Feasibility of digital atrial fibrillation screening in an elderly population : The Ulm heart rhythm weeks.

Machbarkeit eines digitalen Screenings auf Vorhofflimmern bei Älteren : Die Ulmer Herzrhythmuswochen.

Journal

Herzschrittmachertherapie & Elektrophysiologie
ISSN: 1435-1544
Titre abrégé: Herzschrittmacherther Elektrophysiol
Pays: Germany
ID NLM: 9425873

Informations de publication

Date de publication:
Sep 2021
Historique:
received: 01 04 2021
accepted: 17 06 2021
pubmed: 10 7 2021
medline: 7 9 2021
entrez: 9 7 2021
Statut: ppublish

Résumé

Atrial fibrillation (AF) screening in risk populations has the potential to prevent strokes. The authors tested the feasibility of a digital program with initial photoplethysmographic (PPG) self-screening and cardiologist-attended electrocardiographic (ECG) confirmation of screen-positive cases. Inhabitants of the city of Ulm aged ≥ 65 years were invited to participate. After digital consent, participants were given access to a smartphone application for 14 days of self-screening (two recordings per day recommended). Screen-positive participants without known AF were invited to present to a cardiologist for AF confirmation with a 14-day ECG event recorder. PPG recordings were first analyzed by algorithm using a combination of linear and non-linear methods. The quality of pathological (classified by algorithm) PPG and all ECG recordings were checked by a telecare service. Primary outcomes included adherence to the screening protocol defined as the proportion of participants performing at least 14 PPG recordings (or until documentation of absolute arrhythmia) and the proportion of pathological PPG and all ECG recordings rejected by the telecare center. A total of 215 participants registered. Of these, 204 (95%) performed at least one recording and 169 (79%) reached the performance target of two sufficient measurements per day; 75 PPG recordings were automatically classified as pathological by algorithm; 14 (19%) were rejected by the telecare service due to poor quality. Of the 12 participants with a suspected first diagnosis of AF, five visited a cardiologist as part of the study. Of 1090 ECG recordings obtained, 390 (36%) were qualified as non-diagnostic. AF was confirmed in three cases. A digital AF screening program with initial self-screening and referral of screen-positive cases to a cardiologist-attended ECG-confirmation service is feasible with meaningful results in an elderly risk population. However, the availability of the target population of persons > 65 years of age for such a digital screening program appears to be limited despite extensive public relations activities. FRAGESTELLUNG: Ein Screening von Risikopopulationen auf Vorhofflimmern (VHF) kann Schlaganfälle verhindern. Wir untersuchten die Machbarkeit eines digitalen Konzepts mit initialem photoplethysmographischem (PPG) Eigenscreening und fachkardiologischer EKG-Bestätigung (EKG: Elektrokardiographie) positiver Screeningergebnisse. Einwohner von Ulm ab 65 Jahren ohne bekanntes VHF wurden zur Teilnahme eingeladen. Die Teilnehmer erhielten Zugang zu einer Smartphone-Applikation für ein 14-tägiges Eigenscreening mit 2 empfohlenen Messungen pro Tag. Bei positivem Screeningergebnis erhielten die Teilnehmer zur Bestätigung des VHF einen 14-Tages-EKG-Ereignisrekorder. Nach initialer Analyse der PPG-Aufzeichnungen durch einen Algorithmus wurde die Qualität der als pathologisch klassifizierten PPG sowie aller EKG-Aufzeichnungen durch einen „telecare service“ überprüft. Primäre Endpunkte waren die Adhärenz zum Screeningprotokoll sowie der Anteil pathologischer PPG- und EKG-Aufzeichnungen, die vom „telecare center“ als qualitativ unzureichend beurteilt worden waren. Es registrierten sich 215 Teilnehmer. Davon führten 204 (95 %) zumindest eine Messung durch und 169 (79 %) 2 auswertbare Messungen/Tag. Vom PPG-basierten Algorithmus als pathologisch klassifiziert wurden 75 PPG-Aufzeichnungen; vom „telecare center“ als qualitativ unzureichend beurteilt wurden 14 (19 %). Von den 12 Teilnehmern mit Verdacht auf Erstdiagnose von Vorhofflimmern stellten sich 5 kardiologisch vor. Bei diesen wurden 1090 EKG-Aufzeichnungen durchgeführt, von denen 390 (36 %) aufgrund von Artefakten als nicht diagnostisch eingestuft wurden. In 3 Fällen wurde VHF bestätigt. Ein digitales VHF-Screeningprogramm mit initialer Eigenmessung und Vermittlung auffälliger Fälle an einen teilnehmenden Kardiologen zur Durchführung einer EKG-Bestätigung kann in einer älteren Risikogruppe mit aussagekräftigen Ergebnissen durchgeführt werden. Die Zielgruppe aus Menschen über 65 ist aber für ein solches digitales Screeningprogramm trotz aufwändiger Öffentlichkeitsarbeit offenbar nur eingeschränkt erreichbar.

