Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture.


Journal

Journal of orthopaedic surgery and research
ISSN: 1749-799X
Titre abrégé: J Orthop Surg Res
Pays: England
ID NLM: 101265112

Informations de publication

Date de publication:
07 Jul 2021
Historique:
received: 30 03 2021
accepted: 23 06 2021
entrez: 8 7 2021
pubmed: 9 7 2021
medline: 3 11 2021
Statut: epublish

Résumé

Metacarpal shaft fractures are a common hand trauma. The current surgical fixation options for such fractures include percutaneous Kirschner wire pinning and nonlocking and locking plate fixation. Although bone plate fixation, compared with Kirschner wire pinning, has superior fixation ability, a consensus has not been reached on whether the bone plate is better placed on the dorsal or lateral side. The purpose of this study was to evaluate the fixation of locking and regular bone plates on the dorsal and lateral sides of a metacarpal shaft fracture. Thirty-five artificial metacarpal bones were used in the experiment. Metacarpal shaft fractures were created using a saw blade, which were then treated with four types of fixation as follows: (1) a locking plate with four locking bicortical screws on the dorsal side (LP_D); (2) a locking plate with four locking bicortical screws on the lateral side (LP_L); (3) a regular plate with four regular bicortical screws on the dorsal side (RP_D); (4) a regular plate with four regular bicortical screws on the lateral side (RP_D); and (5) two K-wires (KWs). All specimens were tested through cantilever bending tests on a material testing system. The maximum fracture force and stiffness of the five fixation types were determined based on the force-displacement data. The maximum fracture force and stiffness of the specimens with metacarpal shaft fractures were first analyzed using one-way analysis of variance and Tukey's test. The maximum fracture force results of the five types of metacarpal shaft fracture were as follows: LP_D group (230.1 ± 22.8 N, mean ± SD) ≅ RP_D group (228.2 ± 13.4 N) > KW group (94.0 ± 17.4 N) > LP_L group (59.0 ± 7.9 N) ≅ RP_L group (44.5 ± 3.4 N). In addition, the stiffness results of the five types of metacarpal shaft fracture were as follows: LP_D group (68.7 ± 14.0 N/mm) > RP_D group (54.9 ± 3.2 N/mm) > KW group (20.7 ± 5.8 N/mm) ≅ LP_L group (10.6 ± 1.7 N/mm) ≅ RP_L group (9.4 ± 1.2 N/mm). According to our results, the mechanical strength offered by lateral plate fixation of a metacarpal shaft fracture is so low that even KW fixation can offer relatively superior mechanical strength; this is regardless of whether a locking or nonlocking plate is used for lateral plate fixation. Such fixation can reduce the probability of extensor tendon adhesion. Nevertheless, our results indicated that when lateral plate fixation is used for fixating a metacarpal shaft fracture in a clinical setting, whether the mechanical strength offered by such fixation would be strong enough to support bone union remains questionable.

Sections du résumé

BACKGROUND BACKGROUND
Metacarpal shaft fractures are a common hand trauma. The current surgical fixation options for such fractures include percutaneous Kirschner wire pinning and nonlocking and locking plate fixation. Although bone plate fixation, compared with Kirschner wire pinning, has superior fixation ability, a consensus has not been reached on whether the bone plate is better placed on the dorsal or lateral side.
OBJECTIVE OBJECTIVE
The purpose of this study was to evaluate the fixation of locking and regular bone plates on the dorsal and lateral sides of a metacarpal shaft fracture.
MATERIALS AND METHODS METHODS
Thirty-five artificial metacarpal bones were used in the experiment. Metacarpal shaft fractures were created using a saw blade, which were then treated with four types of fixation as follows: (1) a locking plate with four locking bicortical screws on the dorsal side (LP_D); (2) a locking plate with four locking bicortical screws on the lateral side (LP_L); (3) a regular plate with four regular bicortical screws on the dorsal side (RP_D); (4) a regular plate with four regular bicortical screws on the lateral side (RP_D); and (5) two K-wires (KWs). All specimens were tested through cantilever bending tests on a material testing system. The maximum fracture force and stiffness of the five fixation types were determined based on the force-displacement data. The maximum fracture force and stiffness of the specimens with metacarpal shaft fractures were first analyzed using one-way analysis of variance and Tukey's test.
RESULTS RESULTS
The maximum fracture force results of the five types of metacarpal shaft fracture were as follows: LP_D group (230.1 ± 22.8 N, mean ± SD) ≅ RP_D group (228.2 ± 13.4 N) > KW group (94.0 ± 17.4 N) > LP_L group (59.0 ± 7.9 N) ≅ RP_L group (44.5 ± 3.4 N). In addition, the stiffness results of the five types of metacarpal shaft fracture were as follows: LP_D group (68.7 ± 14.0 N/mm) > RP_D group (54.9 ± 3.2 N/mm) > KW group (20.7 ± 5.8 N/mm) ≅ LP_L group (10.6 ± 1.7 N/mm) ≅ RP_L group (9.4 ± 1.2 N/mm).
CONCLUSION CONCLUSIONS
According to our results, the mechanical strength offered by lateral plate fixation of a metacarpal shaft fracture is so low that even KW fixation can offer relatively superior mechanical strength; this is regardless of whether a locking or nonlocking plate is used for lateral plate fixation. Such fixation can reduce the probability of extensor tendon adhesion. Nevertheless, our results indicated that when lateral plate fixation is used for fixating a metacarpal shaft fracture in a clinical setting, whether the mechanical strength offered by such fixation would be strong enough to support bone union remains questionable.

