Full-field hemocytometry. Forty years of progress seen through Clinical and Laboratory Hematology and the International Journal of Laboratory Hematology.
CBC
anemia
platelet parameters
red blood cell counting
white blood cells flags
Journal
International journal of laboratory hematology
ISSN: 1751-553X
Titre abrégé: Int J Lab Hematol
Pays: England
ID NLM: 101300213
Informations de publication
Date de publication:
Jul 2021
Jul 2021
Historique:
revised:
19
03
2021
received:
26
02
2021
accepted:
29
03
2021
entrez:
21
7
2021
pubmed:
22
7
2021
medline:
10
8
2021
Statut:
ppublish
Résumé
The extraordinary advances in clinical hematology, biology, and oncology in the last decades would not have been possible without discovering how to identify and count the cells circulating in the blood. For centuries, scientists have used slides, counting chambers (hemocytometers), and diluting and staining solutions for this task. Then, automated hemocytometry began. This science, now linked to the daily routine of laboratory hematology, has completed an overwhelming path over a few decades. Our laboratories today operate with versatile multiparameter systems, ranging from complex single-channel instruments to bulky continuous flow machines. In terms of clinical information obtained from a simple routine blood test, the full exploitation of their potential depends on the operators' imagination and courage. A comprehensive review of the scientific publications that have accompanied the development of hemocytometry from the 1950s to today would require entire volumes. More than seven hundred contributions that authors worldwide have published in Clinical and Laboratory Haematology until 2007 and then the International Journal of Laboratory Hematology are summarized. Such journals have represented and hopefully will continue to represent the privileged place of welcome for future scientific research in hemocytometry. Improved technologies, attention to quality, new reagents and electronics, information technology, and scientist talent ensure a more profound and deeper knowledge of cell properties: current laboratory devices measure and count even minor immature or pathological cell subpopulations. Full-field hemocytometry includes the analysis of nonhematic fluids, digital adds to the microscope, and the development of effective point-of-care devices.
Types de publication
Historical Article
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
7-14Informations de copyright
© 2021 John Wiley & Sons Ltd.
Références
Simson E. Wallace Coulter's life and his impact on the world. Int J Lab Hematol. 2013;35:230-236.
Simson E. The Launch of a New Journal. Int J Lab Hematol. 2007;29:1-2.
Davis BH, Jungerius B. and International Council for Standardization in Haematology technical report 1-2009: new reference material for haemiglobincyanide for use in standardization of blood haemoglobin measurements. Int J Lab Hematol. 2010;32:139-141.
England JM, Down MC. A comparison of methods for analysing red cell and platelet volume-distribution curves. Clin Lab Haematol. 1979;1:47-55.Mulhstin 2016
Simel D. Is the RDW-MCV classification of anaemia useful? Clin Lab Haematol. 1987;9:349-360.
Buttarello M. Laboratory diagnosis of anemia: are the old and new red cell parameters useful in classification and treatment, how? Int J Lab Hematol. 2016;38:123-132.
Vis JY, Huisman A. Verification and quality control of routine hematology analyzers. Int J Lab Hematol. 2016;38:100-109.
Tantanate C. Red blood cell and reticulocyte-related parameters in adult patients with β-thalassemia diseases. Int J Lab Hem. 2021;43:e12-e16.
Urrechaga E, Borque L, Escanero JF. (2013), Erythrocyte and reticulocyte indices in the assessment of erythropoiesis activity and iron availability. Int J Lab Hematol. 2013;35:144-149.
d'Onofrio G, Zini G, Ricerca BM, Mancini S, Mango G. Automated measurement of red blood cell microcytosis and hypochromia in iron deficiency and beta-thalassemia trait. Arch Pathol Lab Med. 1992;116:84-89.
ICSH. Proposed reference method for reticulocyte counting based on the determination of the reticulocyte to red cell ratio. The Expert Panel on Cytometry of the International Council for Standardization in Haematology. Clin Lab Haematol. 1998;20:77-79.
Van Hove L, Goossens W, Van Duppen V, Verwilghen RL. Reticulocyte count using thiazole orange. A flow cytometry method. Clin Lab Haematol. 1990;1990(12):287-299.
Buttarello M, Rauli A, Mezzapelle G. Reticulocyte count and extended reticulocyte parameters by Mindray BC-6800: reference intervals and comparison with Sysmex XE-5000. Int J Lab Hematol. 2017;39:596-603.
Noronha J, De Souza C, Vigorito A, et al. Immature reticulocytes as an early predictor of engraftment in autologous and allogeneic bone marrow transplantation. Clin Lab Haematol. 2003;25:47-54.
d'Onofrio G, Chirillo R, Zini G, Caenaro G, Tommasi M, Micciulli G. Simultaneous measurement of reticulocyte and red blood cell indices in healthy subjects and patients with microcytic and macrocytic anemia. Blood. 1995;85(3):818-823.
Brugnara C, Schiller C, Moran J. Reticulocyte hemoglobin equivalent (Ret He) and assessment of iron-deficient states. Clin Lab Haematol. 2006;28:303-308.
Sottiaux J-Y, Favresse J, Chevalier C, Chatelain B, Jacqmin H, Mullier F. Evaluation of a hereditary spherocytosis screening algorithm by automated blood count using reticulocytes and erythrocytic parameters on the Sysmex XN-series. Int J Lab Hematol. 2020;42:e88-e91.
Zini G, d'Onofrio G, Briggs C, et al. ICSH recommendations for identification, diagnostic value, and quantitation of schistocytes. Int J Lab Hematol. 2012;34:107-116.
Saigo K, Jiang M, Tanaka C, et al. Usefulness of automatic detection of fragmented red cells using a hematology analyzer for diagnosis of thrombotic microangiopathy. Clin Lab Haematol. 2002;24:347-351.
Lesesve J-F, Asnafi V, Braun F, Zini G. Fragmented red blood cells automated measurement is a useful parameter to exclude schistocytes on the blood film. Int J Lab Hematol. 2012;34:566-576.
Schapkaitz E, Mezgebe MH. Use of the automated fragmented red cell count for monitoring patients with thrombotic thrombocytopenic purpura. Int J Lab Hematol. 2016;38:e111-e113.
Karakioulaki M, Martinez M, Medinger M, Heim D, Passweg JR, Tsakiris DA. Peripheral blood schistocytes in the acute phase after allogeneic or autologous stem cell transplantation assessed by digital microscopy. Int J Lab Hematol. 2020;42:145-151.
Lewis SM, Wardle J, Cousins S, Skelly JV. Platelet counting-development of a reference method and a reference preparation. Clin Lab Haematol. 1979;1:227-237.
Rowan RM, Fraser C, Gray JH, McDonald GA. The Coulter Counter Model S Plus- the shape of things to come. Clin Lab Haematol. 1979;1:29-40.
Johannessen B, Roemer B, Flatmoen L, Just T, Aarsand AK, Scott CS. Implementation of monoclonal antibody fluorescence on the Abbott CELL-DYN Sapphire haematology analyser: evaluation of lymphoid, myeloid and platelet markers. Clin Lab Haematol. 2006;28:84-96.
Briggs C, Harrison P, Machin SJ. Continuing developments with the automated platelet count. Int J Lab Hematol. 2007;29:77-91.
Harrison P, Ault KA, Chapman S, et al. International Society of Laboratory Hematology Task Force for the Reference Platelet Count. An interlaboratory study of a candidate reference method for platelet counting. Am J Clin Pathol. 2001;115:448-459.
Giacomini A, Legovini P, Gessoni G, et al. Platelet count and parameters determined by the Bayer ADVIATM 120 in reference subjects and patients. Clin Lab Haematol. 2001;23:181-186.
Nkambule BB, Davison GM, Ipp H. The evaluation of platelet indices and markers of inflammation, coagulation and disease progression in treatment-naïve, asymptomatic HIV-infected individuals. Int J Lab Hematol. 2015;37:450-458.
Buttarello M, Mezzapelle G, Freguglia F, Plebani M. Reticulated platelets and immature platelet fraction: clinical applications and method limitations. Int J Lab Hematol. 2020;42:363-370.
Gioia M, Da Rin G, Manenti B, et al. Italian Working Group on Diagnostic Hematology of the Italian Society of Clinical Chemistry, Clinical Molecular Biology (WGDH-SIBioC). Multicenter evaluation of analytical performances of platelet counts and platelet parameters: carryover, precision, and stability. Int J Lab Hematol. 2020;42:552-564.
Park SH, Park CJ, Kim MJ, et al. Evaluation of parameters obtained from the Sysmex XN-2000 for predicting the recovery of the absolute neutrophil count and platelets after hematopoietic stem cell transplantation. Int J Lab Hematol. 2016;38:198-208.
Depoorter M, Goletti S, Latinne D, Defour J. Optimal flagging combinations for best performance of five blood cell analyzers. Int J Lab Hematol. 2015;37:63-70.
Furundarena JR, Sainz M, Uranga A, et al. Comparison of abnormal cell flagging of the hematology analyzers Sysmex XN and Sysmex XE-5000 in oncohematologic patients. Int J Lab Hematol. 2017;39:58-67.
Da Rin G, Vidali M, Balboni F, et al. Performance evaluation of the automated nucleated red blood cell count of five commercial hematological analyzers. Int J Lab Hematol. 2017;39:663-670.
Ayres LS, Sgnaolin V, Munhoz TP. Immature granulocytes index as early marker of sepsis. Int J Lab Hematol. 2019;41:392-396.
Gowans ID, Hepburn M, Clark DM, Patterson G, Rawlinson PSM, Bowen DT. The role of the Sysmex SE9000 immature myeloid index and Sysmex R2000 reticulocyte parameters in optimizing the timing of peripheral blood stem cell harvesting in patients with lymphoma and myeloma. Clin Lab Haematol. 1999;21:331-336.
Eilertsen H, Saether PC, Henriksson CE, Petersen A-S, Hagve T-A. Evaluation of the detection of blasts by Sysmex hematology instruments, CellaVision DM96, and manual microscopy using flow cytometry as the confirmatory method. Int J Lab Hematol. 2019;41:338-344.
Henriot I, Launay E, Boubaya M, et al. New parameters on the hematology analyzer XN-10 (SysmexTM) allow to distinguish childhood bacterial and viral infections. Int J Lab Hematol. 2017;39:14-20.
Frater JL, Zini G, d’Onofrio G, Rogers HJ. COVID-19 and the clinical hematology laboratory. Int J Lab Hematol. 2020;42(Suppl. 1):11-18.