Autres résumés

Type: Publisher (ger)
FRAGESTELLUNG: Ein Screening von Risikopopulationen auf Vorhofflimmern (VHF) kann Schlaganfälle verhindern. Wir untersuchten die Machbarkeit eines digitalen Konzepts mit initialem photoplethysmographischem (PPG) Eigenscreening und fachkardiologischer EKG-Bestätigung (EKG: Elektrokardiographie) positiver Screeningergebnisse.

Identifiants

pubmed: 34241681
doi: 10.1007/s00399-021-00783-2
pii: 10.1007/s00399-021-00783-2
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

346-352

Informations de copyright

© 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Références

Kirchhof P et al (2020) Early rhythm-control therapy in patients with atrial fibrillation. N Engl J Med 383(14):1305–1316
doi: 10.1056/NEJMoa2019422
EAFT (European Atrial Fibrillation Trial) Study Group (1993) Secondary prevention in non-rheumatic atrial fibrillation after transient ischaemic attack or minor stroke. Lancet 342(8882):1255–1262
doi: 10.1016/0140-6736(93)92358-Z
Brasier N et al (2019) Detection of atrial fibrillation with a smartphone camera: first prospective, international, two-centre, clinical validation study (DETECT AF PRO). Europace 21(1):41–47
doi: 10.1093/europace/euy176
Koenig N et al (2016) Validation of a new heart rate measurement algorithm for fingertip recording of video signals with smartphones. Telemed J E Health 22(8):631–636
doi: 10.1089/tmj.2015.0212
Freedman B et al (2017) Screening for atrial fibrillation: a report of the AF-SCREEN international collaboration. Circulation 135(19):1851–1867
doi: 10.1161/CIRCULATIONAHA.116.026693
Friberg L et al (2014) High prevalence of atrial fibrillation among patients with ischemic stroke. Stroke 45(9):2599–2605
doi: 10.1161/STROKEAHA.114.006070
Wachter R et al (2017) Holter-electrocardiogram-monitoring in patients with acute ischaemic stroke (Find-AFRANDOMISED): an open-label randomised controlled trial. Lancet Neurol 16(4):282–290
doi: 10.1016/S1474-4422(17)30002-9
Sanna T et al (2014) Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 370(26):2478–2486
doi: 10.1056/NEJMoa1313600
Boriani G et al (2015) Asymptomatic atrial fibrillation: clinical correlates, management, and outcomes in the EORP-AF Pilot General Registry. Am J Med 128(5):509–518.e2
doi: 10.1016/j.amjmed.2014.11.026
Potpara TS et al (2013) A comparison of clinical characteristics and long-term prognosis in asymptomatic and symptomatic patients with first-diagnosed atrial fibrillation: the Belgrade Atrial Fibrillation Study. Int J Cardiol 168(5):4744–4749
doi: 10.1016/j.ijcard.2013.07.234
Martinez C, Katholing A, Freedman SB (2014) Adverse prognosis of incidentally detected ambulatory atrial fibrillation. A cohort study. Thromb Haemost 112(2):276–286
doi: 10.1160/TH4-04-0383
Siontis KC et al (2016) Typical, atypical, and asymptomatic presentations of new-onset atrial fibrillation in the community: characteristics and prognostic implications. Heart Rhythm 13(7):1418–1424
doi: 10.1016/j.hrthm.2016.03.003
Glotzer TV et al (2003) Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST). Circulation 107(12):1614–1619
doi: 10.1161/01.CIR.0000057981.70380.45
Healey JS et al (2012) Subclinical atrial fibrillation and the risk of stroke. N Engl J Med 366(2):120–129
doi: 10.1056/NEJMoa1105575
Swiryn S et al (2016) Clinical implications of brief device-detected atrial tachyarrhythmias in a cardiac rhythm management device population: results from the Registry of Atrial Tachycardia and Atrial Fibrillation Episodes. Circulation 134(16):1130–1140
doi: 10.1161/CIRCULATIONAHA.115.020252
Glotzer TV et al (2009) The relationship between daily atrial tachyarrhythmia burden from implantable device diagnostics and stroke risk: the TRENDS study. Circ Arrhythm Electrophysiol 2(5):474–480
doi: 10.1161/CIRCEP.109.849638
Kirchhof P et al (2017) Probing oral anticoagulation in patients with atrial high rate episodes: rationale and design of the non-vitamin K antagonist oral anticoagulants in patients with atrial high rate episodes (NOAH-AFNET 6) trial. Am Heart J 190:12–18
doi: 10.1016/j.ahj.2017.04.015
Lopes RD et al (2017) Rationale and design of the apixaban for the reduction of thrombo-embolism in patients with device-detected sub-clinical atrial fibrillation (ARTESiA) trial. Am Heart J 189:137–145
doi: 10.1016/j.ahj.2017.04.008
Hindricks G et al (2021) 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 42(5):373–498
doi: 10.1093/eurheartj/ehaa612
Perez MV et al (2019) Large-scale assessment of a smartwatch to identify atrial fibrillation. N Engl J Med 381(20):1909–1917
doi: 10.1056/NEJMoa1901183
Verbrugge FH et al (2019) Atrial fibrillation screening with photo-plethysmography through a smartphone camera. Europace 21(8):1167–1175
doi: 10.1093/europace/euz119
Guo Y et al (2019) Mobile photoplethysmographic technology to detect atrial fibrillation. J Am Coll Cardiol 74(19):2365–2375
doi: 10.1016/j.jacc.2019.08.019
Birkemeyer R et al (2020) A cost-effectiveness analysis model of preventicus atrial fibrillation screening from the point of view of statutory health insurance in Germany. Health Econ Rev 10(1):16
doi: 10.1186/s13561-020-00274-z
Svennberg E et al (2015) Mass screening for untreated atrial fibrillation: the STROKESTOP study. Circulation 131(25):2176–2184
doi: 10.1161/CIRCULATIONAHA.114.014343

Auteurs

Ralf Birkemeyer (R)

Herzklinik Ulm, Magirusstr. 49, 89077, Ulm/Donau, Germany. birkemeyer@me.com.

Laura Maisch (L)

University of Ulm, Ulm, Germany.

Tillman Dahme (T)

Department of Cardiology, University Hospital Ulm, Ulm, Germany.

Jochen Spieß (J)

Kardiologische Gemeinschaftspraxis Dres. Hofmeister, Spieß, Wohlfrom, Ulm, Germany.

Katharina Althaus (K)

Department of Neurology, University of Ulm, Ulm, Germany.

Steffen Schneider (S)

Institut für Herzinfarktforschung, Ludgwigshafen, Germany.

Ursula Ravens (U)

University of Freiburg, Freiburg, Germany.
Kompetenznetz Vorhofflimmern e. V., Münster, Germany.

Doreen Haase (D)

Kompetenznetz Vorhofflimmern e. V., Münster, Germany.

Ulrich Schotten (U)

Kompetenznetz Vorhofflimmern e. V., Münster, Germany.
Dept of Physiology, Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH