One size may not fit all: patient-specific computational optimization of locking plates for improved proximal humerus fracture fixation.

Proximal humerus fracture finite element analysis fixation stability locking plate osteoporosis patient-specific implant

Journal

Journal of shoulder and elbow surgery
ISSN: 1532-6500
Titre abrégé: J Shoulder Elbow Surg
Pays: United States
ID NLM: 9206499

Informations de publication

Date de publication:
Jan 2022
Historique:
received: 05 02 2021
revised: 04 06 2021
accepted: 12 06 2021
pubmed: 24 7 2021
medline: 15 12 2021
entrez: 23 7 2021
Statut: ppublish

Résumé

Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures. FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males. The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men. The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.

Sections du résumé

BACKGROUND BACKGROUND
Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures.
METHODS METHODS
FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males.
RESULTS RESULTS
The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men.
CONCLUSION CONCLUSIONS
The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.

Identifiants

pubmed: 34298147
pii: S1058-2746(21)00549-8
doi: 10.1016/j.jse.2021.06.012
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

192-200

Informations de copyright

Copyright © 2021 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Auteurs

Jana Felicitas Schader (JF)

AO Research Institute Davos, Davos, Switzerland.

Dominic Mischler (D)

AO Research Institute Davos, Davos, Switzerland.

Jan Dauwe (J)

AO Research Institute Davos, Davos, Switzerland; Department of Trauma Surgery, UZ Leuven, Leuven, Belgium.

R Geoff Richards (RG)

AO Research Institute Davos, Davos, Switzerland.

Boyko Gueorguiev (B)

AO Research Institute Davos, Davos, Switzerland.

Peter Varga (P)

AO Research Institute Davos, Davos, Switzerland. Electronic address: peter.varga@aofoundation.org.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH