Preoperative planning of total knee arthroplasty: reliability of axial alignment using a three-dimensional planning approach.


Journal

Acta radiologica (Stockholm, Sweden : 1987)
ISSN: 1600-0455
Titre abrégé: Acta Radiol
Pays: England
ID NLM: 8706123

Informations de publication

Date de publication:
Aug 2022
Historique:
pubmed: 8 7 2021
medline: 9 7 2022
entrez: 7 7 2021
Statut: ppublish

Résumé

Preoperative templating of total knee arthroplasty (TKA) can nowadays be performed three-dimensionally with software solutions using computed tomography (CT) datasets. Currently there is no consensus concerning the axial orientation of TKA components in three-dimensional (3D) planning. To assess intra-/inter-observer reliability of detection of different bony landmarks in planning axial component alignment using axial CT images and 3D reconstructions. Intra- and inter-observer reliability of determination of four predefined axial femoral and tibial axes was calculated using data from CT scans. Axes determination was performed on the axial slices and on the 3D reconstruction using preoperative planning software. In summary, 61 datasets were analyzed by one medical student (intra-observer reliability) and 15 datasets were analyzed by four different observers independently (inter-observer reliability). For the femur, clinical epicondylar axis and posterior condylar axis showed the best reliability with an inter-observer variability of 0.7° and 0.5°, respectively. For the tibia, posterior condylar axis provided best reliability (inter-observer variability: 1.7°). Overall variability was greater for tibial than for femoral axes. Reliability of axis determination was more accurate using axial CT slices rather than 3D reconstructions. The femoral clinical epicondylar axis is highly reliable. Landmarks for the tibia are not as easily identifiable as for the femur. The tibial posterior condylar axis presents the axis with highest reliability. Based on these results, clinical epicondylar axis for orientation of the femoral TKA component and posterior condylar axis for the tibial implant, both defined on axial slices can be recommended.

Sections du résumé

BACKGROUND BACKGROUND
Preoperative templating of total knee arthroplasty (TKA) can nowadays be performed three-dimensionally with software solutions using computed tomography (CT) datasets. Currently there is no consensus concerning the axial orientation of TKA components in three-dimensional (3D) planning.
PURPOSE OBJECTIVE
To assess intra-/inter-observer reliability of detection of different bony landmarks in planning axial component alignment using axial CT images and 3D reconstructions.
MATERIAL AND METHODS METHODS
Intra- and inter-observer reliability of determination of four predefined axial femoral and tibial axes was calculated using data from CT scans. Axes determination was performed on the axial slices and on the 3D reconstruction using preoperative planning software. In summary, 61 datasets were analyzed by one medical student (intra-observer reliability) and 15 datasets were analyzed by four different observers independently (inter-observer reliability).
RESULTS RESULTS
For the femur, clinical epicondylar axis and posterior condylar axis showed the best reliability with an inter-observer variability of 0.7° and 0.5°, respectively. For the tibia, posterior condylar axis provided best reliability (inter-observer variability: 1.7°). Overall variability was greater for tibial than for femoral axes. Reliability of axis determination was more accurate using axial CT slices rather than 3D reconstructions.
CONCLUSION CONCLUSIONS
The femoral clinical epicondylar axis is highly reliable. Landmarks for the tibia are not as easily identifiable as for the femur. The tibial posterior condylar axis presents the axis with highest reliability. Based on these results, clinical epicondylar axis for orientation of the femoral TKA component and posterior condylar axis for the tibial implant, both defined on axial slices can be recommended.

Identifiants

pubmed: 34229468
doi: 10.1177/02841851211029076
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1051-1061

Auteurs

Stefan Tiefenboeck (S)

Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Stefan Sesselmann (S)

Institute for Medical Engineering, Ostbayerische Technische Hochschule Amberg-Weiden, Weiden, Germany.

Dominic Taylor (D)

Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Raimund Forst (R)

Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Frank Seehaus (F)

Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH