Long-term outcomes after enucleation or plaque brachytherapy of choroidal melanomas touching the optic disc.
Brachytherapy
Dosimetry
Enucleation
Juxtapapillary
Transpupillary thermotherapy
Uveal melanoma
Journal
Brachytherapy
ISSN: 1873-1449
Titre abrégé: Brachytherapy
Pays: United States
ID NLM: 101137600
Informations de publication
Date de publication:
Historique:
received:
23
03
2021
revised:
13
05
2021
accepted:
27
05
2021
pubmed:
14
7
2021
medline:
15
12
2021
entrez:
13
7
2021
Statut:
ppublish
Résumé
To investigate local and systemic outcomes after enucleation, brachytherapy with ruthenium-106, iodine-125, notched and non-notched plaques and transpupillary thermotherapy (TTT) of choroidal melanomas touching the optic disc. All patients treated for choroidal melanoma touching the optic disc at St. Erik Eye Hospital, Stockholm, Sweden between 1984 and 2015 (n = 165) were included. Retrospective clinicopathological data was collected and 3D dosimetry performed. Ninety-five patients (58 %) had been treated with ruthenium-106 brachytherapy, 21 (13 %) with iodine-125 brachytherapy and 49 (30 %) with enucleation. Median follow-up was 12.3 years. In simulations, some tumor areas were underdosed with non-notched plaques. Fifty of 116 patients (43 %) underwent a secondary brachytherapy (n = 5), enucleation (n = 29) or TTT (n = 16). In multivariate Cox Regressions, there were no significant differences in the risk for tumor progression or lack of regression between radioisotopes and notched and non-notched plaques. Adding TTT did not reduce the risk for a second treatment. The number of clock hours of circumpapillary tumor growth did not correlate to the risk for treatment failure or mortality. There were no significant differences in melanoma-related mortality for any treatment including enucleation. Kaplan-Meier disease-specific survival was 77 % at 5 years, 72 % at 10 years and 67 % at 20 years. Plaque brachytherapy of choroidal melanomas touching the optic disc entails a two to threefold increased risk for treatment failure. This risk is similar between radioisotopes, notched and non-notched plaque designs and if TTT is used or not. The high rate of treatment failure does not lead to increased mortality.
Identifiants
pubmed: 34253461
pii: S1538-4721(21)00431-1
doi: 10.1016/j.brachy.2021.05.162
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1245-1256Commentaires et corrections
Type : ErratumIn
Informations de copyright
Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.