Transcatheter mitral valve-in-valve-in-valve replacement with transseptal puncture in the presence of an atrial septal occluder device.
2D echocardiography
TEE
atrial septal defect
bioprosthetic mitral valve stenosis
doppler echocardiography
three-dimensional echocardiography
Journal
Echocardiography (Mount Kisco, N.Y.)
ISSN: 1540-8175
Titre abrégé: Echocardiography
Pays: United States
ID NLM: 8511187
Informations de publication
Date de publication:
08 2021
08 2021
Historique:
revised:
07
04
2021
received:
09
03
2021
accepted:
02
05
2021
pubmed:
8
7
2021
medline:
14
9
2021
entrez:
7
7
2021
Statut:
ppublish
Résumé
Quite often the iatrogenic atrial septal defect created after percutaneous transcatheter mitral valve replacement procedures is closed with an atrial septal occluder device thus precluding further transseptal interventions if required. In this case report, we describe a patient who previously underwent a valve-in-valve transcatheter mitral valve replacement and iatrogenic atrial septal defect closure with an Amplatzer device, who developed severe prosthetic mitral valve stenosis. This patient required a second percutaneous valve-in-valve in-valve procedure with a transseptal puncture in the presence of an atrial septal occluder device.
Types de publication
Case Reports
Langues
eng
Sous-ensembles de citation
IM
Pagination
1425-1429Informations de copyright
© 2021 Wiley Periodicals LLC.
Références
Shah M, Jorde UP. Percutaneous mitral valve interventions (repair): current indications and future perspectives. Front Cardiovasc Med. 2019;6:88. Published 2019 Jul 12. https://doi.org/10.3389/fcvm.2019.00088
Rogers T, Slack M, Waksman R. Overview of the 2016 US Food and Drug Administration circulatory system devices panel meeting on the Amplatzer Patent Foramen Ovale Occluder. Am J Cardiol. 2017;1:153-215. https://doi.org/10.1016/j.amjcard.2016.09.026
Sang CH, Dong JZ, Long DY, et al. Transseptal puncture and catheter ablation of atrial fibrillation in patients with atrial septal occluder: initial experience of a single centre. Europace. 2018;20(9):1468-1474. https://doi.org/10.1093/europace/eux282. PMID: 29106529
Chen K, Sang C, Dong J, Ma C. Transseptal puncture through Amplatzer septal occluder device for catheter ablation of atrial fibrillation: use of balloon dilatation technique. J Cardiovasc Electrophysiol. 2012;23(10):1139-1141. https://doi.org/10.1111/j.1540-8167.2012.02306.x. Epub 2012 Apr 17 PMID: 22510167
Pedersen ME, Gill JS, Qureshi SA, Rinaldi CA. Successful transseptal puncture for radiofrequency ablation of left atrial tachycardia after closure of secundum atrial septal defect with Amplatzer septal occluder. Cardiol Young. 2010;20(2):226-228. https://doi.org/10.1017/S1047951110000168. Epub 2010 Mar 22 PMID: 20307333
Gloekler S, Shakir S, Meier B. Transseptal puncture through amplatzer atrial septal occluder for left atrial appendage closure. JACC Cardiovasc Interv. 2017;10(21):2222-2223. https://doi.org/10.1016/j.jcin.2017.04.038. PMID: 29122135
Beri N, Singh GD, Smith TW, Fan D, Boyd WD, Rogers JH. Iatrogenic atrial septal defect closure after transseptal mitral valve interventions: Indications and outcomes. Catheter Cardiovasc Interv. 2019;94:829-836. https://doi.org/10.1002/ccd.2829412