Identifiants

pubmed: 34233702
doi: 10.1186/s13018-021-02575-3
pii: 10.1186/s13018-021-02575-3
pmc: PMC8262013
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

441

Subventions

Organisme : China Medical University
ID : CMU109-MF-117
Organisme : Ministry of Science and Technology, Taiwan
ID : MOST 109-2221-E-039-005

Références

J Hand Surg Am. 2017 Mar;42(3):e159-e165
pubmed: 28259280
Hand (N Y). 2019 Jan;14(1):27-33
pubmed: 30192648
Hand (N Y). 2019 Mar;14(2):187-192
pubmed: 28933187
Case Rep Surg. 2016;2016:7515760
pubmed: 27843670
J Hand Surg Br. 1992 Apr;17(2):144-7
pubmed: 1588193
J Hand Surg Am. 2001 Sep;26(5):908-15
pubmed: 11561245
Eur J Trauma Emerg Surg. 2016 Apr;42(2):169-75
pubmed: 26038026
Arch Orthop Trauma Surg. 2017 Apr;137(4):567-572
pubmed: 28236187
J Hand Surg Am. 2000 Sep;25(5):817-23
pubmed: 11040296
Ulus Travma Acil Cerrahi Derg. 2015 Jul;21(4):279-84
pubmed: 26374415
Clin Orthop Relat Res. 1996 Jun;(327):38-46
pubmed: 8641080
J Orthop Trauma. 2015 Aug;29(8):e242-4
pubmed: 25714441
J Hand Surg Am. 1991 Sep;16(5):844-50
pubmed: 1940163
J Bone Joint Surg Am. 1958 Oct;40-A(5):1169-75
pubmed: 13587591
J Hand Surg Eur Vol. 2016 May;41(4):423-30
pubmed: 26329883
Clin Orthop. 1959;15:22-6
pubmed: 14434678
J Hand Surg Am. 2011 Apr;36(4):610-6
pubmed: 21463725
Hand Surg. 2015;20(1):99-105
pubmed: 25609282
Hand (N Y). 2016 Dec;11(4):421-426
pubmed: 28149208
Int Orthop. 2012 Aug;36(8):1641-6
pubmed: 22426933
J Orthop Surg Res. 2018 Jul 25;13(1):183
pubmed: 30045774
Clin Biomech (Bristol, Avon). 2015 Jun;30(5):405-10
pubmed: 25846324
Hand (N Y). 2013 Dec;8(4):454-9
pubmed: 24426966
Arch Orthop Trauma Surg. 2004 Oct;124(8):523-6
pubmed: 15278369
Clin Orthop Relat Res. 1996 Jun;(327):21-8
pubmed: 8641066
Ann R Coll Surg Engl. 2007 Apr;89(3):252-8
pubmed: 17394709

Auteurs

Yung-Cheng Chiu (YC)

School of Medicine, China Medical University, Taichung, 404, Taiwan.
Department of Orthopedic Surgery, China Medical University Hospital, Taichung, 404, Taiwan.

Cheng-En Hsu (CE)

Department of Orthopedics, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
Sports Recreation and Health Management Continuing Studies-Bachelor's Degree Completion Program, Tunghai University, Taichung, 407, Taiwan.

Tsung-Yu Ho (TY)

Department of Orthopedic Surgery, China Medical University Hospital, Taichung, 404, Taiwan.

Yen-Nien Ting (YN)

3D Printing Medical Research Center, China Medical University Hospital, Taichung, 404, Taiwan.

Ming-Tzu Tsai (MT)

Department of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan, ROC.

Jui-Ting Hsu (JT)

School of Dentistry, College of Dentistry, China Medical University, 91 Hsueh-Shih Road, Taichung, 40402, Taiwan. jthsu@mail.cmu.edu.tw.
Department of Bioinformatics and Medical Engineering, Asia University, Taichung, 413, Taiwan. jthsu@mail.cmu.edu.tw.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH