Diagnostic accuracy of the "4 A's Test" delirium screening tool for the postoperative cardiac surgery ward.
4AT
cardiac surgery
nursing
postoperative delirium
Journal
The Journal of thoracic and cardiovascular surgery
ISSN: 1097-685X
Titre abrégé: J Thorac Cardiovasc Surg
Pays: United States
ID NLM: 0376343
Informations de publication
Date de publication:
03 2023
03 2023
Historique:
received:
07
07
2020
revised:
12
05
2021
accepted:
12
05
2021
medline:
26
10
2023
pubmed:
11
7
2021
entrez:
10
7
2021
Statut:
ppublish
Résumé
Delirium is prevalent and underdetected among cardiac surgery patients on the postoperative ward. This study aimed to validate the 4 A's Test delirium screening tool and evaluate its accuracy both when used by research assistants and when subsequently implemented by nursing staff on the ward. This single-center, prospective observational study evaluated the performance of the 4 A's Test administered by research assistants (phase 1) and nursing staff (phase 2). Assessments were undertaken during the patients' first 3 postoperative days on the postcardiac surgery ward along with previous routine nurse-led Confusion Assessment Method assessments. These index tests were compared with a reference standard diagnosis of delirium based on Diagnostic and Statistical Manual of Mental Disorders 5th Edition criteria. Surveys regarding delirium screening were administered to nurses pre- and postimplementation of the 4 A's Test in phase 2 of the study. In phase 1, a total of 137 patients were enrolled, of whom 24.8% experienced delirium on the postoperative cardiac ward. The 4 A's Test had a sensitivity of 85% (95% confidence interval, 73-93) and a specificity of 90% (95% confidence interval, 85-93) compared with the reference standard. The nurse-assessed Confusion Assessment Method had a sensitivity of 23% (95% confidence interval, 13-37) and specificity of 100% (95% confidence interval, 99-100). In phase 2, nurses (n = 51) screened 179 patients for delirium using the 4 A's Test. Compared with the reference rater, the 4 A's Test had a sensitivity of 58% (95% confidence interval, 28-85) and specificity of 94% (95% confidence interval, 85-98). Postimplementation, 64% of nurses thought that the 4 A's Test improved their confidence in delirium detection, and 76% of nurses would consider routine 4 A's Test use. The 4 A's Test demonstrated moderate sensitivity and high specificity to detect delirium in a real-world setting after cardiac surgery on the postoperative ward. A modified model of use with less frequent administration, along with increased engagement of the postoperative team, is recommended to improve early delirium detection on the cardiac surgery postoperative ward.
Sections du résumé
BACKGROUND
Delirium is prevalent and underdetected among cardiac surgery patients on the postoperative ward. This study aimed to validate the 4 A's Test delirium screening tool and evaluate its accuracy both when used by research assistants and when subsequently implemented by nursing staff on the ward.
METHODS
This single-center, prospective observational study evaluated the performance of the 4 A's Test administered by research assistants (phase 1) and nursing staff (phase 2). Assessments were undertaken during the patients' first 3 postoperative days on the postcardiac surgery ward along with previous routine nurse-led Confusion Assessment Method assessments. These index tests were compared with a reference standard diagnosis of delirium based on Diagnostic and Statistical Manual of Mental Disorders 5th Edition criteria. Surveys regarding delirium screening were administered to nurses pre- and postimplementation of the 4 A's Test in phase 2 of the study.
RESULTS
In phase 1, a total of 137 patients were enrolled, of whom 24.8% experienced delirium on the postoperative cardiac ward. The 4 A's Test had a sensitivity of 85% (95% confidence interval, 73-93) and a specificity of 90% (95% confidence interval, 85-93) compared with the reference standard. The nurse-assessed Confusion Assessment Method had a sensitivity of 23% (95% confidence interval, 13-37) and specificity of 100% (95% confidence interval, 99-100). In phase 2, nurses (n = 51) screened 179 patients for delirium using the 4 A's Test. Compared with the reference rater, the 4 A's Test had a sensitivity of 58% (95% confidence interval, 28-85) and specificity of 94% (95% confidence interval, 85-98). Postimplementation, 64% of nurses thought that the 4 A's Test improved their confidence in delirium detection, and 76% of nurses would consider routine 4 A's Test use.
CONCLUSIONS
The 4 A's Test demonstrated moderate sensitivity and high specificity to detect delirium in a real-world setting after cardiac surgery on the postoperative ward. A modified model of use with less frequent administration, along with increased engagement of the postoperative team, is recommended to improve early delirium detection on the cardiac surgery postoperative ward.
Identifiants
pubmed: 34243932
pii: S0022-5223(21)00876-X
doi: 10.1016/j.jtcvs.2021.05.031
pii:
doi:
Types de publication
Observational Study
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1151-1160.e8Subventions
Organisme : Medical Research Council
ID : G108/646
Pays : United Kingdom
Organisme : Medical Research Council
ID : MR/L023210/1
Pays : United Kingdom
Commentaires et corrections
Type : CommentIn
Type : CommentIn
Type : CommentIn
Informations de copyright
Copyright © 2021 The American Association for Thoracic Surgery. All rights reserved.