Dent Traumatol. 2016;32:379-84.
Takahashi M, Bando Y. Movement of model position just before vacuum forming to ensure mouthguard thickness: part 2 effect of model moving distance. Dent Traumatol. 2019;35:291-5.
Takahashi M, Bando Y. Thermoforming technique for suppressing reduction in mouthguard thickness: part 2 Effect of model height and model moving distance. Dent Traumatol. 2020;36:543-50.
Takahashi M, Koide K, Mizuhashi F. Optimal heating conditions for forming a mouthguard using a circle tray: effect of different conditions on the thickness and fit of formed mouthguards. J Prosthodont Res. 2014;58:171-6.
Takahashi M, Koide K, Iwasaki S. Method for effectively maintaining the thickness of mouthguards fabricated using EVA sheets and a circle tray: Influence of grooved sheet and heating conditions. Dent Traumatol. 2016;32:206-11.

Auteurs

Mutsumi Takahashi (M)

Department of Physiology, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan.

Yogetsu Bando (Y)

BANDO Dental Clinic, Ishikawa, Japan.

Articles similaires

Humans Surgical Staplers Surgical Stapling Postoperative Complications Treatment Outcome
Animals Robotics Algorithms Sperm Whale Vocalization, Animal

Understanding the sense of self through robotics.

Tony J Prescott, Kai Vogeley, Agnieszka Wykowska
1.00
Robotics Humans Animals Equipment Design Self Concept

Bank vole genomics links determinate and indeterminate growth of teeth.

Zachary T Calamari, Andrew Song, Emily Cohen et al.
1.00
Animals Arvicolinae Genomics Mice Tooth

Classifications MeSH